CoChat

Estimating blood pressure trends and the nocturnal dip from photoplethysmography

Open access
Radha, Mustafa, de Groot, Koen, Rajani, Nikita, Wong, Cybele C P, Kobold, Nadja, Vos, Valentina, Fonseca, Pedro, Mastellos, Nikolaos, Wark, Petra A, Velthoven, Nathalie, Haakma, Reinder, Aarts, Ronald M · 2019 · Physiological Measurement
Cited by 80

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Objective . Evaluate a method for the estimation of the nocturnal systolic blood pressure (SBP) dip from 24 h blood pressure trends using a wrist-worn photoplethysmography (PPG) sensor and a deep neural network in free-living individuals, comparing the deep neural network to traditional machine learning and non-machine learning baselines. Approach . A wrist-worn PPG sensor was worn by 106 healthy individuals for 226 d during which 5111 reference values for blood pressure (BP) were obtained with a 24 h ambulatory BP monitor and matched with the PPG sensor data. Features based on heart rate variability and pulse morphology were extracted from the PPG waveforms. Long- and short term memory (LSTM) networks, dense networks, random forests and linear regression models were trained and evaluated in their capability of tracking trends in BP, as well as the estimation of the SBP dip. Main results . Best performance for estimating the SBP dip were obtained with a deep LSTM neural network with a root mean squared error (RMSE) of 3.12 2.20 mmHg and a correlation of 0.69 . This dip was derived from trend estimates of BP which had an RMSE of 8.22 1.49 mmHg for systolic and 6.55 1.39 mmHg for diastolic BP (DBP). While other models had similar performance for the tracking of relative BP, they did not perform as well as the LSTM for the SBP dip. Significance : The work provides first evidence for the unobtrusive estimation of the nocturnal SBP dip, a highly prognostic clinical parameter. It is also the first to evaluate unobtrusive BP measurement in a large data set of unconstrained 24 h measurements in free-living individuals and provides evidence for the utility of LSTM models in this domain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/ab030e

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 80

Metadata

Authors
Radha, M., de Groot, K., Rajani, N., Wong, C. C. P., Kobold, N., Vos, V., Fonseca, P., Mastellos, N., Wark, P. A., Velthoven, N., Haakma, R., & Aarts, R. M.
Venue
Physiological Measurement
Published
2019-02-01
Volume
40
Issue
2
Pages
025006
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2903610377
Cited by
80
References
15
FWCI
3.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating blood pressure trends and the nocturnal dip from photoplethysmography. https://app.cochat.ai/papers/10.1088/1361-6579/ab030e
The paper
Radha, M., de Groot, K., Rajani, N., Wong, C. C. P., Kobold, N., Vos, V., Fonseca, P., Mastellos, N., Wark, P. A., Velthoven, N., Haakma, R., & Aarts, R. M. (2019). Estimating blood pressure trends and the nocturnal dip from photoplethysmography. Physiological Measurement. https://doi.org/10.1088/1361-6579/ab030e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.