A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non-physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed-loop brain-machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. APPROACH: We extend the usage of a robust adaptive noise cancelling (ANC) scheme ([Formula: see text] filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. MAIN RESULTS: Our results show over 95-99.9% correlation between the raw and processed signals at non-ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample-adaptive real-time framework. Decoding performance is also compared with multi-day experimental data from 2 subjects, totaling 19 sessions, with and without [Formula: see text] filtering of the raw data. SIGNIFICANCE: The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed-loop BMI applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Advanced Digital Signal Processing and Noise Reduction
Vaseghi, S. V. (2008) · Wiley eBooks · doi:10.1002/9780470740156 · Cited by 1,164
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005 · cited 1×
“These are relatively low impedance changes, and according to [19, 20], are not expected to have major amplitude changes especially under cool and dry experimental conditions.”
BackgroundRemoval of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638 · cited 1×
“In the case of ocular artifacts, a study reported that more than half ( 53.7% ) of the BMI studies considered in their survey do not mention whether or not they handle EOG artifacts, and 10.0% do not remove EOG artifacts, whereas 10.4% manually reject them [ 3 ] .”
BackgroundInfluentialThe effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447 · cited 1×
“These are relatively low impedance changes, and according to [19, 20], are not expected to have major amplitude changes especially under cool and dry experimental conditions.”
BackgroundExtended ICA Removes Artifacts from Electroencephalographic Recordings
Jung, T., Humphries, C., Lee, T.-W., Makeig, S., McKeown, M. J., Iragui, V. J., & B, T. J. S. A. (1997) · Cited by 425
Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG
Mullen, T., Kothe, C., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Cauwenberghs, G., & Jung, T.-P. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609968 · Cited by 390 · cited 2×
“This has been shown in fi gures 6 and 7.”
BackgroundMethodRemoval of ocular artifacts from electro-encephalogram by adaptive filtering
He, P., Wilson, G., & Russell, C. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344717 · Cited by 364
Sweeney, K. T., McLoone, S. F., & Ward, T. E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 300
Cited by
Deep learning for electroencephalogram (EEG) classification tasks: a review
Craik, A., He, Y., & Contreras-Vidal, J. L. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0ab5 · Cited by 1,758
Self-citationChang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Calabrò, R. S., Naro, A., Russo, M., Leo, A., De Luca, R., Balletta, T., Buda, A., La Rosa, G., Bramanti, A., & Bramanti, P. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0268-4 · Cited by 249
“EEG end EOG were sampled at 500 Hz, high pass filtered at 1 Hz using a zerophase FIR filter (order 7500) to minimize drifts, low pass filtered at 200 Hz (zerophase FIR filter order 36), and referenced to Cz [49].”
MethodInfluentialWireless EEG: A survey of systems and studies
Niso, G., Romero, E., Moreau, J. T., Araujo, A., & Krol, L. R. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2022.119774 · Cited by 244
Brain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Self-citationIdentification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“They showed that adaptive filtering based artifact removal can enhance the decoding accuracy of brain-machine interfaces [77].”
BackgroundReview of challenges associated with the EEG artifact removal methods
Mumtaz, W., Rasheed, S., & Irfan, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102741 · Cited by 182
Luu, T. P., Nakagome, S., He, Y., & Contreras-Vidal, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-09187-0 · Cited by 101
Self-citationQuiles, V., Ferrero, L., Iáñez, E., Ortiz, M., Cano, J. M., & Azorín, J. M. (2022) · Applied Sciences · doi:10.3390/app12010415 · Cited by 10
Metadata
- Authors
- Kilicarslan, A., Grossman, R. G., & Contreras-Vidal, J. L.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-10
- Volume
- 13
- Issue
- 2
- Pages
- 026013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2485686941
- Cited by
- 184
- References
- 18
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.