Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpose of this study was to evaluate whether a wrist-worn photoplethysmography (PPG) device can be used to monitor beat-to-beat HR accurately during post-operative treatment in patients suffering from AF and whether wrist-PPG can be used to distinguish AF from sinus rhythm (SR). APPROACH: Twenty-nine patients (14 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine post-operative treatment. The monitoring included standard ECG, finger PPG monitoring and a wrist-worn PPG monitor with green and infrared light sources. The HR from PPG sensors was compared against ECG-derived HR. MAIN RESULTS: The wrist PPG technology had very good HR and beat detection accuracy when using green light. For the SR group, the mean absolute error (MAE) for HR was 1.50 bpm, and for the inter-beat intervals (IBI), the MAE was 7.64 ms. For the AF group, the MAE for HR was 4.28 bpm and for IBI, the MAE was 14.67 ms. Accuracy for the infrared (IR) channel was worse. Finger PPG provided similar accuracy for HR and better accuracy for the IBI. AF detection sensitivity using green light was 99.0% and the specificity was 93.0%. Performance can be improved by discarding unreliable IBI periods. SIGNIFICANCE: Results suggest that wrist PPG measurement allows accurate HR and beat-to-beat HR monitoring also in AF patients, and could be used for differentiating between SR and AF with very good sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339
Vermond, R. A., Geelhoed, B., Verweij, N., Tieleman, R. G., Van der Harst, P., Hillege, H. L., Van Gilst, W. H., Van Gelder, I. C., & Rienstra, M. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.06.1314 · Cited by 297
El-Amrawy, F., & Nounou, M. I. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.315 · Cited by 287
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
The advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209
Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609852 · Cited by 202
PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156
Cited by
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Kinnunen, H., Rantanen, A., Kenttä, T., & Koskimäki, H. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab840a · Cited by 184
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88
Non-invasive human vital signs monitoring based on twin-core optical fiber sensors
Tan, F., Chen, S., Lyu, W., Liu, Z., Yu, C., Lu, C., & Tam, H.-Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005940 · Cited by 62
Metadata
- Authors
- Harju, J., Tarniceriu, A., Parak, J., Vehkaoja, A., Yli-Hankala, A., & Korhonen, I.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2018-06-27
- Volume
- 39
- Issue
- 6
- Pages
- 065007
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2807343060
- Cited by
- 55
- References
- 12
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation. https://app.cochat.ai/papers/10.1088/1361-6579/aac9a9
- The paper
- Harju, J., Tarniceriu, A., Parak, J., Vehkaoja, A., Yli-Hankala, A., & Korhonen, I. (2018). Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation. Physiological Measurement. https://doi.org/10.1088/1361-6579/aac9a9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.