A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain concerning how well a dipolar source can be localized under such conditions, especially when using few sensors. In this paper, we investigate the source localization capabilities using an array of scalar OPMs in the presence of a large background field while varying dipole strength, sensor count, and forward model accuracy. We also consider localization performance as the orientation angle of the background field changes. Our results are validated experimentally through accurate localization using a phantom virtual array mimicking a current dipole in a conducting sphere in a large background field. Our results are intended to give researchers a general sense of the capabilities and limitations of scalar OPMs for magnetoencephalography systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both technologies have also proven sufficiently sensitive for unshielded MEG and brain source localization using an array of scalar OPMs in the presence of a large background field (280–284).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [283]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Therefore, for a given biomagnetic signal, the measurement results of scalar OPMs are related to the orientation of participants with respect to the background field (52).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [52]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the limited memory BFGS method for large scale optimization
Liu, D. C., & Nocedal, J. (1989) · Mathematical Programming · doi:10.1007/bf01589116 · Cited by 8,560 · cited 3×
“L-BFGS iterates through the space of possible values for ( )p q, tofind a fitminimizing residual error.”
MethodInfluentialHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“A typical physiological current dipole generated by synchronous neural activity is 10 nAm (Hämäläinen et al 1993).”
BackgroundBasic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 2×
“Models and algorithms Following the generalMEGmethod for dipole localization in a conducting sphere (Sarvas 1987), the sources are modeled as current dipoles (Cohen andHosaka 1976) specified by their position, orientation, andmagnitude of directional current flow.”
MethodInfluentialA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“To rival the sensitivities of SQUIDS,OPMsmust operate in the spin-exchange relaxation-free (SERF) regime (Allred et al 2002, Kominis et al 2003).”
MethodMoving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992 · cited 2×
“Furthermore, tofit all users, the rigidDewars are sized tofit large human heads, severely limiting their usefulness on young children (Baillet 2017).”
BackgroundUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 2×
“Since the early 1990s, superconducting quantum interference devices (SQUIDs) have been stalwarts in the world of MEG [2].”
Background75th Anniversary: The historical development of the magnetic method in exploration
Nabighian, M. N., Grauch, V. J. S., Hansen, R. O., LaFehr, T. R., Li, Y., Peirce, J. W., Phillips, J. D., & Ruder, M. E. (2005) · Geophysics · doi:10.1190/1.2133784 · Cited by 713 · cited 1×
“Since scalarOPMs are less sensitive to their orientation, they are commonly used on moving or vibrating platforms for unexploded ordinance detection, geophysical surveying, and exploration (David et al 2004,Nabighian et al 2005,Du et al 2017).”
Kastler, A. (1950) · Journal de Physique et le Radium · doi:10.1051/jphysrad:01950001106025500 · Cited by 618 · cited 1×
“While theywere first developed in the 1950s (Kastler 1950) and used for biomagneticmeasurements since the 1970s (Livanov et al 1978), only recently have they reached noisefloors sufficient forMEGapplications and been demonstrated in small packaged sensors (Limes et al 2020a).”
BackgroundChip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481 · cited 1×
“An alternative to zero-fieldOPMs are total-field or scalarOPMs, which are being developed in microfabricated packages (Schwindt et al 2004) orwith high sensitivities (Sheng et al 2013).”
BackgroundSelf-citationMeasurement of Areas on a Sphere Using Fibonacci and Latitude–Longitude Lattices
González, Á. (2010) · Mathematical Geosciences · doi:10.1007/s11004-009-9257-x · Cited by 450
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364 · cited 1×
“An alternative to zero-fieldOPMs are total-field or scalarOPMs, which are being developed in microfabricated packages (Schwindt et al 2004) orwith high sensitivities (Sheng et al 2013).”
A better way to construct the sunflower head
Vogel, H. (1979) · Mathematical Biosciences · doi:10.1016/0025-5564(79)90080-4 · Cited by 360 · cited 2×
“Except for bias field orientation simulations, sensors were placed on the upper half of a hemisphere along a Fibonacci spiral [28, 29] which is a parametric curve giving nearly uniform coverage over a spherical surface.”
MethodOptical Detection of Magnetic Resonance in Alkali Metal Vapor
Bell, W. E., & Bloom, A. L. (1957) · Physical Review · doi:10.1103/physrev.107.1559 · Cited by 268 · cited 2×
“The pulsedOPMconcept is described in detail in Gerginov et al (2020); it is based on optically-driven spin precession (Bell and Bloom1957) using amplitudemodulated pump light.”
MethodPortable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257 · cited 4×
“For that reason, totalfieldmagnetometers realize higher common-mode rejection ratios than their vector counterparts (Limes et al 2020b).”
BackgroundInfluentialRecording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222
Part II magnetic field produced by a current dipole
Cohen, D., & Hosaka, H. (1976) · Journal of Electrocardiology · doi:10.1016/s0022-0736(76)80041-6 · Cited by 129
Scalar Magnetometry Below 100 fT/Hz1/2 in a Microfabricated Cell
Gerginov, V. P., Pomponio, M., & Knappe, S. A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3002193 · Cited by 59 · cited 2×
“In our experiments, we used a scalarOPM sensorwith a noisefloor of 70 fT/ Hz (Gerginov et al 2020) and measurement bandwidth of 100 Hz.”
MethodSelf-citationZhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48 · cited 2×
“Work has begun on detecting brain signals in unshielded environments (Limes et al 2020b, Zhang et al 2020).”
BackgroundMethodA rival to Stonehenge? Geophysical survey at Stanton Drew, England
David, A., Cole, M., Horsley, T., Linford, N., Linford, P., & Martin, L. (2004) · Antiquity · doi:10.1017/s0003598x00113006 · Cited by 41 · cited 2×
“Since scalar OPMs are less sensitive to their orientation, they are commonly used on moving or vibrating platforms for unexploded ordinance detection (UXO), geophysical surveying, and exploration [17, 18, 19].”
BackgroundDry phantom for magnetoencephalography —Configuration, calibration, and contribution
Oyama, D., Adachi, Y., Yumoto, M., Hashimoto, I., & Uehara, G. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.05.004 · Cited by 40 · cited 1×
“To validate ourmethod, we constructed a dry phantom tomimic a current dipole in a conducting sphere (Ilmoniemi et al 1985,Oyama et al 2015,Uehara et al 2008).”
MethodPerry, A. R., Bulatowicz, M. D., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · Optics Express · doi:10.1364/oe.408486 · Cited by 39 · cited 1×
“This allows for the detection of very small signals in the presence of large background fields,making themwell suited for use in unshielded environments (Perry et al 2020, Zhang et al 2020).”
MethodDetection of a Moving Magnetic Dipole Target Using Multiple Scalar Magnetometers
Du, C., Xia, M., Huang, S.-X., Xu, Z., Peng, X., & Guo, H. M. (2017) · IEEE Geoscience and Remote Sensing Letters · doi:10.1109/lgrs.2017.2701906 · Cited by 32 · cited 1×
“Since scalarOPMs are less sensitive to their orientation, they are commonly used on moving or vibrating platforms for unexploded ordinance detection, geophysical surveying, and exploration (David et al 2004,Nabighian et al 2005,Du et al 2017).”
[Recording of human magnetic fields].
Mn, L., Kozlov, A. N., Korinevskiĭ, A. V., Vp, M., & Sinel'nikova, S. E. (1978) · PubMed · Cited by 12
Research works printed but not linked: 6
- [24] R. J. Ilmoniemi and J. Sarvas, Brain signals: Physics and mathematics of MEG and EEG . Mit Press, 2019. -
- [13] M. Limes, J. Foley, T. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V.-G. Lucivero, and M. Romalis, 'A sensitive all-optical portable scalar 87 rb atomic gradiometer operating in earth's field,' Bulletin of the American Physical Society , 2020. -
- [14] M. Limes, E. Foley, T. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V. Lucivero, and M. Romalis, 'Total-field atomic gradiometer for unshielded portable magnetoencephalography,' arXiv preprint arXiv:2001.03534 , 2020. - · arXiv
- [26] M. H¨ am¨ al¨ ainen, R. Hari, R. J. Ilmoniemi, J. Knuutila, and O. V. Lounasmaa, 'Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain,' Reviews of modern Physics , vol. 65, no. 2, p. 413, 1993. -
- [1] S. Supek and C. J. Aine, Magnetoencephalography . Springer, 2016. -
- [32] G. Uehara, Y. Adachi, I. Hashimoto, and M. Yumoto, 'A triangle-coil phantom as an evaluation standard for meg system,' The Journal of Japan Biomagnetism and Bioelectromagnetics Society , vol. 21, pp. 11-17, 2008. -
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“…as B tot ¼ ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi q Therefore, for a given biomagnetic signal, the measurement results of scalar OPMs are related to the orientation of participants with respect to the background field ( 52 ).”
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Applications of OPM-MEG for translational neuroscience: a perspective
Brickwedde, M., Anders, P., Kühn, A. A., Lofredi, R., Holtkamp, M., Kaindl, A. M., Grent-‘t-Jong, T., Krüger, P., Sander, T. H., & Uhlhaas, P. J. (2024) · Translational Psychiatry · doi:10.1038/s41398-024-03047-y · Cited by 72
“While sensor developments also explore the possibility of shielding-free applications [132], it is uncertain whether OPMs will provide reliable recordings of brain activity in the presence of large magnetic background fi elds [33, 133, 134].”
BackgroundMiniature Biplanar Coils for Alkali-Metal-Vapor Magnetometry
Tayler, M. C. D., Mouloudakis, K., Zetter, R., Hunter, D., Lucivero, V. G., Bodenstedt, S., Parkkonen, L. T., & Mitchell, M. W. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.014036 · Cited by 51
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
Metadata
- Authors
- Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S.
- Affiliations
- University of Colorado
- Corresponding author
- Clancy, Richard J
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2021-09-03
- Volume
- 66
- Issue
- 17
- Pages
- 175030
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC9273178
- OpenAlex
- W3157077052
- Cited by
- 37
- References
- 28
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 10 · 2023: 10 · 2022: 7 · 2021: 2
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Physics in Medicine and Biology (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Defense Advanced Research Projects Agency (MINDSS under the N3 program Contract No. N6523619C8013)
- National Institutes of Health (R01EB027004)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Keywords
- optically pumped magnetometers, magnetoencephalography, source localization, dipole source localization, common-mode rejection, background magnetic field, sensor arrays, conducting sphere, current dipoles
- MeSH terms
- Brain, Magnetoencephalography, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.