Integrated parylene-cabled silicon probes for neural prosthetics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Recent advances in the field of neural prosthetics have demonstrated the thought control of a computer cursor. This capability relies primarily on electrode array surgically implanted into the brain as an acquisition source of neural activity. Various technologies have been developed for signal extraction; however most suffer from either fragile electrode shanks and bulky cables or inefficient use of surgical site areas. Here we present a design and initial testing results from high electrode density, silicon based arrays system with an integrated parylene cable. The greatly reduced flexible rigidity of the parylene cable is believed to relief possible mechanical damages due to relative motion between a brain and its skull.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Cited by
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Wang, R., Huang, X., Liu, G., Wang, W., Dong, F., & Li, Z. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039773 · Cited by 63
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
A cable-tie-type parylene cuff electrode for peripheral nerve interfaces
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765560 · Cited by 10
“The similar packaging approach has been previously presented in Huang’s work [10].”
Method
Metadata
- Authors
- Huang, R., Pang, C., Tai, Y. C., Emken, J., Ustun, C., Andersen, R., & Burdick, J.
- Venue
- 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems
- Publisher
- IEEE
- Published
- 2008-01
- Pages
- 240-243
- ISSN
- 1084-6999 (ISSN-L)
- OpenAlex
- W2146767383
- Cited by
- 23
- References
- 1
- FWCI
- 8.50
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated parylene-cabled silicon probes for neural prosthetics. https://app.cochat.ai/papers/10.1109/memsys.2008.4443637
- The paper
- Huang, R., Pang, C., Tai, Y. C., Emken, J., Ustun, C., Andersen, R., & Burdick, J. (2008). Integrated parylene-cabled silicon probes for neural prosthetics. 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems. https://doi.org/10.1109/memsys.2008.4443637
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.