Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?
Open accessAbstract
Pulse rate variability (PRV) analysis appears as the first alternative to heart rate variability analysis for wearable devices; however, there is a constraint on computational load and energy consumption for the limited system resources available to the devices. Considering that adjustment of the sampling frequency is one of the strategies for reducing computational load and power consumption, this study aimed to investigate the influence of sampling frequency ( f s ) on PRV analysis and to find the minimum sampling frequency while maintaining reliability. We generated 5000, 2500, 1000, 500, 250, 100, 50, 25, 20, 15, 10, 5 Hz down-sampled photoplethysmograms from 10 kHz-sampled PPGs and derived time- and frequency-domain variables of the PRV. These included AVNN, SDNN, SDSD, RMSSD, NN50, pNN50, total power, VLF, LF, HF, LF/HF, nLF and nHF for each down-sampled signal. Derived variables were compared with heart rate variability of the 10 kHz-sampled electrocardiograms, and then statistically investigated using one-way ANOVA test and Bland–Altman analysis. As a result, significant differences ( P < 0.05) were found for SDNN, SDSD, RMSSD, NN50, pNN50, TP, HF, LF/HF, nLF and nHF, but not for AVNN, VLF and LF. Based on the post hoc tests, it was found that the NN50 and pNN50, SDSD and RMSSD, LF/HF and nHF, SDNN, TP and nLF analysis had significant differences at f s ⩽ 20 Hz, f s ⩽ 15 Hz, f s ⩽10 Hz; f s = 5 Hz, respectively. In other words, a significant difference was not seen for any variable if the f s was greater than 25 Hz. Consequently, our pilot study suggests that analysis of variability in the time and frequency domain from pulse rate obtained through PPG may be potentially as reliable as that derived from the analysis of the electrocardiogram, provided that f s ⩾25 Hz sampling frequency is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Rapid irregularly conducted AF may produce variable pulse pressures that challenge detection (Choi 2017).”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Choi 2017
Experimental — accuracy not yet measuredIn the citing paper
“Second, the PPG can be interpolated to increase performance [130], [131].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [130]
In the citing paper
“First, the PPG sampling rate should be sufficiently high (at least 25 Hz [130]).”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Contributions to Probability and Statistics: Essays in Honor of Harold Hotelling.
David, F. N., Olkin, I., Ghurye, S. G., Hoeffding, W., Madow, W. G., & Mann, H. B. (1961) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2984135 · Cited by 1,914
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Discrete Time Signal Processing
Chitode, J. S. (2011) · Cited by 798
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Lü, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 352
Towards Measuring Stress with Smartphones and Wearable Devices During Workday and Sleep
Muaremi, A., Arnrich, B., & Tröster, G. (2013) · BioNanoScience · doi:10.1007/s12668-013-0089-2 · Cited by 302
Lu, S. F., Zhao, H., Ju, K., Shin, K., Lee, M., Shelley, K. H., & Chon, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9103-y · Cited by 284
Flagged first, then by citations
Research works printed but not linked: 3
- Flatt A A, 2015, Int. J. Sport Physiol., 10, 994
- Gregoski M J, 2012, Int. J. Telemed. Appl., 2012
- Hayano J, 2005, Biomed. Eng., 4, 62
Cited by
Sorted by citations
Items 101–116 of 116
Bester, M., Nichting, T. J., Joshi, R., Aissati, L., Oei, S. G., Mischi, M., van Laar, J. O. E. H., & Vullings, R. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13082442 · Cited by 1
Reducing Pulse Rate Variability Computational Error from a 30 Hz Photoplethysmography Recording
Panganiban, F. C., & de Leon, F. A. (2019) · International Symposium on Multimedia and Communication Technology (ISMAC) · doi:10.1109/ismac.2019.8836186
Recommendation for Measuring Digital Volume Pulse in Mobile Application: For Healthy Normal Subject
Seok, H. S., & Shin, H. (2021) · IEEE Access · doi:10.1109/access.2021.3077639
Self-citationRecommendation in Measuring Digital Volume Pulse for Mobile Application (Preprint)Preprint
Seok, H. S., & Shin, H. (2020) · doi:10.2196/preprints.24159
Self-citationPramulen, A. S., Cyberputri, D., Hasim, J. A. N., Fananda, I. Y., Wulandari, I., & Damastuti, F. A. (2024) · Transmisi: Jurnal Ilmiah Teknik Elektro · doi:10.14710/transmisi.26.2.77-85
Agarwal, S., & Sinha, R. K. (2025) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237225500036
Maternal Heart Rate Variability and Preterm Birth: A Systematic Review (Preprint)Preprint
Sharifi-Heris, Z., Rasouli, M., & Child, R. (2026) · doi:10.2196/preprints.93689
Han, X., Li, E. X., Volodarskiy, A., Slotwiner, D. J., & Zhao, Y. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae66c7
Hybrid deep learning-based blood glucose level monitoring using PPG signals
Soliman, A. Y., Nor, A. M., Omer, O. A., & Mubarak, A. S. (2026) · Signal Image and Video Processing · doi:10.1007/s11760-026-05368-5
Dynamic accuracy of lung simulation hardware: A comparative evaluation
Ferencz, M., Drath, R., & Dömer, B. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113366
Togo, E. (2026) · Biomedical Engineering and Computational Biology · doi:10.1177/11795972261452228
Wolling, F., Filipp, A., & Michahelles, F. (2026) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3830727.3834825
Estimating heart rate variability using facial video photoplethysmography: a pilot validation study
Pstras, L., Okupnik, T., Ponikowska, B., & Paleczny, B. (2026) · Scientific Reports · doi:10.1038/s41598-026-70292-0
Metadata
- Authors
- Choi, A., & Shin, H.
- Affiliations
- Gachon University (KR)
- Chonnam National University (KR)
- Corresponding author
- Choi, A
- Shin, H
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2017-02-23
- Volume
- 38
- Issue
- 3
- Pages
- 586-600
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2586184806
- Cited by
- 116
- References
- 25
- Citations by year
- 2026: 8 · 2025: 5 · 2024: 8 · 2023: 12 · 2022: 23 · 2021: 24 · 2020: 14 · 2019: 11 · 2018: 6 · 2017: 5
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Physiological Measurement (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Ministry of Science, ICT & Future Planning (NRF-2015R1C1A1A02036535)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- photoplethysmography, pulse rate variability, sampling frequency, downsampling, wearable devices, heart rate variability, signal reliability, power consumption, computational load, time and frequency domain analysis, electrocardiogram comparison
- MeSH terms
- Female, Heart Rate, Humans, Male, Pilot Projects, Signal Processing, Computer-Assisted, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review