Perspectives on electrical neural recording: a revisit to the fundamental concepts
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Objective . This paper aims to promote understanding on the fundamental concepts and mechanisms of extracellular electrical neural recording. Approach . First, the electrode-electrolyte interface is reviewed to clarify some of the frequent misunderstandings. Second, analytical solutions to the extracellular field potential and recorded signal are derived based on equivalent electrical circuit models, using a planar substrate microelectrode as a particular example. And third, factors affecting the recording quality are thoroughly assessed. Main results . Passive neural recording electrodes function as a pure capacitor. The extracellular field potential has two phases, with its subthreshold depolarization phase proportional to the first time derivative of the membrane depolarization and its action potential phase proportional to the negative first time derivative of the intracellular action potential. The recorded signal represents a portion of the extracellular field potential with both amplitude attenuation and phase distortion according to a voltage-divider circuit formed between the recording electrode and amplifier. A larger cell, a larger cell-substrate junctional membrane area, and a tighter membrane-substrate seal all help to improve the recording quality, while the effective electrode impedance should be minimized and the effective amplifier’s input impedance maximized. Significance . This paper develops in-depth insights to offer a clear image on the recording mechanism, nature of the signal, and interplays between key interface parameters. This work will make a foundational contribution to the field by providing such an in-depth understanding on this topic to clear the widespread ambiguities and confusions and inform rational neural electrode designs and proper interpretations of neural recordings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Biopotential amplifier designs use ac-coupled or dc-coupled structures for dc offset cancellation to avoid amplifier saturation due to the presence of electrode-tissue interface potentials [155], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
In the citing paper
“In addition, a large input impedance with respect to electrode impedance reduces signal attenuation [156], [158], [160].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
In the citing paper
“The μ V-level neural spike signal amplitudes and narrow bandwidths (200 Hz to 10 kHz) demand high-gain preamplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
The importance of phase in signals
Oppenheim, A. V., & Lim, J. S. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.12022 · Cited by 1,868 · cited 1×
“While the role of |Z[ | in affecting the recording SNR is generally well understood (see above and (5)), the frequent missing of the phase plot in literature reflects a lack of knowledge on the meaning of this piece of data [37].”
BackgroundMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991 · cited 2×
“unobservable by this class of electrodes [5, 27].”
BackgroundFoundations of Cellular Neurophysiology
Johnston, D., & Wu, S. M.-S. (1994) · Medical Entomology and Zoology · Cited by 910
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Robinson, J. T., Jorgolli, M., Shalek, A. K., Yoon, M.-H., Gertner, R. S., & Park, H. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.249 · Cited by 600 · cited 8×
“membrane time constant τ? = R?C?, which characterizes the rate the leaking current through R? discharges C?, is more than one order of magnitude larger than the durations of the subthreshold depolarization and the AP [2, 16].”
BackgroundInfluentialIntracellular recording of action potentials by nanopillar electroporation
Xie, C., Lin, Z., Hanson, L., Cui, Y., & Cui, B. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.8 · Cited by 593
On the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586 · cited 1×
“While intracellular recording, such as using glass micropipette or patch clamp electrodes, is valuable to neurophysiological studies with the acquisition of a signature waveform of the action potential (AP), extracellular recording, though complicated by the location, size, shape of the electrode, as well as neighbori…”
BackgroundCui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 1×
“As thickness of the Stern layer and the Debye length cannot be changed in physiologically relevant electrolyte, the only option is to increase Area by either roughening the smooth electrode surface [39] or coating it with rough and/or porous conductive materials including platinum black [35], conducting polymers [40,…”
BackgroundMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416 · cited 1×
“As thickness of the Stern layer and the Debye length cannot be changed in physiologically relevant electrolyte, the only option is to increase Area by either roughening the smooth electrode surface [39] or coating it with rough and/or porous conductive materials including platinum black [35], conducting polymers [40,…”
Background
Cited by
Recording Quality Is Systematically Related to Electrode Impedance
Lewis, C. M., Boehler, C., Liljemalm, R., Fries, P., Stieglitz, T., & Asplund, M. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303401 · Cited by 78
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
“(2) At neural recording relevant frequencies Rs may be considered resistive (Guo 2020).”
BackgroundInfluentialGuo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8fc5 · Cited by 12
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…and narrow bandwidths (200 Hz to 10 kHz) demand high-gain pre-amplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
Electrodeposited coatings for neural electrodes: A review
Li, L., & Jiang, C. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117492 · Cited by 11
Wang, X., Han, S., Yan, P., Lin, Y., Wang, C., Qian, L., Xing, P., Cao, Y., Song, X.-L., Wang, G., et al. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3460388 · Cited by 8
“Plat-inum electrodes are used for electrical recording [1], [5], and alternatives such as iridium oxide or titanium nitride can also be used as non-faradic depolarized electrodes [22], [32].”
Mathur, V., Talapatra, S., Kar, S., & Hennighausen, Z. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.1c00248 · Cited by 7
Multiphysics Finite-Element Modeling of the Neuron/Electrode Electrodiffusive Interaction
Leva, F., Verardo, C., Mele, L. J., Palestri, P., & Selmi, L. (2022) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors52175.2022.9967049 · Cited by 5
“They allow to gain insight on the transduction processes and derive more accurate and physics-based lumped-element circuit models [5]–[8].”
BackgroundAdditive manufacturing of multielectrode arrays for biotechnological applications
Edwards, A. V., Hann, C., Ivill, H., Leeson, H., Tymczyszyn, L., Cummings, D. M., Ashton, M., Harper, G. R., Spencer, D., Low, W. L., et al. (2021) · Materials Advances · doi:10.1039/d0ma00484g · Cited by 4
Leva, F., Palestri, P., & Selmi, L. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0013 · Cited by 7
“[71] C′ jm Clsh+Cain + Cm Clsh+Cain Rs Rjseal+Rjseal ( 1 + R2 R1 ) (4.”
BackgroundMethodResultInfluentialSolid-State Nanopores for Biomolecular Analysis and Detection
Stuber, A., Schlotter, T., Hengsteler, J., & Nakatsuka, N. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_240 · Cited by 5
The optimization of neuroprosthetic interfaces relying on biophysical and surrogate digital twins
Verardo, C., Fossati, V., Toni, L., Pierantoni, L., Losanno, E., Agnesi, F., & Romeni, S. (2026) · npj Biomedical Innovations. · doi:10.1038/s44385-026-00076-8 · Cited by 4
Weitin, T., Fabian, T., Glawion, A., Brottrager, J., & Pilz, Z. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1333965 · Cited by 2
“To increase the recording quality, we aimed for a high input and differential impedance (Guo, 2020).”
MethodExtracellular Recording of Propagating Action Potentials
Guo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_7 · Cited by 2
Self-citationHigh-Stability Polyimide-based Flexible Electrodes with IrO x to Interface the Mouse Vagus NervePreprint
Sun, T., Falcone, J., Crosfield, C., Lopez, M. F., Peragine, J., Modi, R., Sharma, R., Baker, B., Anderson, G., Savani, S., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.05.10.442867 · Cited by 5
“The deviation from the ideal pure capacitance was reported by the surface roughness, defects or even protein adsorption on the electrode (that is not a factor in this in vitro test) [36].”
BackgroundLeva, F., Verardo, C., Palestri, P., & Selmi, L. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3327617 · Cited by 1
“…with different levels of accuracy and complexity (in decreasing order): i) Hodgkin-Huxley (HH) [33] and HH-like models [29], [32], [34], [35], [36], [37]; ii) RC passive driven by voltage/current sources with HH-like waveforms [4], [5], [38]; iii) RC passive with AC input drive [5], [31], [39].”
BackgroundIntracortical Functional Neural Mapping Using an Integrated 3D Ultra-Density MEA
Guo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_11 · Cited by 1
Self-citationGuo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_10 · Cited by 1
Self-citationGuo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_3 · Cited by 1
Self-citationGuo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_5 · Cited by 1
Self-citationGuo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_6 · Cited by 1
Self-citationGuo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_12 · Cited by 1
Self-citationEquivalent Circuit Models of Neurons
Guo, L. (2021) · Springer eBooks · doi:10.1007/978-3-030-77677-0_2
Self-citationZou, Z., Shen, B., Xu, J., Tang, J., Wu, F., Gao, X., Xu, T., Li, S., Yang, Y., Wang, W., et al. (2021) · International Journal of Biomedical Science and Engineering · doi:10.11648/j.ijbse.20210904.14
“The ion concentration between the inner and outer parts of the cell is uneven, and due to the concentration difference, there is a difference in potential across the cell membrane [27, 28].”
Raj, L. P., Varsha, H. P., Farheen, S. M. R., Sangamesha, M. A., & Krishnaveni, S. (2026) · Journal of Electrostatics · doi:10.1016/j.elstat.2026.104309 · Cited by 1
Karami, N., Knafl, S., Wanzenboeck, H. D., & Prado‐Lòpez, S. (2026) · Frontiers in Electronics · doi:10.3389/felec.2026.1886715
“(Guo, 2020) • Directly proportional to the absolute transmembrane potential but attenuated.”
Guo, L. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/aeb442
“Conventional electrodes communicate with neurons via ionic-to-electronic current conversion across an electrical double layer at the interfacial boundary [9].”
Self-citationConducting polymers for implantable neural electrodes in brain–computer interfaces
Zhu, J., Liu, R., Jiang, H., Liu, X., Kong, Z., Wang, L., Xu, W., & Wang, Y. (2026) · Journal of Materials Chemistry B · doi:10.1039/d6tb01636g
Metadata
- Authors
- Guo, L.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Guo, Liang
- ORCID
- Guo, Liang
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2020-02-01
- Volume
- 17
- Issue
- 1
- Pages
- 013001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3003297322
- Semantic Scholar
- 77979e667a244e411b11cdd2140cd3be3814bfd7
- Cited by
- 28
- References
- 38
- Citations by year
- 2026: 5 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 12 · 2020: 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 24 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 24 d)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. National Science Foundation (1749701)
- Defense Advanced Research Projects Agency (D17AP00031)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- extracellular neural recording, electrode-electrolyte interface, extracellular field potentials, equivalent circuit model, electrode capacitance, action potential recording, phase distortion, voltage divider, recording quality, electrode impedance
- MeSH terms
- Animals, Electrodes, Implanted, Electrolytes, Humans, Microelectrodes, Neurons, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.