Perspectives on electrical neural recording: a revisit to the fundamental concepts
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Objective . This paper aims to promote understanding on the fundamental concepts and mechanisms of extracellular electrical neural recording. Approach . First, the electrode-electrolyte interface is reviewed to clarify some of the frequent misunderstandings. Second, analytical solutions to the extracellular field potential and recorded signal are derived based on equivalent electrical circuit models, using a planar substrate microelectrode as a particular example. And third, factors affecting the recording quality are thoroughly assessed. Main results . Passive neural recording electrodes function as a pure capacitor. The extracellular field potential has two phases, with its subthreshold depolarization phase proportional to the first time derivative of the membrane depolarization and its action potential phase proportional to the negative first time derivative of the intracellular action potential. The recorded signal represents a portion of the extracellular field potential with both amplitude attenuation and phase distortion according to a voltage-divider circuit formed between the recording electrode and amplifier. A larger cell, a larger cell-substrate junctional membrane area, and a tighter membrane-substrate seal all help to improve the recording quality, while the effective electrode impedance should be minimized and the effective amplifier’s input impedance maximized. Significance . This paper develops in-depth insights to offer a clear image on the recording mechanism, nature of the signal, and interplays between key interface parameters. This work will make a foundational contribution to the field by providing such an in-depth understanding on this topic to clear the widespread ambiguities and confusions and inform rational neural electrode designs and proper interpretations of neural recordings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Biopotential amplifier designs use ac-coupled or dc-coupled structures for dc offset cancellation to avoid amplifier saturation due to the presence of electrode-tissue interface potentials [155], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
In the citing paper
“In addition, a large input impedance with respect to electrode impedance reduces signal attenuation [156], [158], [160].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
In the citing paper
“The μ V-level neural spike signal amplitudes and narrow bandwidths (200 Hz to 10 kHz) demand high-gain preamplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [158]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
The importance of phase in signals
Oppenheim, A. V., & Lim, J. S. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.12022 · Cited by 1,868 · cited 1×
“While the role of |Z[ | in affecting the recording SNR is generally well understood (see above and (5)), the frequent missing of the phase plot in literature reflects a lack of knowledge on the meaning of this piece of data [37].”
BackgroundMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991 · cited 2×
“unobservable by this class of electrodes [5, 27].”
BackgroundFoundations of Cellular Neurophysiology
Johnston, D., & Wu, S. M.-S. (1994) · Medical Entomology and Zoology · Cited by 910
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Robinson, J. T., Jorgolli, M., Shalek, A. K., Yoon, M.-H., Gertner, R. S., & Park, H. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.249 · Cited by 600 · cited 8×
“membrane time constant τ? = R?C?, which characterizes the rate the leaking current through R? discharges C?, is more than one order of magnitude larger than the durations of the subthreshold depolarization and the AP [2, 16].”
BackgroundInfluentialIntracellular recording of action potentials by nanopillar electroporation
Xie, C., Lin, Z., Hanson, L., Cui, Y., & Cui, B. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.8 · Cited by 593
On the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586 · cited 1×
“While intracellular recording, such as using glass micropipette or patch clamp electrodes, is valuable to neurophysiological studies with the acquisition of a signature waveform of the action potential (AP), extracellular recording, though complicated by the location, size, shape of the electrode, as well as neighbori…”
BackgroundCui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 1×
“As thickness of the Stern layer and the Debye length cannot be changed in physiologically relevant electrolyte, the only option is to increase Area by either roughening the smooth electrode surface [39] or coating it with rough and/or porous conductive materials including platinum black [35], conducting polymers [40,…”
BackgroundMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416 · cited 1×
“As thickness of the Stern layer and the Debye length cannot be changed in physiologically relevant electrolyte, the only option is to increase Area by either roughening the smooth electrode surface [39] or coating it with rough and/or porous conductive materials including platinum black [35], conducting polymers [40,…”
BackgroundIn-cell recordings by extracellular microelectrodes
Hai, A., Shappir, J., & Spira, M. E. (2010) · Nature Methods · doi:10.1038/nmeth.1420 · Cited by 270 · cited 5×
“membrane time constant τ? = R?C?, which characterizes the rate the leaking current through R? discharges C?, is more than one order of magnitude larger than the durations of the subthreshold depolarization and the AP [2, 16].”
BackgroundMethodInfluentialLin, Z. C., Xie, C., Osakada, Y., Cui, Y., & Cui, B. (2014) · Nature Communications · doi:10.1038/ncomms4206 · Cited by 249 · cited 1×
“to increase the Ry)[E% and the junctional current for improved recording quality [2, 4, 16, 19, 22, 27, 31-33].”
BackgroundDipalo, M., Amin, H., Lovato, L., Moia, F., Caprettini, V., Messina, G. C., Tantussi, F., Berdondini, L., & De Angelis, F. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b01523 · Cited by 228 · cited 4×
“to increase the Ry)[E% and the junctional current for improved recording quality [2, 4, 16, 19, 22, 27, 31-33].”
BackgroundInfluentialElectrical Interfacing of Nerve Cells and Semiconductor Chips
Fromherz, P. (2002) · ChemPhysChem · doi:10.1002/1439-7641(20020315)3:3<276::aid-cphc276>3.0.co;2-a · Cited by 207 · cited 1×
“Modeling of the neuron-substrate electrode junctional interfaces has been reported by several groups over the past three decades [5, 22-26].”
BackgroundCell Adhesion as Wetting Transition?
Sackmann, E., & Bruinsma, R. F. (2002) · ChemPhysChem · doi:10.1002/1439-7641(20020315)3:3<262::aid-cphc262>3.0.co;2-u · Cited by 186
Review of signal distortion through metal microelectrode recording circuits and filters
Nelson, M. J., Pouget, P., Nilsen, E. A., Patten, C. D., & Schall, J. D. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.12.010 · Cited by 167
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160 · cited 1×
“As thickness of the Stern layer and the Debye length cannot be changed in physiologically relevant electrolyte, the only option is to increase Area by either roughening the smooth electrode surface [39] or coating it with rough and/or porous conductive materials including platinum black [35], conducting polymers [40,…”
BackgroundPilon, L., Wang, H., & d’Entremont, A. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0211505jes · Cited by 159
Hierlemann, A., Frey, U., Hafizovic, S., & Heer, F. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2066532 · Cited by 151
Hai, A., Dormann, A., Shappir, J., Yitzchaik, S., Bartic, C., Borghs, G., Langedijk, J. P. M., & Spira, M. E. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0087 · Cited by 142 · cited 19×
“However, this is not the case for large neurons from the invertebrate such as leech [31] and Aplysia [16, 19, 22].”
BackgroundInfluentialInterfacial interactions and their impact on redox-based resistive switching memories (ReRAMs)
Valov, I. (2017) · Semiconductor Science and Technology · doi:10.1088/1361-6641/aa78cd · Cited by 130 · cited 1×
“The Bockris/Devanathan/Müller (BDM) model describes this EDL as a cascade of three regions (Figure 1) [6, 8-12]: (1) an inner Helmholtz plane (IHP) formed by a layer of adsorbed water molecules with highly oriented dipole moments on the solid’s surface, (2) an intermediate outer Helmholtz plane (OHP) formed by solvate…”
BackgroundStretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128 · cited 2×
“H[(jω]) is conventionally presented as the magnitude and phase plots in logarithmic scales (see Figure 6 for an example [36]).”
BackgroundSelf-citationDesai, S. A. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00005 · Cited by 126 · cited 2×
“decreasing the electrode’s conventional impedance Z[ via increasing the C$%, and increasing the amplifier’s input impedance ZE>] [7, 34, 35].”
BackgroundHai, A., Shappir, J., & Spira, M. E. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00265.2010 · Cited by 123
Kampouris, D. K., Ji, X., Randviir, E. P., & Banks, C. E. (2015) · RSC Advances · doi:10.1039/c4ra17132b · Cited by 107
Hai, A., & Spira, M. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40091j · Cited by 97
Modeling the neuron-microtransducer junction: from extracellular to patch recording
Grattarola, M., & Martinoia, S. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204769 · Cited by 95 · cited 1×
“Modeling of the neuron-substrate electrode junctional interfaces has been reported by several groups over the past three decades [5, 22-26].”
BackgroundSmaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach
Castagnola, E., Ansaldo, A., Maggiolini, E., Ius, T., Skrap, M., Ricci, D., & Fadiga, L. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00008 · Cited by 78 · cited 2×
“Example magnitude (a) and phase (b) plots for the electrode impedance of a recording neural electrode array [34].”
BackgroundMicrochannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · cited 2×
“This perspective is supported by, for example, the finding that the lumen of a microchannel can effectively boost the amplitude of extracellularly recorded APs [20, 21], because of the substantial increase of R) in the microchannel.”
BackgroundNeuroprosthetics: Theory and Practice
Horch, K. W., & Dhillon, G. S. (2004) · Series on Bioengineering and Biomedical Engineering · doi:10.1142/4987 · Cited by 70
Massobrio, P., Massobrio, G., & Martinoia, S. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00282 · Cited by 60 · cited 2×
“3 ionic charge distributions in the IHP, OHP, and diffuse layer, respectively [6].”
BackgroundCohen, A., Shappir, J., Yitzchaik, S., & Spira, M. E. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.08.027 · Cited by 55
Analytical Solution to the Impedance of Electrode/Electrolyte Interface in Lithium-Ion Batteries
Huang, J., Li, Z. Y., Ge, H., & Zhang, J. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0081513jes · Cited by 53
Bistability of Membrane Conductance in Cell Adhesion Observed in a Neuron Transistor
Jenkner, M., & Fromherz, P. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.4705 · Cited by 52 · cited 2×
“to increase the Ry)[E% and the junctional current for improved recording quality [2, 4, 16, 19, 22, 27, 31-33].”
BackgroundMicrochannel Electrodes for Recording and Stimulation:In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · cited 2×
“This perspective is supported by, for example, the finding that the lumen of a microchannel can effectively boost the amplitude of extracellularly recorded APs [20, 21], because of the substantial increase of R) in the microchannel.”
BackgroundChaparro, C. V., Herrera, L. V., Meléndez, Á. M., & Miranda, D. A. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/687/1/012101 · Cited by 23 · cited 1×
“09 Ω∙m at room temperature [13], which give R) a value of around 1 kΩ for an electrode immersed in the center of a 10 cm diameter Petri dish.”
BackgroundOn neural recording using nanoprotrusion electrodes
Guo, L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab51de · Cited by 16 · cited 2×
“This IRy?(jω) is minimally affected by presence of the membrane-substrate junctional seal (modelled electrically by Ry)[E%) [17], so that the entire cell membrane can be considered to have a uniform”
BackgroundSelf-citationFrequency-domain analysis of intrinsic neuronal properties using high-resistant electrodes
Rössert, C. (2009) · Frontiers in Neuroscience · doi:10.3389/neuro.17.002.2009 · Cited by 10 · cited 1×
“Anyway, deconvolution should always be performed to recover VY(jω) from V>](jω) [2, 28, 29] based on (17), which is the negative first time derivative”
BackgroundA calibration-free electrode compensation method
Rossant, C., Fontaine, B., Magnusson, A. K., & Brette, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.01122.2011 · Cited by 4 · cited 2×
“Anyway, deconvolution should always be performed to recover VY(jω) from V>](jω) [2, 28, 29] based on (17), which is the negative first time derivative”
Background
Cited by
Recording Quality Is Systematically Related to Electrode Impedance
Lewis, C. M., Boehler, C., Liljemalm, R., Fries, P., Stieglitz, T., & Asplund, M. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303401 · Cited by 78
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
“(2) At neural recording relevant frequencies Rs may be considered resistive (Guo 2020).”
BackgroundInfluentialGuo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8fc5 · Cited by 12
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…and narrow bandwidths (200 Hz to 10 kHz) demand high-gain pre-amplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
Electrodeposited coatings for neural electrodes: A review
Li, L., & Jiang, C. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117492 · Cited by 11
Metadata
- Authors
- Guo, L.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Guo, Liang
- ORCID
- Guo, Liang
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2020-02-01
- Volume
- 17
- Issue
- 1
- Pages
- 013001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3003297322
- Semantic Scholar
- 77979e667a244e411b11cdd2140cd3be3814bfd7
- Cited by
- 28
- References
- 38
- Citations by year
- 2026: 5 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 12 · 2020: 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor, 24 d)
- iopscience.iop.org/info/page/text-and-data-mining (tdm, 24 d)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. National Science Foundation (1749701)
- Defense Advanced Research Projects Agency (D17AP00031)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- extracellular neural recording, electrode-electrolyte interface, extracellular field potentials, equivalent circuit model, electrode capacitance, action potential recording, phase distortion, voltage divider, recording quality, electrode impedance
- MeSH terms
- Animals, Electrodes, Implanted, Electrolytes, Humans, Microelectrodes, Neurons, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.