The DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Improved motion robustness of remote-PPG by using the blood volume pulse signature
Open accessAbstract
Remote photoplethysmography (rPPG) enables contact-free monitoring of the blood volume pulse using a color camera. Essentially, it detects the minute optical absorption changes caused by blood volume variations in the skin. In this paper, we show that the different absorption spectra of arterial blood and bloodless skin cause the variations to occur along a very specific vector in a normalized RGB-space. The exact vector can be determined for a given light spectrum and for given transfer characteristics of the optical filters in the camera. We show that this 'signature' can be used to design an rPPG algorithm with a much better motion robustness than the recent methods based on blind source separation, and even better than the chrominance-based methods we published earlier. Using six videos recorded in a gym, with four subjects exercising on a range of fitness devices, we confirm the superior motion robustness of our newly proposed rPPG methods. A simple peak detector in the frequency domain returns the correct pulse-rate for 68% of total measurements compared to 60% for the best previous method, while the SNR of the pulse-signal improves from - 5 dB to - 4 dB. For a large population of 117 stationary subjects we prove that the accuracy is comparable to the best previous method, although the SNR of the pulse-signal drops from + 8.4 dB to + 7.6 dB. We expect the improved motion robustness to significantly widen the application scope of the rPPG-technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although during exercise, the main potential errors are due to motion artifact, which complicates the use of the pulse oximeter and the accurate interpretation of the data [29,30,31]”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Self-citationDetecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. V. (2013) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2013.440 · Cited by 572
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 428
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Kumar, Y. V. B. V., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 221
Research works printed but not linked: 2
- Lewandowska M, 2011, Proc. FedCSIS, 18–21, 405
- Glass K A, 2004, Proc. 5th Int. Conf. ICA
Cited by
Sorted by citations
Items 401–491 of 491
Wang, L., Tao, X., Sun, L., & Shen, W. (2024) · SpringerBriefs in computer science · doi:10.1007/978-981-97-4550-0_4 · Cited by 1
PhysioSens1D-NET: A 1D Convolution Network for Extracting Heart Rate from Facial Videos
Anil, A. A., Karthik, S., Sivaprakasam, M., & Joseph, J. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782272 · Cited by 1
Nam, Y., Lee, J., Lee, J., Lee, H., Kwon, D., Yeo, M., Kim, S., Sohn, R., & Park, C. (2025) · Electronics · doi:10.3390/electronics14050890 · Cited by 1
Anil, A. A., Karthik, S., Sivaprakasam, M., & Joseph, J. (2025) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49660.2025.10890856 · Cited by 1
Toward Camera-PRV-Based Early Warning in Hospital ICU: A Pilot Study
Wang, H., Huang, J., Wang, G., Lou, J., Tancheng, Y., Huang, D., Lu, H., & Wang, W. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3566990 · Cited by 1
Channel attention pyramid network for remote physiological measurement
Zhang, J., Sun, H., Hu, Y., Zhu, G., Liu, F., Yan, B., Pu, J., Du, X., Liu, J., Liu, L., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-06107-5 · Cited by 1
Zarándy, Á., Földesy, P., Nagy, Á., Jánoki, I. G., Terbe, D., Siket, M., Szabó, M., & Varga, J. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9181040 · Cited by 1
A Comparative Study of rPPG-Based Pulse Rate Tracking Algorithms for Fitness ActivitiesPreprint
Zhu, Q., Wong, C.-W., Lazri, Z. M., Chen, M., Wu, M. H., & Wu, M. (2023) · doi:10.36227/techrxiv.22087751.v1 · Cited by 1
Vers le développement d'un capteur photoplétysmographique sans contact
Bobbia, S. (2019) · theses.fr (ABES) · doi:10.70675/a3c47f9fz5d34z4690za579zb07025c69b0f · Cited by 1
Gupta, A. R., Ravelo-García, A. G., & Morgado‐Dias, F. (2021) · doi:10.36227/techrxiv.14879784.v1
Dynamics Reconstruction of Remote Photoplethysmography
He, L., Alam, K. S., Ma, J., Povinelli, R. J., & Ahamed, S. I. (2022) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-99194-4_8
Peer Review #1 of "pyVHR: a Python framework for remote photoplethysmography (v0.1)"
(2022) · PeerJ Computer Science · doi:10.7287/peerj-cs.929v0.1/reviews/1
Peer Review #2 of "pyVHR: a Python framework for remote photoplethysmography (v0.1)"
(2022) · PeerJ Computer Science · doi:10.7287/peerj-cs.929v0.1/reviews/2
Measuring Physiological Parameters Under the Skin Using Visible/NIR Light
Raghuram, A., Zhao, Y., Maity, A. K., & Veeraraghavan, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00134-5
Peer Review #3 of "pyVHR: a Python framework for remote photoplethysmography (v0.1)"
(2022) · PeerJ Computer Science · doi:10.7287/peerj-cs.929v0.1/reviews/3
Peer Review #3 of "pyVHR: a Python framework for remote photoplethysmography (v0.2)"
(2022) · PeerJ Computer Science · doi:10.7287/peerj-cs.929v0.2/reviews/3
Gupta, A., Ravelo-García, A. G., & Morgado‐Dias, F. (2021) · doi:10.36227/techrxiv.14879784
Spatial-Channel Mixed Attention Based Network for Remote Heart Rate Estimation
Ling, B., Zhang, P., Qian, J., & Yang, J. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-18910-4_37
Kamshilin, A. A. (2022) · Bulletin of the Russian Academy of Sciences Physics · doi:10.3103/s1062873822700447
A Comparative Study of rPPG-Based Pulse Rate Tracking Algorithms for Fitness ActivitiesPreprint
Zhu, Q., Wong, C.-W., Lazri, Z. M., Chen, M., Wu, M. H., & Fu, C. (2023) · doi:10.36227/techrxiv.22087751
Heart Rate Estimation Using Remote Photoplethysmography and Deep Learning
Lee, R. J., Sivakumar, S., Lim, K. H., Chee, A. L. T., & Yon, J. L. S. (2023) · International Conference on Digital Applications, Transformation & Economy (ICDATE) · doi:10.1109/icdate58146.2023.10248803
Aprini, I., & Manullang, M. C. T. (2023) · JITEL (Jurnal Ilmiah Telekomunikasi Elektronika dan Listrik Tenaga) · doi:10.35313/jitel.v3.i3.2023.165-180
A Comparative Study of rPPG-Based Pulse Rate Tracking Algorithms for Fitness ActivitiesPreprint
Zhu, Q., Wong, C.-W., Lazri, Z. M., Chen, M., Fu, C., & Wu, M. H. (2024) · doi:10.36227/techrxiv.22087751.v2
Xu, J., Zhang, C., & Lv, Z. (2024) · International Conference on Signal Processing Systems (ICSPS) · doi:10.1117/12.3022956
Xiao, H., Li, Z., Xia, Z., Liu, T., Zhou, F., & Avolio, A. P. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4835616
Zhao, C., Sun, P., & Chen, Z. (2024) · Research Square · doi:10.21203/rs.3.rs-4534595/v1
Wrist Information Detection Sensor Based on Pinhole Imaging
Qi, H., Xiong, J., Cao, M., Lai, W., & Hu, Y. (2024) · IEEE photonics journal · doi:10.1109/jphot.2024.3435832
Approaches for Enhancement of Perception Through Snsor Design for Extreme Environment
Li, J., Li, N., Holderbaum, W., & Yao, W. (2024) · IEEE Conference on Cybernetics and Intelligent Systems · doi:10.1109/cis-ram61939.2024.10672968
A Comparison of Algorithms to Estimate Heart and Respiratory Rate from Face Video Processing
Ruíz-Espinosa, G., Jiménez-Ángeles, L., Guzmán, D. T., Rojas-Arce, J. L., & Marmolejo-Saucedo, J. A. (2024) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-031-67440-2_19
Zhao, C., & Chen, Z. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-8650-3_45
Non-contact Heart Rate and Respiratory Rate Estimation from Videos of the Neck
Zhang, T., Bolić, M., Farahani, M. H. D. A., Zadorsky, T., & Sabbagh, R. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781989
Toyama, K., Takahashi, M., & Tsumura, N. (2025) · Computational Optical Imaging and Artificial Intelligence in Biomedical Sciences · doi:10.1117/12.3039284
Camera-based cardio-respiratory monitoring across the full fitness cycle
Xiao, C. R., Tan, C., Song, L., Lu, H., & Wang, W. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adc364
Meng, F., Pan, X., & Huang, T. (2025) · Communications in computer and information science · doi:10.1007/978-981-96-4279-3_19
TRUST: Time-Domain Residual Unsupervised Stability Technique for Improved Heart Rate Estimation
Ahmad, S., Bano, S., Chanda, S., Vipparthi, S. K., & Murala, S. (2025) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv61041.2025.00398
PULSE: Physiological Understanding with Liquid Signal Extraction
Ahmad, S., Bano, S., Verma, S., Rawat, Y. S., Chanda, S., Vipparthi, S. K., & Murala, S. (2025) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv61041.2025.00449
Privacy-preserving remote heart rate estimation using Block-wise Frequency Domain Transformation
Huang, H., Ou, W., & Xiong, J. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107893
Remote heart rate measurement based on spatial–temporal self-attention
Sun, N., Wang, N., Liu, J., Chai, L., & Sun, H. (2025) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2025.110557
Cali-rPPG: A Unified Uncertainty-Aware Framework for Remote Photoplethysmography
Shi, T., Sun, Y., Ye, S., & Wang, T. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-0033-8_18
Investigating the Effectiveness of Filter in rPPG Methods Across Various Skin Tones
ASLAMI, F., & Sripian, P. (2025) · International Journal of Affective Engineering · doi:10.5057/ijae.ijae-d-24-00035
Non-Contact Pulse Rate Detection Methods Based on Adaptive Projection Plane
Fu, C., Zhang, Y., Pan, J., He, X., & Hong, H. (2025) · Mathematics · doi:10.3390/math13172749
Noncontact Vital Sign Measurement Using Video Data: A Review
Lakshmi, D. R., & Swathi, K. (2025) · Springer proceedings in mathematics & statistics · doi:10.1007/978-3-031-84513-0_1
Phys-Vim: State space model for remote physiological measurement
Zhiyuan, C., Wang, H., Han, Y., Lv, J., & Li, B. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.131405
Yang, K., Long, N., Ke, W., Lam, C., Tan, T., Yu, Z., & Sun, Y. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3603308
TA2N: Fast and Accurate Temporal Attention 2D Network for Remote Photoplethysmography
Huang, K.-C., Hsu, H.-J., & Chen, L. H. (2025) · IEEE International Conference on Multimedia Information Processing and Retrieval (MIPR) · doi:10.1109/mipr67560.2025.00065
Li, J., & Peng, J. (2025) · Applied Soft Computing · doi:10.1016/j.asoc.2025.114328
AI-Based Remote Photoplethysmography: Benchmarking on Realistic Datasets
Micallef, N., Camilleri, K. P., Grech, N., Calleja‐Agius, J., & Falzon, O. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253069
Dual-Stream Fusion for Advanced Spatio-Temporal Analysis in Remote Photoplethysmography
Liu, B., Liu, J., Wang, Y., & Kato, J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253025
Premature infant monitoring in neonatal intensive care units
Liao, C., Zeng, Y., Wang, Q., Pan, L., Song, X., Yang, J., Brinker, A. C. D., Lu, H., Zhong, N., & Wang, W. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26586-0.00009-0
Monitoring of deterioration in intensive care units patients
Wang, H., Huang, J., Wang, G., Lou, J., Brinker, A. C. D., Lu, H., Zhong, N., & Wang, W. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26586-0.00003-x
Fitness cardiac monitoring for assessing cardiovascular functions
Xiao, C., Xu, M., Song, L., Brinker, A. C. D., Lu, H., Zhong, N., & Wang, W. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26586-0.00013-2
PPG signal estimation method based on improved GRU encoder-decoder architecture
Lin, D., Kou, D., & Wu, Y. (2025) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icia64617.2025.11277666
Anil, A. A., Karthik, S., Poppen, C. D. J., Sivaprakasam, M., & Joseph, J. (2025) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2025.3645022
Zhang, H., Wang, X., Dang, P., Ma, C., Liu, S., Xiong, Z., & Liu, C. (2025) · Applied Soft Computing · doi:10.1016/j.asoc.2025.113593
Exploiting optical flow guidance for motion-robust remote physiological measurements
Zhang, Y., Lu, W., Xu, J., Zhang, R., & Wei, J. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.109300
Multimodal Remote Heart Rate Estimation via Spatio-Temporal Transformers and Adaptive Fusion
Kim, H. R., Lee, S.-H., Sohn, M., Kim, J., & Park, H. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3660453
Zhang, W., Zhu, D., Zeng, H., & Yang, L. (2026) · Lecture notes in computer science · doi:10.1007/978-981-95-6960-1_1
Retrieval Of Blood Volume Pulse Waveforms Using Multispectral Face Video Data
Tyler, J., Khan, I. A., Thapa, S., Abbott, A. L., & Sarkar, A. (2025) · IEEE International Conference on Image Processing Workshops (ICIPW) · doi:10.1109/icipw68931.2025.11386220
Remote Heart Rate Measurement Based on Near Infrared Prior Information
Shao, H., & Hu, C. (2025) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw69036.2025.00062
Recovering Pulse Waves From Video Using Deep Unrolling and Deep Equilibrium Models
Shenoy, V., Lohit, S., Mansour, H., Chellappa, R., & Marks, T. K. (2026) · IEEE Transactions on Image Processing · doi:10.1109/tip.2026.3671653
Designing Reproducible Test Environments for rPPG: A System for Camera Sensor Response Validation
van Putten, L. D., Veleslavov, I., Ahmed, A., Mathieu, A., & Wegerif, S. (2026) · Lights · doi:10.3390/lights2020003
Reliability-Aware Weighted Multi-Scale Spatio-Temporal Maps for Heart Rate Monitoring
Bairagi, A., Dey, R., Manna, S., & Pal, U. (2026) · Proceedings - International Conference on Image Processing · doi:10.1109/icip61757.2026.11630057
Remote photoplethysmography measurement and filtering using deep learning based methods
Botina-Monsalve, D. (2022) · theses.fr (ABES) · doi:10.70675/c0d1594az55a6z46ebzb3f5zc824513fd847 · Cited by 1
Development of trustworthy intelligent avatars in virtual immersion
Hadadi, A. (2024) · theses.fr (ABES) · doi:10.70675/8d13bedfz1589z4486zbc0bzdf696c7a3007
PDH-Net: A Parallel Dual-Branch Hybrid Network for Camera-Based Blood Oxygen Saturation Measurement
Gao, Q., Jiao, X., Qi, L., Xu, L., & Qian, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3682807
Illumination-Invariant Normalization for Robust rPPG Extraction
An, B. S., Park, S. H., Kim, Y. J., Song, Y. R., Cho, G. J., & Lee, E. C. (2026) · Electronics · doi:10.3390/electronics15081683
Video-Based Heart Rate Estimation with Angle-Guided ROI Optimization and Graph Signal Denoising
Pei, G., Ning, J., Shen, B., Zhu, Y., & Hu, M. (2026) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp55912.2026.11463254
Alihosseini, N., Koochekian, A., Fazilati, F., Farsani, M. E., Rajabi, M. Z., Farahani, M. A., Mansourian, M., Zadeh, A. S., & Marateb, H. R. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-44638-2.00017-8
Rhythmguassian: Repurposing Generalizable Gaussian Model for Remote Physiological Measurement
Lu, H., Zhang, Y., Tang, Fu, B., Ge, W., Wei, W., Wu, K., & Chen, Y.-C. (2025) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51701.2025.01932
Ying, C., Yang, H., 葛介艺, Sun, Z., Cheng, X., Ren, K., & Li, X. (2025) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51701.2025.00874 · Cited by 1
Feature-Disentangling RGB-NIR Fusion Network for Remote Driver Physiological Measurement
Bouraffa, T., Wang, Z., & Strüber, D. (2026) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv61042.2026.00071
Zhang, B., Gao, Y., & Yao, Y. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110523
LQ-rPPG: A label-quantized coarse-to-fine learning framework for remote physiological measurement
Lee, J. S., Noh, S., Sung, C., & Myung, H. (2026) · Expert Systems with Applications · doi:10.1016/j.eswa.2026.132977
Berezhnyi, I., & Nakonechny, A. (2026) · Measuring Equipment and Metrology · doi:10.23939/istcmtm2026.02.102
Luo, Y., Sun, Z., Yang, H., Geng, W., Chen, Y., & Li, X. (2026) · International Conference on Multimedia Retrieval · doi:10.1145/3805622.3810868
方木鱼, Kuang, H., Ma, X., & Liu, X. J. (2026) · International Conference on Image, Signal Processing and Pattern Recognition (ISPP) · doi:10.1109/ispp69262.2026.11542973
PhysQual: A quality-aware learning framework for robust remote photoplethysmography
Mohamad, F., Zulkernine, F. H., & Sears, K. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100683 · Cited by 1
Okafor, O., Adama, D. A., Dangana, M., & Vinkemeier, D. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3706851
Shahmirzadi, D., Wang, W.-F., & Rahmani, A. M. (2026) · Array · doi:10.1016/j.array.2026.100969
Adaptive Pulse Extraction Via Filter Bank Common Spatial Pattern for Remote Photoplethysmography
Lee, J. G., Woo, J., & Joo, H. (2026) · IEEE Access · doi:10.1109/access.2026.3712776
Lee, J., Kim, H., Lee, W., Ahn, B., park, S., Lee, H., Jung, J., Shin, J., Jeong, H., Kim, G., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-8924159/v1
Feasibility of heart rate monitoring in hemodialysis patients using visible imaging: a pilot study
Debnath, U., Srestha, S. D., & Kim, S. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1909505
Heart Rate Sensing Using Adaptive Motion-Compensated Contactless rPPG From Facial Imaging
Yi, Y., Yang, X., Zou, Y., Cai, F., Sun, J. C., & Yao, K. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3724615
Park, D., Jo, H., & Kwon, N. K. (2026) · Electronics · doi:10.3390/electronics15173862
rPPG-Guided Multi-Task Cascaded Learning for Joint Heart Rate and SpO₂ Estimation
Li, J., Jiang, X., Tu, X., Gao, Y., & Huang, H. (2026) · IEEE Access · doi:10.1109/access.2026.3735373
Park, J., Oh, S., & Lee, S. J. (2026) · Sensors · doi:10.3390/s26196105
Exploring 3D Convolutional Neural Networks for Remote Photoplethysmography Waveform Extraction
Sturekova, J., Sýkora, P., Šúchalová, S., & Kamencay, P. (2026) · International Conference Radioelektronika · doi:10.1109/radioelektronika71189.2026.11726444
Metadata
- Authors
- de Haan, G., & van Leest, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-08-27
- Volume
- 35
- Issue
- 9
- Pages
- 1913-1926
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2044935899
- Cited by
- 491
- References
- 16
- Citations by year
- 2026: 39 · 2025: 77 · 2024: 67 · 2023: 56 · 2022: 70 · 2021: 42 · 2020: 28 · 2019: 32 · 2018: 34 · 2017: 26 · 2016: 12 · 2015: 8
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- TU/e Research Portal (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- remote photoplethysmography, blood volume pulse, motion robustness, RGB color space, pulse rate detection, signal-to-noise ratio, non-contact vital sign monitoring, exercise monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review