A cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Present day cortical brain-machine interfaces (BMIs) have made impressive advances using decoded brain signals to control extracorporeal devices. Although BMIs are used in a closed-loop fashion, sensory feedback typically is visual only. However medical case studies have shown that the loss of somesthesis in a limb greatly reduces the agility of the limb even when visual feedback is available. APPROACH: To overcome this limitation, this study tested a closed-loop BMI that utilizes intracortical microstimulation to provide 'tactile' sensation to a non-human primate. MAIN RESULT: Using stimulation electrodes in Brodmann area 1 of somatosensory cortex (BA1) and recording electrodes in the anterior intraparietal area, the parietal reach region and dorsal area 5 (area 5d), it was found that this form of feedback can be used in BMI tasks. SIGNIFICANCE: Providing somatosensory feedback has the poyential to greatly improve the performance of cognitive neuroprostheses especially for fine control and object manipulation. Adding stimulation to a BMI system could therefore improve the quality of life for severely paralyzed patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
EPILEPSY AND THE FUNCTIONAL ANATOMY OF THE HUMAN BRAIN
Penfield, W., & Jasper, H. (1954) · Southern Medical Journal · doi:10.1097/00007611-195407000-00024 · Cited by 4,092
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Research works printed but not linked: 41
- Aaron R K, 2006, J. Am. Acad. Orthopaedic Surg., 14, S198, 10.5435/00124635-200600001-00043 · doi:10.5435/00124635-200600001-00043
- 10.1152/jn.00102.2007 · DOI
- 10.1016/0014-4886(86)90132-9 · DOI · Paper page
- Buchwald J S, 1970, J. Neurophysiol., 33, 148, 10.1152/jn.1970.33.1.148 · DOI
- Chen K H, 2014, J. Neural Eng., 11
- 10.1152/jn.00503.2010 · DOI · Paper page
- 10.1109/TNSRE.2005.856072 · DOI · Paper page
- 10.1523/JNEUROSCI.3516-07.2007 · DOI · Paper page
- 10.1523/JNEUROSCI.5297-06.2007 · DOI · Paper page
- 10.1038/nn.3265 · DOI · Paper page
- Hathaway S R, 1989, MMPI-2: Minnesota Multiphasic Personality Inventory-2: Manual for Administration and Scoring
- 10.1073/pnas.1215092109 · DOI · Paper page
- 10.1073/pnas.1215092109 · DOI · Paper page
- 10.1109/memsys.2008.4443637 · DOI · Paper page
- 10.1523/JNEUROSCI.2081-09.2009 · DOI · Paper page
- 10.1152/jn.00063.2011 · DOI
- 10.1109/cne.2007.369715 · DOI · Paper page
- Kim S P, 2008, J. Neural Eng., 5, 455, 10.1088/1741-2560/5/4/010 · DOI · Paper page
- 10.1109/TNSRE.2011.2107750 · DOI · Paper page
- 10.1073/pnas.0706525104 · DOI · Paper page
- 10.1590/S1807-59322011001300004 · DOI · Paper page
- 10.1016/0165-0270(80)90061-8 · DOI · Paper page
- Libet B, 1982, Human Neurobiol., 1, 235
- McCreery D B, 2010, J. Neural Eng., 7, 10.1088/1741-2560/7/3/036005 · DOI · Paper page
- 10.3389/neuro.07.020.2009 · DOI · Paper page
- 10.1109/TNSRE.2011.2166807 · DOI · Paper page
- 10.3171/jns.1995.82.4.0641 · DOI · Paper page
- 10.1016/B978-0-444-53815-4.00010-8 · DOI · Paper page
- Penfield W, 1950, The Cerebral Cortex of Man; a Clinical Study of Localization of Function
- 10.1007/BF00227792 · DOI
- Rizzuto D, 2006, Neurosci. conf.
- 10.1038/32891 · DOI · Paper page
- 10.1016/S0896-6273(00)81156-3 · DOI · Paper page
- 10.1038/416141a · DOI · Paper page
- 10.1523/JNEUROSCI.1321-07.2007 · DOI · Paper page
- 10.1126/science.1070291 · DOI · Paper page
- 10.1523/JNEUROSCI.4415-07.2008 · DOI · Paper page
- 10.3389/fncir.2012.00087 · DOI
- 10.1038/35042582 · DOI · Paper page
- Wu W, 2003, Adv. Neural Inf. Process. Syst., 15, 133
- 10.1162/089976606774841585 · DOI · Paper page
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Brain–machine interfaces from motor to mood
Shanechi, M. M. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0488-y · Cited by 263
Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation
Armenta Salas, M., Bashford, L., Kellis, S., Jafari, M., Jo, H., Kramer, D., Shanfield, K., Pejsa, K., Lee, B., Liu, C. Y., et al. (2018) · eLife · doi:10.7554/elife.32904 · Cited by 263
Self-citation
Metadata
- Authors
- Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-09-22
- Volume
- 11
- Issue
- 5
- Pages
- 056024
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2164705865
- Cited by
- 110
- References
- 21
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Funders
- the Defense Advanced Research Projects Agency
- the National Institutes of Health
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback. https://app.cochat.ai/papers/10.1088/1741-2560/11/5/056024
- The paper
- Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A. (2014). A cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/5/056024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.