A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain concerning how well a dipolar source can be localized under such conditions, especially when using few sensors. In this paper, we investigate the source localization capabilities using an array of scalar OPMs in the presence of a large background field while varying dipole strength, sensor count, and forward model accuracy. We also consider localization performance as the orientation angle of the background field changes. Our results are validated experimentally through accurate localization using a phantom virtual array mimicking a current dipole in a conducting sphere in a large background field. Our results are intended to give researchers a general sense of the capabilities and limitations of scalar OPMs for magnetoencephalography systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both technologies have also proven sufficiently sensitive for unshielded MEG and brain source localization using an array of scalar OPMs in the presence of a large background field (280–284).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [283]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Therefore, for a given biomagnetic signal, the measurement results of scalar OPMs are related to the orientation of participants with respect to the background field (52).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [52]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the limited memory BFGS method for large scale optimization
Liu, D. C., & Nocedal, J. (1989) · Mathematical Programming · doi:10.1007/bf01589116 · Cited by 8,560 · cited 3×
“L-BFGS iterates through the space of possible values for ( )p q, tofind a fitminimizing residual error.”
MethodInfluentialHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“A typical physiological current dipole generated by synchronous neural activity is 10 nAm (Hämäläinen et al 1993).”
BackgroundBasic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 2×
“Models and algorithms Following the generalMEGmethod for dipole localization in a conducting sphere (Sarvas 1987), the sources are modeled as current dipoles (Cohen andHosaka 1976) specified by their position, orientation, andmagnitude of directional current flow.”
MethodInfluentialA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“To rival the sensitivities of SQUIDS,OPMsmust operate in the spin-exchange relaxation-free (SERF) regime (Allred et al 2002, Kominis et al 2003).”
MethodMoving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992 · cited 2×
“Furthermore, tofit all users, the rigidDewars are sized tofit large human heads, severely limiting their usefulness on young children (Baillet 2017).”
BackgroundUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 2×
“Since the early 1990s, superconducting quantum interference devices (SQUIDs) have been stalwarts in the world of MEG [2].”
Background
Research works printed but not linked: 6
- [24] R. J. Ilmoniemi and J. Sarvas, Brain signals: Physics and mathematics of MEG and EEG . Mit Press, 2019. -
- [13] M. Limes, J. Foley, T. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V.-G. Lucivero, and M. Romalis, 'A sensitive all-optical portable scalar 87 rb atomic gradiometer operating in earth's field,' Bulletin of the American Physical Society , 2020. -
- [14] M. Limes, E. Foley, T. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V. Lucivero, and M. Romalis, 'Total-field atomic gradiometer for unshielded portable magnetoencephalography,' arXiv preprint arXiv:2001.03534 , 2020. - · arXiv
- [26] M. H¨ am¨ al¨ ainen, R. Hari, R. J. Ilmoniemi, J. Knuutila, and O. V. Lounasmaa, 'Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain,' Reviews of modern Physics , vol. 65, no. 2, p. 413, 1993. -
- [1] S. Supek and C. J. Aine, Magnetoencephalography . Springer, 2016. -
- [32] G. Uehara, Y. Adachi, I. Hashimoto, and M. Yumoto, 'A triangle-coil phantom as an evaluation standard for meg system,' The Journal of Japan Biomagnetism and Bioelectromagnetics Society , vol. 21, pp. 11-17, 2008. -
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“…as B tot ¼ ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi q Therefore, for a given biomagnetic signal, the measurement results of scalar OPMs are related to the orientation of participants with respect to the background field ( 52 ).”
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Applications of OPM-MEG for translational neuroscience: a perspective
Brickwedde, M., Anders, P., Kühn, A. A., Lofredi, R., Holtkamp, M., Kaindl, A. M., Grent-‘t-Jong, T., Krüger, P., Sander, T. H., & Uhlhaas, P. J. (2024) · Translational Psychiatry · doi:10.1038/s41398-024-03047-y · Cited by 72
“While sensor developments also explore the possibility of shielding-free applications [132], it is uncertain whether OPMs will provide reliable recordings of brain activity in the presence of large magnetic background fi elds [33, 133, 134].”
BackgroundMiniature Biplanar Coils for Alkali-Metal-Vapor Magnetometry
Tayler, M. C. D., Mouloudakis, K., Zetter, R., Hunter, D., Lucivero, V. G., Bodenstedt, S., Parkkonen, L. T., & Mitchell, M. W. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.014036 · Cited by 51
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
Optimizing NV magnetometry for magnetoneurography and magnetomyography applications
Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1034391 · Cited by 34
“Besides, efforts have been made to enhance the dynamic range of NVmagnetometers (Clancy et al., 2021; Zhang et al., 2022), and the dynamic range of NV magnetometers is much larger than the OPMs.”
BackgroundA 4He vector zero-field optically pumped magnetometer operated in the Earth-field
Bertrand, F., Jäger, T., Boness, A., Fourcault, W., Gal, G. L., Palacios-Laloy, A., Paulet, J., & Léger, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062791 · Cited by 26
“Thus MCG and MEG recordings out of shieldings have been performed with scalar magnetometers [23,24], but scalar data is poorer than vector data [25,26].”
Optimising the sensing volume of OPM sensors for MEG source reconstruction
Bezsudnova, Y., Koponen, L. M., Barontini, G., Jensen, O. B., & Kowalczyk, A. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119747 · Cited by 24
All-Optical Nonzero-Field Vector Magnetic Sensor for Magnetoencephalography
Petrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024001 · Cited by 15
“This expected vector sensitivity approaches that required of the three-component sensor for operation in MEG complexes; this is indirectly confirmed by the results of [39].”
ResultDong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 16
“10 of 17 Richard J Clancy et al. has discussed how well a dipolar source could theoretically be localized through fi eld gradient detection without shielding [55]. pumping beam and the probe beam were on the same axis, which was the only dead axis.”
BackgroundAnalysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer
Yan, Y., Lu, J., Zhou, B., Wang, K., Liu, Z., Li, X., Wang, W., & Liu, G. (2022) · Photonics · doi:10.3390/photonics9090654 · Cited by 15
Large-scale multipass two-chamber rf atomic magnetometer
Heilman, D. J., Sauer, K. L., Prescott, D. W., Motamedi, C. Z., Dural, N., Romalis, M. V., & Kornack, T. W. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054024 · Cited by 13
Intrinsic radio-frequency gradiometer
Cooper, R. J., Prescott, D. W., Sauer, K. L., Dural, N., & Romalis, M. V. (2022) · Physical Review A · doi:10.1103/physreva.106.053113 · Cited by 14
Wang, R., Yu-jie, M., Zhao, R., Ding, J., Li, L., Yang, Y., Wang, F., Cao, Z., Zhang, X., Lin, X., et al. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121403 · Cited by 12
Bedside Magnetocardiography with a Scalar Sensor Array
Iwata, G. Z., Nguyen, C. T., Tharratt, K., Ruf, M., Reinhardt, T., Crivelli-Decker, J. E., Liddy, M. S. Z., Rugar, A. E., Lu, F., Aschbacher, K., et al. (2024) · Sensors · doi:10.3390/s24165402 · Cited by 12
“[30], this enables a high CMRR without the need for strict tolerances on sensor orientation/alignment.”
BackgroundAkbar, A., Koźbiał, M., Elson, L., Meraki, A., Kołodyński, J., & Jensen, K. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054033 · Cited by 10
Helbling, S. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00410 · Cited by 9
Petrenko, M., & Vershovskii, A. (2022) · Sensors · doi:10.3390/s22249862 · Cited by 6
“The possibilities and prospects for the use of scalar non-zero-field optical magnetometers (the class to which the sensor presented in this work belongs) were studied in [20] and partially in [23].”
BackgroundIto, Y., Ueda, H., Oida, T., Moriya, T., Saito, A., & Suyama, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-77089-z · Cited by 6
“in unshielded environments 11,12 .”
Spatial and Frequency Specific Artifact Reduction in Optically Pumped Magnetometer Recordings
Xiang, J., Tong, H., Jiang, Y., & Barnes‐Davis, M. E. (2022) · Journal of Integrative Neuroscience · doi:10.31083/j.jin2105145 · Cited by 5
“OPM MEG instrumentation can be contained inside of small cylindrical shields [6, 7] or may potentially be employed without shielding [2].”
BackgroundTian, X., Bao, B., Wang, R., & Li, D. (2025) · Sensors · doi:10.3390/s25123690 · Cited by 3
“In addition, it is also much easier to miniaturize the sensor to construct a sensor array, which is very crucial in biomedical applications, such as magnetocardiography [12], magnetoencephalography [13], and biomarker detection of magnetic markers [14,15].”
Synergistic Voluntary Muscle Signal Characteristic Analysis and Comparison of OPM-MMG and sEMG
Yu, H., Gao, Y., Wu, H., & Ning, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3613905 · Cited by 2
“Furthermore, while the electric fields generated by current dipoles decay proportionally to the square of the distance, the magnetic fields produced by magnetic dipoles decay with the cube of the distance [16].”
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2026) · Sensors · doi:10.3390/s26041369 · Cited by 6
Shi, M., Zhang, W., Wang, L., Zhang, F., Hou, J., & Yang, C. (2024) · The European Physical Journal Applied Physics · doi:10.1051/epjap/2024230162 · Cited by 2
Optical Magnetometric Sensor for Magnetoencephalographic Complexes
Vershovskii, A. K., & Petrenko, M. V. (2023) · Technical Physics Letters · doi:10.1134/s1063785023900601 · Cited by 2
Frequency-Dependent Amplitude Correction to Free-Precession Scalar Magnetometers
Limes, M. E., Rathbun, L., Foley, E., Kornack, T., Hainsel, Z., & Braun, A. M. (2024) · IEEE Sensors Letters · doi:10.1109/lsens.2024.3517345 · Cited by 2
“Currently arrays of the pump and probe scalar magnetometers are being fabricated for use in source localization in MEG trials, where existing MEG algorithms need modified for use with scalar sensors [14].”
MethodMagnetoencephalography Without a Shielded RoomPreprint
Bezsudnova, Y., Alexander, N., Mellor, S., Mitryukovskiy, S. I., Romain, R., Palacios-Laloy, A., Barnes, G. R., Callaghan, M. F., & Tierney, T. M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.06.743270 · Cited by 3
“Although single channel systems can be of great use in brain computer interface 22 or cardiac imaging 23 applications, they cannot achieve the spatial localization and whole brain coverage 24–26 that are critical for both clinical applications and discovery research 1,4 .”
Petrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2021) · IEEE Magnetics Letters · doi:10.1109/lmag.2021.3132851 · Cited by 2
Vershovskii, A. K., & Petrenko, M. V. (2023) · Оптика и спектроскопия · doi:10.21883/eos.2023.01.55509.4439-22 · Cited by 1
Biomagnetic sensing: technologies and applications
Guo, H., Wu, T., Sun, C., Zhao, B., & Yang, X. (2024) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2024-1029 · Cited by 1
Vershovskii, A. K., & Петренко, М. В. (2023) · Оптика и спектроскопия · doi:10.21883/os.2023.01.54530.4439-22
Оптический магнитометрический датчик для магнитоэнцефалографического комплекса
Vershovskii, A. K., & Петренко, М. В. (2023) · Письма в журнал технической физики · doi:10.21883/pjtf.2023.06.54817.19378
Optical magnetometric sensor for magnetoencephalographic complexes
Vershovskii, A. K., & Petrenko, M. V. (2023) · Письма в журнал технической физики · doi:10.21883/tpl.2023.03.55693.19378
Vershovskii, A. K., & Petrenko, M. V. (2023) · Optics and Spectroscopy · doi:10.1134/s0030400x23040215 · Cited by 1
Oida, T., MORIYA, T., Saito, A., Hiroyuki, U. E. D. A., Ito, Y., & Suyama, M. (2024) · Japanese Journal of Magnetic Resonance in Medicine · doi:10.2463/jjmrm.2024-1834
Hou, X., Ye, C., Niu, Y., & Liu, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3626577
“If the open-type shielding device proposed by Zhang et al. [26], Nordenström et al. [27], and Clancy et al. [28] were adopted, it could further advance the degree of wireless integration; however, it would also face challenges such as increased signal interference.”
Lee, Y. S., & Woo, S. H. (2025) · Medical Lasers · doi:10.25289/ml.25.034
Probe-assisted depopulation pumping in low-pressure alkali-metal vapor cells for magnetometry
Limes, M. E., Smoot, J., Perez, J., Freeman, J., Amano-Dolan, C., Peters, D., & Lee, W. (2026) · Physical Review A · doi:10.1103/pbrt-m6q3
“Portable free-precession atomic magnetometers have sufficient performance unshielded in Earth’s field to detect MEG signals [10, 11], in addition to other various applications, due to their high dynamic range and linearity, resulting from frequency measurements ω of spins precessing due to a total…”
Unshielded magnetoencephalography source imaging: Simulation and analysis
Yang, X., Wang, Y., Wu, T., & Guo, H. M. (2026) · Physical Review Applied · doi:10.1103/knl3-99xh
Gal, G. L. (2022) · theses.fr (ABES) · doi:10.70675/087f6445zef80z4bbfz837ez1374c2977052
Kowalczyk, A., Bezsudnova, Y., Barontini, G., & Jensen, O. B. (2026) · University of Birmingham Research Portal (University of Birmingham) · doi:10.25500/edata.bham.00001639
Mapping the Earth's Magnetic Field Using Unmanned Aerial Vehicles
Švéda, M. (2026) · Brno University of Technology Digital Library (Brno University of Technology)
Compact all-optical atomic magnetometer for operation in unshielded environments
Lyu, Y., Xiao, W., Li, B. G., Luo, Y., Mao, X., Wu, T., & Guo, H. M. (2026) · Review of Scientific Instruments · doi:10.1063/5.0335753
Metadata
- Authors
- Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S.
- Affiliations
- University of Colorado
- Corresponding author
- Clancy, Richard J
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2021-09-03
- Volume
- 66
- Issue
- 17
- Pages
- 175030
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC9273178
- OpenAlex
- W3157077052
- Cited by
- 37
- References
- 28
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 10 · 2023: 10 · 2022: 7 · 2021: 2
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Physics in Medicine and Biology (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Defense Advanced Research Projects Agency (MINDSS under the N3 program Contract No. N6523619C8013)
- National Institutes of Health (R01EB027004)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Keywords
- optically pumped magnetometers, magnetoencephalography, source localization, dipole source localization, common-mode rejection, background magnetic field, sensor arrays, conducting sphere, current dipoles
- MeSH terms
- Brain, Magnetoencephalography, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.