Abstract
OBJECTIVE: Technologically advanced assistive devices are nowadays available to restore grasping, but effective and effortless control integrating both feed-forward (commands) and feedback (sensory information) is still missing. The goal of this work was to develop a user friendly interface for the semi-automatic and closed-loop control of grasping and to test its feasibility. APPROACH: We developed a controller based on stereovision to automatically select grasp type and size and augmented reality (AR) to provide artificial proprioceptive feedback. The system was experimentally tested in healthy subjects using a dexterous hand prosthesis to grasp a set of daily objects. The subjects wore AR glasses with an integrated stereo-camera pair, and triggered the system via a simple myoelectric interface. MAIN RESULTS: The results demonstrated that the subjects got easily acquainted with the semi-autonomous control. The stereovision grasp decoder successfully estimated the grasp type and size in realistic, cluttered environments. When allowed (forced) to correct the automatic system decisions, the subjects successfully utilized the AR feedback and achieved close to ideal system performance. SIGNIFICANCE: The new method implements a high level, low effort control of complex functions in addition to the low level closed-loop control. The latter is achieved by providing rich visual feedback, which is integrated into the real life environment. The proposed system is an effective interface applicable with small alterations for many advanced prosthetic and orthotic/therapeutic rehabilitation devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Self-citationOnline Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
Self-citationClosed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 1×
“In some recent works, vibration motors [27], custom-made devices [28], electrical and hybrid stimulation [29] and also invasive approaches [30] have been tested.”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · cited 1×
“Also, implantable interfaces such as intra-fascicular neural electrodes [20] and implantable myoelectric sensors [21] have been tested for the same purpose.”
BackgroundSelf-citation
Cited by
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Computer vision has been combined with sEMG-based detection of movement intention to predetermine the type and size of the required grasp in relation to the object (Doˇsen et al., 2010; Markovic et al., 2014).”
MethodA Systematic Review of 10 Years of Augmented Reality Usability Studies: 2005 to 2014
Dey, A., Billinghurst, M., Lindeman, R. W., & Swan, J. E. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00037 · Cited by 434
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Will not include studies where the hand creates its own feedback loop without involving the user (such as camera to automatically recognise appropriate grip [36], or automatically adjusting grip when slip occurs [37], [38]).”
BackgroundShi, C., Yang, D., Zhao, J., & Liu, H. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3007625 · Cited by 87
“Although the RGB-Dataset [29] contains the depth data, it does not take the variations into account, such as the size and shape of the objects, which are important attributes for the determination of grasp pattern [12], [30].”
Background
Metadata
- Authors
- Markovic, M., Dosen, S., Cipriani, C., Popovic, D., & Farina, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-06-03
- Volume
- 11
- Issue
- 4
- Pages
- 046001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2010426277
- Cited by
- 136
- References
- 10
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stereovision and augmented reality for closed-loop control of grasping in hand prostheses. https://app.cochat.ai/papers/10.1088/1741-2560/11/4/046001
- The paper
- Markovic, M., Dosen, S., Cipriani, C., Popovic, D., & Farina, D. (2014). Stereovision and augmented reality for closed-loop control of grasping in hand prostheses. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/4/046001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.