The DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Improved motion robustness of remote-PPG by using the blood volume pulse signature
Open accessAbstract
Remote photoplethysmography (rPPG) enables contact-free monitoring of the blood volume pulse using a color camera. Essentially, it detects the minute optical absorption changes caused by blood volume variations in the skin. In this paper, we show that the different absorption spectra of arterial blood and bloodless skin cause the variations to occur along a very specific vector in a normalized RGB-space. The exact vector can be determined for a given light spectrum and for given transfer characteristics of the optical filters in the camera. We show that this 'signature' can be used to design an rPPG algorithm with a much better motion robustness than the recent methods based on blind source separation, and even better than the chrominance-based methods we published earlier. Using six videos recorded in a gym, with four subjects exercising on a range of fitness devices, we confirm the superior motion robustness of our newly proposed rPPG methods. A simple peak detector in the frequency domain returns the correct pulse-rate for 68% of total measurements compared to 60% for the best previous method, while the SNR of the pulse-signal improves from - 5 dB to - 4 dB. For a large population of 117 stationary subjects we prove that the accuracy is comparable to the best previous method, although the SNR of the pulse-signal drops from + 8.4 dB to + 7.6 dB. We expect the improved motion robustness to significantly widen the application scope of the rPPG-technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although during exercise, the main potential errors are due to motion artifact, which complicates the use of the pulse oximeter and the accurate interpretation of the data [29,30,31]”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Self-citationDetecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. V. (2013) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2013.440 · Cited by 572
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 428
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Kumar, Y. V. B. V., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 221
Research works printed but not linked: 2
- Lewandowska M, 2011, Proc. FedCSIS, 18–21, 405
- Glass K A, 2004, Proc. 5th Int. Conf. ICA
Cited by
Sorted by citations
Items 301–400 of 491
Remote Respiration Measurement with RGB Cameras: A Review and Benchmark
Boccignone, G., Cuculo, V., D’Amelio, A., Grossi, G., Lanzarotti, R., & Patania, S. (2025) · ACM Computing Surveys · doi:10.1145/3771763 · Cited by 5
Doctor Robots: Design and Implementation of a Heart Rate Estimation Algorithm
Göngör, F., & Tutsoy, Ö. (2022) · International Journal of Social Robotics · doi:10.1007/s12369-022-00888-9 · Cited by 4
Robust RPPG Method Based on Reference Signal Envelope to Improve Wave Morphology
Sun, L., Wang, L., Shen, W., Liu, C., & Bai, F. (2023) · Electronics · doi:10.3390/electronics12132813 · Cited by 4
Liu, T., Xiao, H., Sun, Y., Zhao, A., Zuo, K., Wen, H., Li, Z., & Li, Z. (2024) · Digital Signal Processing · doi:10.1016/j.dsp.2024.104525 · Cited by 4
Buyung, R. A., Bustamam, A., & Ramazhan, M. R. S. (2024) · Sensors · doi:10.3390/s24237537 · Cited by 4
Xu, B., Madhu, H., Kulkarni, R., Mestha, L. K., Kyal, S., & Pennington, G. (2016) · IEEE Healthcare Innovations and Point of Care Technologies Conference (HI-POCT) · doi:10.1109/hic.2016.7797732 · Cited by 4
Eaton, A., Vincely, V. D., Lloyd, P., Hugenberg, K., & Vishwanath, K. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2252629 · Cited by 4
Frame Registration for Motion Compensation in Imaging Photoplethysmography
Iakovlev, D., Hu, S., & Dwyer, V. M. (2018) · Sensors · doi:10.3390/s18124340 · Cited by 4
VitalCamSet - a dataset for Photoplethysmography Imaging
Blocher, T., Krause, S., Zhou, K., Zeilfelder, J., & Stork, W. (2019) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2019.8705999 · Cited by 4
Camera-based blood pressure monitoring
Natarajan, K., Yavarimanesh, M., Wang, W., & Mukkamala, R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00014-7 · Cited by 4
Heart Rate Estimation by PCA with LSTM from Video-based Plethysmography Under Periodic Noise
Traivinidsreesuk, C., Yodrabum, N., Chaikangwan, I., & Titijaroonroj, T. (2022) · International Computer Science and Engineering Conference · doi:10.1109/icsec56337.2022.10049315 · Cited by 4
Cantrill, S., Ahmedt‐Aristizabal, D., Petersson, L., Suominen, H., & Armin, M. A. (2024) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw63382.2024.00040 · Cited by 4
Continual Test-Time Adaptation for Robust Remote Photoplethysmography Estimation
Lee, H., Lee, H., Lee, B. H., & Chun, S. Y. (2025) · IEEE Access · doi:10.1109/access.2025.3554508 · Cited by 3
Li, Z., Wu, X., Casado, C. Á., Lindholm, V., Mikkonen, K., Xia, Z., Feng, X., & López, M. B. (2026) · Neurocomputing · doi:10.1016/j.neucom.2026.132877 · Cited by 7
Zeb, S., Lian, X., Mumtaz, W., & Wang, K. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109787 · Cited by 4
Seconds Matter: Rapid Non-Contact Monitoring of Heart and Respiratory Rate from Face Videos
Khan, T., Boda, P., Björklund, A., & Malmberg, S. (2026) · Sensors · doi:10.3390/s26051506 · Cited by 5
Bi, S., Wang, H., & Zhang, S. (2024) · Sensors · doi:10.3390/s24113346 · Cited by 3
Xiao, H., Li, Z., Xia, Z., Liu, T., Zhou, F., & Avolio, A. P. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106736 · Cited by 3
Improved Remote Photoplethysmography Using Machine Learning-Based Filter Bank
Lee, J. G., Joo, H., & Woo, J. (2024) · Applied Sciences · doi:10.3390/app142311107 · Cited by 3
Can Camera-PPG Imaging be Used to Measure Perfusion Index?
Xu, Z., Huang, Y., Zhao, N., Huang, J., Lu, H., & Wang, W. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781667 · Cited by 3
Rao, B., Fang, R., Zhao, C., & Bai, J. (2025) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2025.104326 · Cited by 3
Momeni, M., Wuthe, S., Mølmer, M. B., Svendsen, E. L., Brabrand, M., Biesenbach, P., & Teichmann, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3553368 · Cited by 3
Heart Rate Estimation from Facial Video Sequences using Fast Independent Component Analysis
Biradar, H. G., & Gawande, J. P. (2022) · National Conference on Communications · doi:10.1109/ncc55593.2022.9806810 · Cited by 3
Research on Non-contact Multi-person Heart Rate Measurement Method for Intelligent Education
Lian, Y., Ryu, J., Wang, S., Liang, S., & Kyongil, O. (2022) · International Conference on Information Science, Parallel and Distributed Systems (ISPDS) · doi:10.1109/ispds56360.2022.9874225 · Cited by 3
Non-contact Measurement of Physiological Parameters Based on Contrastive Learning
Sun, W., & Sun, Q. (2022) · IEEE International Conference on Frontiers Technology of Information and Computer (ICFTIC) · doi:10.1109/icftic57696.2022.10075092 · Cited by 3
An Accurate Non-Contact Photoplethysmography via Active Cancellation of Reflective Interference
Tong, Y., Huang, Z., Qiu, F., Wang, T., Wang, Y., Qin, F., & Yin, M. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3443988 · Cited by 3
Moustafa, M., Farooq, M. A., Elrasad, A., Lemley, J., & Corcoran, P. (2024) · IEEE Access · doi:10.1109/access.2024.3472508 · Cited by 3
Remote heart rate measurement based on video color magnification and spatiotemporal self-attention
Sun, N., He, P., Liu, J., Chai, L., Wu, C., & Liu, X. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107677 · Cited by 3
Convolutional Neural Network Approach for Estimating Physiological States Involving Face Analytics
Qayyum, A., Khan, M. K. A. A., Mazher, M., Suresh, M., Jamal, D. N., & Chung, T. D. (2019) · IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS) · doi:10.1109/i2cacis.2019.8825048 · Cited by 3
Modified Camera Setups for Day-and-Night Pulse-rate Monitoring
Wang, W., Vosters, L., & Brinker, A. C. D. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630497 · Cited by 3
Adaptive non-contact robust heart rate detection method under head rotation motion
Batubayaer, O.-Y., Zhao, Y., Kong, L., Dong, L., Liu, M., & Hui, M. (2022) · Acta Physica Sinica · doi:10.7498/aps.71.20211634 · Cited by 3
Short Window Network for Remote Heart Rate Measurement
Zhou, K., Krause, S., Blocher, T., & Stork, W. (2021) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi52183.2021.00039 · Cited by 3
Wearable Photoplethysmography-based Bipolar Disorder Detection
Lyu, Q., Zhang, X., Ding, X., & Chen, J. (2024) · doi:10.1145/3709026.3709099 · Cited by 2
Yu, L., Fei, J., Liu, X., Yao, Y., Zhao, J. Q., Wang, G., & Li, X. (2025) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49660.2025.10888739 · Cited by 2
Smartphone-based measurement of cardiovascular healthcare: Advances and applications
Chen, X., Chen, J., Xu, H., He, T., Fridenfalk, M., & Lv, Z. (2025) · Measurement · doi:10.1016/j.measurement.2025.117347 · Cited by 3
Ma, J.-R., Jia, R., Zhang, M.-Q., Jiang, M.-X., & Sun, H.-M. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3560707 · Cited by 2
Zhang, W., Xiong, Q., Zhou, W., Zhou, G., Tang, J., & Peng, L. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108982 · Cited by 2
Ma, J.-R., Jia, R., Zhang, M., Jiang, M.-X., & Sun, H.-M. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.113501 · Cited by 2
HemNet: Hemoglobin-Assistant Network for Video-Based Remote Photoplethysmography Measurement
Wu, R., Zhuo, W., Shi, J., Liu, X., Shen, L., Gong, Y., & Zhao, G. (2026) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2025.3650742 · Cited by 2
Debnath, U., & Kim, S. (2026) · PLoS ONE · doi:10.1371/journal.pone.0340097 · Cited by 2
Tian, Y., Li, S., Zhu, Y., Elgendi, M., & Lam, E. Y. M. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02386-y · Cited by 2
Kamerabasierte Erfassung von Vitalparametern
Haist, T. J., Reichert, C. C., Würtenberger, F., Lachenmaier, L., & Faulhaber, A. (2019) · tm - Technisches Messen · doi:10.1515/teme-2019-0019 · Cited by 2
An Improved Approach to the Performance of Remote Photoplethysmography
Sheng, Y., Zeng, W., Hu, Q., Ou, W., Xie, Y. R., & Li, J. (2022) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.027985 · Cited by 2
Lyu, F., Zhu, Y., Chen, S., & Wang, L. (2022) · International Conference on Computer Application and Information Security (ICCAIS) · doi:10.1117/12.2637576 · Cited by 2
Hallucinated Heartbeats: Anomaly-Aware Remote Pulse Estimation
Speth, J., Vance, N., Sporrer, B., Niu, L., Flynn, P. J., & Czajka, A. (2023) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0011781700003414 · Cited by 2
Frequency Tracker for Unsupervised Heart Rate Estimation
Zhalbekov, I., Beynenson, L., Trushkov, A., Bulychev, I., & Yin, W. (2023) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw59228.2023.00641 · Cited by 2
Remote Photoplethysmography: Digital Disruption in Health Vital Acquisition
Monika, Kumar, H., Kaushal, S., & Garg, V. (2023) · Springer eBooks · doi:10.1007/978-3-031-38036-5_12 · Cited by 2
Non-contact heart rate measurement using low-cost RGB camera under complex light conditions
Wang, H., & Zhang, S. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-19115-w · Cited by 2
Díaz–González, C. D. L. M., Pérez-Bello, C., la Rosa-Hormiga, M. D., González, J. J., & Reyes-Noha, M. D. L. M. (2024) · Healthcare · doi:10.3390/healthcare12090940 · Cited by 2
Zhang, Q., Lin, X., Zhang, Y., Liu, X., & Cai, F. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-19697-5 · Cited by 2
Borik, Š., Wu, H., Shelley, K. H., & Alian, A. A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106574 · Cited by 2
Bi-level weighted mixed-domain self-attention network for non-contact heart rate estimation
Ren, W., Chen, Y., Zhang, D., & Karimi, H. R. (2024) · Knowledge-Based Systems · doi:10.1016/j.knosys.2024.112262 · Cited by 2
rPPG-HiBa:Hierarchical Balanced Framework for Remote Physiological Measurement
Wang, Y., Lü, H., Chen, Y.-C., Kuang, L., Zhou, M., & Deng, S. (2024) · ACM International Conference on Multimedia (ACM MM) · doi:10.1145/3664647.3680986 · Cited by 2
WTC3D: An Efficient Neural Network for Noncontact Pulse Acquisition in Internet of Medical Things
Zhao, C., Cao, P., Hu, M., Huang, B., Chen, H., & Li, J. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3485749 · Cited by 2
Zhu, D., Zhang, W., Zeng, H., Liu, X., Long, Y., & Zheng, J. (2024) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm62325.2024.10822457 · Cited by 2
Scherpf, M., Ernst, H., Malberg, H., & Schmidt, M. U. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110571 · Cited by 2
Self-Adaptive Illumination Enhancement for Neonatal Remote Physiological Measurement in NICUs
Yang, K., Long, N., Cao, K., Huang, B., Chen, Z., Zeng, Y., Tan, T., Shan, C., Jiang, J., & Sun, Y. (2025) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2025.3604088 · Cited by 2
Color Intensity: A Study of RPPG Algorithm for Heart Rate Estimation
Sinhal, R. A., Singh, K. R., & Gupta, K. O. (2021) · International Conference on Computational Performance Evaluation (ComPE) · doi:10.1109/compe53109.2021.9752363 · Cited by 2
A real-time heart rate estimation framework based on a facial video while wearing a mask
Ryu, J., Hong, S., Liang, S., Pak, S., Zhang, L., Wang, S., & Lian, Y. (2022) · Technology and Health Care · doi:10.3233/thc-220322 · Cited by 2
Remote Heart Rate Estimation in Low-Light Environments Based on Eulerian Video Magnification
Liu, L., & Wang, G. (2022) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei56279.2022.9979977 · Cited by 2
Simulating cardiac signals on 3D human models for photoplethysmography development
Wang, D., & Chahl, J. (2024) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1266535 · Cited by 2
Preserving shape details of pulse signals for video-based blood pressure estimation
Han, X., Yang, X., Fang, S., Chen, Y., Chen, Q., Li, L., & Song, R. (2024) · Biomedical Optics Express · doi:10.1364/boe.516388 · Cited by 2
Kobayashi, L., Chuck, C. C., Kim, C. K., Luchette, K. R., Oster, A., Merck, D. L., Kirenko, I. O., van Zon, K., Bartula, M., Rocque, M., et al. (2023) · IEEE Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) · doi:10.1109/uemcon59035.2023.10316088 · Cited by 1
Zhang, L., Ren, J., Zhao, S., & Wu, P. (2024) · Sensors · doi:10.3390/s24216791 · Cited by 1
Li, J., & Yao, W. (2024) · International Conference on Automation and Computing (ICAC) · doi:10.1109/icac61394.2024.10718764 · Cited by 1
STSPhys: Enhanced Remote Heart Rate Measurement With Spatial-Temporal SwiftFormer
Kim, H. R., Lee, S.-H., Sohn, M., Kim, J., & Park, H. (2024) · IEEE Signal Processing Letters · doi:10.1109/lsp.2024.3522854 · Cited by 1
NeuralPOS: Physiological Measurement via Remote Photoplethysmography for Driver Monitoring
Jiang, T., Ma, Y., Zhao, X., Ji, X., & Liu, Y. (2024) · CAA International Conference on Vehicular Control and Intelligence (CVCI) · doi:10.1109/cvci63518.2024.10830052 · Cited by 1
Heart Rate Estimation by Near-Infrared-iPPG Considering Motion Artifacts During Sleep
Emori, T., Ohhira, T., & Hashimoto, H. (2024) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon55916.2024.10905844 · Cited by 1
Diffusion-Phys: noise-robust heart rate estimation from facial videos via diffusion models
Jeong, Y.-H., & Choi, Y.-S. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00472-w · Cited by 1
Pruning remote photoplethysmography networks using weight-gradient joint criterion
Zhao, C., Zhang, S., Cao, P., Cheng, S., & Zhang, J. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.127623 · Cited by 1
Robust Heart Rate Measurement Against Uneven Illuminations Using an RGB-D Camera
Yu, G. W., Yang, C., Wang, W., Gao, H., Xiao, Z., Li, J., & Liu, C. (2025) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-025-00950-7 · Cited by 1
An Adaptive Knowledge Distillation Framework for Short-Form Remote Physiological Measurement
Zhang, Y., Lu, W., Xu, J., Zhang, R., & Wei, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3580874 · Cited by 1
Photoplethysmography imaging to assess facial perfusion under simulated hypovolemia
Borik, Š., Gilmore, M. L., Fiol, A. G., Biondi, J. W., Wu, H., Shelley, K. H., & Alian, A. A. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adece3 · Cited by 1
Remote PPG Measurement Using a Synergistic Time-Frequency Network
Li, Y., He, Q., Yang, Y., Chu, Y., Hu, Y., Wu, Z., Bai, X., Zhang, X., Liu, W., & Shen, H. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3589712 · Cited by 1
Yang, J., Zhu, C., & Wu, R. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3597997 · Cited by 1
Contactless Hemodynamic Monitoring Based on Multi-Scale Gaussian Filtering via Imaging PPG
Tong, Y., Huang, Z., Qiu, F., Wu, C., Tao, X., Huang, W. F., & Qin, F. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3605591 · Cited by 1
PhysMamba: Synergistic State Space Duality Model for Remote Physiological Measurement
Yan, Z., Zhong, Y., Xu, H., Zhang, W., Yi, S., Kang, W., & Shu, L. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-04555-3_11 · Cited by 1
MMDrive: Multi-Modal Remote Physiological Signal Measurement Dataset for Driver Status Monitoring
Choi, J., & Lee, S. J. (2025) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw67362.2025.00567 · Cited by 1
Balancing cardiac privacy with quality in video recordings
Elgendi, M., Yu, A., Bhutani, S., & Menon, C. (2025) · Communications Medicine · doi:10.1038/s43856-025-01175-0 · Cited by 1
Li, Y., Wang, J., Pan, C., Pang, J., Chen, Y., & Li, K. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253951 · Cited by 1
Liu, C., Liu, Z., Yao, H., Li, S., Zhang, X., Wu, G., & Chen, S. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108983 · Cited by 1
Oulu Remote-photoplethysmography Presentation Attacks Database (OR-PAD)
Savić, M., & Zhao, G. (2025) · International Journal of Computer Vision · doi:10.1007/s11263-025-02588-z · Cited by 1
Qaadan, S., Jayyousi, G. A. A., & Alkhalaileh, A. (2026) · Electronics · doi:10.3390/electronics15010218 · Cited by 1
Local heating induces an increase in the pulse wave velocity in peripheral vessels
Kamshilin, A. A., Podolyan, N. P., Mizeva, I. A., Mamontov, O. V., Zaytsev, V. V., Vasilieva, M., Кащенко, В. А., Sakovskaia, A. V., Dolotovskaya, P. M., Борисович, М. Н., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-40041-4 · Cited by 1
Video-based SpO2 estimation in multi-scenarios via wavelength-guided image feature enhancement
Pei, G., Tan, X., Ning, J., Zhu, Y., & Hu, M. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109917 · Cited by 1
PhysVLM: Vision-Language Model for Generalizable Multitask Remote Physiological Measurement
Gao, J., San, I. W., Luo, X., Chen, Z., Yu, Z., Tan, T., & Sun, Y. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3671908 · Cited by 1
Detecting stress from videos via intra-subject and inter-subject learning
Ding, Y., Dai, Y. Q., Cao, L., Tian, J., Lin, Z., & Feng, L. (2026) · Health Information Science and Systems · doi:10.1007/s13755-026-00450-1 · Cited by 1
Spatial Alignment and Temporal Matching Adapter for Video-Radar Remote Physiological Measurement
Liang, Q., Geng, R., Chen, J., Wang, H., Chen, Y., & Hu, Y. (2025) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51701.2025.00807 · Cited by 2
Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removal
Kaur, G., Lakshminarayanan, V., & Saini, S. (2026) · Biomedical Optics Express · doi:10.1364/boe.599752 · Cited by 1
A study of the effect of subject motion to pulse rate estimation
Xu, B., Madhu, H., & Mestha, L. K. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591826 · Cited by 1
Moghaddam, G. K., & Lowe, C. R. (2018) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-030-01557-2_3 · Cited by 1
Vision-based HRV Measurement for HRI Study
Shibata, Y., Tsuji, K., Loo, C. K., Sun, G., Yamazaki, Y., & Hashimoto, T. (2018) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2018.8628908 · Cited by 1
Waqar, M., Reyer Zwiggelaar, A., & Tiddeman, B. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-61125-5_10 · Cited by 1
Generalized Eigenvalue Decomposition Applied to Estimation of Spatial rPPG Distribution of Skin
Macwan, R., Benezeth, Y., & Mansouri, A. (2021) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-021-01025-3 · Cited by 1
DelNet based Systolic Peak Delineation in Remote PPG Signal from Facial Video Frames
Das, M., Bhuyan, M. K., & Sharma, L. N. (2023) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt56998.2023.10306618 · Cited by 1
Remote Heart Rate Estimation Based on ROI Extraction
Jian, W., Zhang, Y., & Hu, K. (2023) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei60920.2023.10373358 · Cited by 1
Adaptive projection plane and feature selection for robust non-contact heart rate detection
Zhang, Y., Fu, C., Zhang, L., & Hong, H. (2024) · International Conference on Signal Processing Systems (ICSPS) · doi:10.1117/12.3023091 · Cited by 1
Demirhan, H., & Ricanek, K. (2023) · Congress in Computer Science, Computer Engineering, and Applied Computing (CSCE) · doi:10.1109/csce60160.2023.00228 · Cited by 1
A robust heart rate measurement framework based on videos
Dong, B., Liu, Y., & Wang, X. (2024) · Conference on Frontiers in Optical Imaging and Technology: Imaging Detection and Target Recognition · doi:10.1117/12.3018792 · Cited by 1
Heart Rate Estimation from Facial Videos Using 2D Convolution Neural Network
Mohamed, O., Mohamed, A. K., & Alenany, A. (2024) · Intelligent Methods, Systems, and Applications (IMSA) · doi:10.1109/imsa61967.2024.10652792 · Cited by 1
Metadata
- Authors
- de Haan, G., & van Leest, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-08-27
- Volume
- 35
- Issue
- 9
- Pages
- 1913-1926
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2044935899
- Cited by
- 491
- References
- 16
- Citations by year
- 2026: 39 · 2025: 77 · 2024: 67 · 2023: 56 · 2022: 70 · 2021: 42 · 2020: 28 · 2019: 32 · 2018: 34 · 2017: 26 · 2016: 12 · 2015: 8
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- TU/e Research Portal (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- remote photoplethysmography, blood volume pulse, motion robustness, RGB color space, pulse rate detection, signal-to-noise ratio, non-contact vital sign monitoring, exercise monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review