Individual finger control of a modular prosthetic limb using high-density electrocorticography in a human subject
Open accessThe DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
Abstract
Objective. We used native sensorimotor representations of fingers in a brain–machine interface (BMI) to achieve immediate online control of individual prosthetic fingers. Approach. Using high gamma responses recorded with a high-density electrocorticography (ECoG) array, we rapidly mapped the functional anatomy of cued finger movements. We used these cortical maps to select ECoG electrodes for a hierarchical linear discriminant analysis classification scheme to predict: (1) if any finger was moving, and, if so, (2) which digit was moving. To account for sensory feedback, we also mapped the spatiotemporal activation elicited by vibrotactile stimulation. Finally, we used this prediction framework to provide immediate online control over individual fingers of the Johns Hopkins University Applied Physics Laboratory modular prosthetic limb. Main results . The balanced classification accuracy for detection of movements during the online control session was 92% (chance: 50%). At the onset of movement, finger classification was 76% (chance: 20%), and 88% (chance: 25%) if the pinky and ring finger movements were coupled. Balanced accuracy of fully flexing the cued finger was 64%, and 77% had we combined pinky and ring commands. Offline decoding yielded a peak finger decoding accuracy of 96.5% (chance: 20%) when using an optimized selection of electrodes. Offline analysis demonstrated significant finger-specific activations throughout sensorimotor cortex. Activations either prior to movement onset or during sensory feedback led to discriminable finger control. Significance. Our results demonstrate the ability of ECoG-based BMIs to leverage the native functional anatomy of sensorimotor cortical populations to immediately control individual finger movements in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, the high spatial and temporal resolution of ECoG and LFPs can provide finer and more accurate control signals for prostheses as the neuronal areas can be recorded independently at a higher density.[333,334]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [333]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702 · cited 1×
“Trials were initiated by an experimenter on a presentation computer running psychtoolbox-3 [36] in MATLAB (MathWorks, Inc.”
MethodReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Porro, C. A., Francescato, M. P., Cettolo, V., Diamond, M. E., Baraldi, P., Zuiani, C., Bazzocchi, M., & di Prampero, P. E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-23-07688.1996 · Cited by 924
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Regularized linear discriminant analysis and its application in microarrays
Guo, Y., Hastie, T., & Tibshirani, R. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj035 · Cited by 597
Constraints on Somatotopic Organization in the Primary Motor Cortex
Schieber, M. H. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.5.2125 · Cited by 596 · cited 2×
“In spite of the evidence of limited finger somatotopy in motor cortex [22, 23, 25], both ECoG and fMRI studies have found a degree of separability in the peak population responses for different fingers in the precentral gyrus [26, 27].”
BackgroundEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Research works printed but not linked: 2
- [28].Johannes MS, Bigelow JD, Burck JM, Harshbarger SD, Kozlowski MV, Van Doren T. An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 2011;30(no. 3):207–216. [Google Scholar]
- [56].Muelling K, Venkatraman A, Valois J-S, Downey J, Weiss J, Javdani S, Hebert M, Schwartz AB, Collinger JL, Bagnell JA. Autonomy Infused Teleoperation with Application to BCI Manipulation. ArXiv Prepr. 2015 ArXiv150305451. [Google Scholar] Associated Data This section collects any data citations, data availability statements, or supplementary materials included in this article.
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Human augmentation: Past, present and future
Raisamo, R., Rakkolainen, I., Majaranta, P., Salminen, K., Rantala, J., & Farooq, A. (2019) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2019.05.008 · Cited by 236
Mood variations decoded from multi-site intracranial human brain activity
Sani, O. G., Yang, Y., Lee, M. B., Dawes, H. E., Chang, E. F., & Shanechi, M. M. (2018) · Nature Biotechnology · doi:10.1038/nbt.4200 · Cited by 230
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Hand Gestures Recognition Using Radar Sensors for Human-Computer-Interaction: A Review
Ahmed, S., Kallu, K. D., Ahmed, S., & Cho, S. H. (2021) · Remote Sensing · doi:10.3390/rs13030527 · Cited by 206
“Various studies have tried to decode the brain signal corresponding to hand movement and these signals can be seen through electrocorticography [28,29].”
BackgroundKrucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 187
“…of Medicine, Northwestern University, Chicago, IL, USA, 4Department of Integrative Biology and Physiology, University of California, Los Angeles, Los Angeles, CA, USA, 5Department of Neurobiology, Duke University Medical Center, Durham, NC, USA, 6 Research and Surgery Services, Durham Veterans…”
BackgroundInfluentialZhuang, Q., Yao, K., Wu, M., Lei, Z., Chen, F., Li, J., Mei, Q., Zhou, Y., Huang, Q., Zhao, X., et al. (2023) · Science Advances · doi:10.1126/sciadv.adg8602 · Cited by 172
The Potential for a Speech Brain–Computer Interface Using Chronic Electrocorticography
Rabbani, Q., Milsap, G., & Crone, N. E. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00692-2 · Cited by 126
Self-citationNason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Decoding Movement From Electrocorticographic Activity: A Review
Volkova, K., Lebedev, M. A., Kaplan, A., & Ossadtchi, A. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00074 · Cited by 110
“Classification algorithms, such as LDA (Kapeller et al., 2014; Hotson et al., 2016) and SVM (Yanagisawa et al., 2011) have been used to detect movement onset based on ECoG recordings.”
BackgroundMethodInfluentialActive upper limb prostheses: a review on current state and upcoming breakthroughs
Marinelli, A., Boccardo, N., Tessari, F., Domenico, D. D., Caserta, G., Canepa, M., Gini, G. C., Barresi, G., Laffranchi, M., Michieli, L. D., et al. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acac57 · Cited by 132
“ECoG signals have been used for hand gesture recognition (Bleichner et al 2016), for the control of a virtual prosthesis (Wang et al 2013) and of a robotic limb (Fifer et al 2013), and also with a detached prosthesis with active digits (Hotson et al 2016).”
Human motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 120
“Subsequent studies even demonstrate that continuous finger positions can also be decoded [54, 59, 61, 63, 64, 68].”
BackgroundApplications of brain-computer interfaces to the control of robotic and prosthetic arms
Vilela, M., & Hochberg, L. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00008-1 · Cited by 118
Kaiju, T., Doi, K., Yokota, M., Watanabe, K., Inoue, M., Ando, H., Takahashi, K., Yoshida, F., Hirata, M., & Suzuki, T. (2017) · Frontiers in Neural Circuits · doi:10.3389/fncir.2017.00020 · Cited by 94
“…higher electrode density, higher channel counts, and smaller electrodes (Rubehn et al., 2009; Ledochowitsch et al., 2011; Matsuo et al., 2011; Toda et al., 2011; Viventi et al., 2011; Escabí et al., 2014; Castagnola et al., 2015; Kellis et al., 2015; Khodagholy et al., 2015; Hotson et al., 2016).”
BackgroundMethodResultDegenhart, A. D., Eles, J., Dum, R., Mischel, J. L., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler-Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 94
“…and nonhuman primate subjects have demonstrated up to threedimensional control of computer cursors or prosthetic limbs using ECoG (Leuthardt et al 2004, Wilson et al 2006, Schalk et al 2008, Leuthardt et al 2011, Schalk and Lethardt 2011, Yanagisawa et al 2012, Wang et al 2013, Hotson et al 2016).”
BackgroundCaldwell, D. J., Ojemann, J. G., & Rao, R. P. N. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00804 · Cited by 81
“These principles have been applied to induce plasticity in nonhuman primate (NHP) motor cortex (Jackson et al., 2006) and rodent rehabilitation experiments, where triggering stimulation in somatosensory cortex several milliseconds after premotor cortex firing in rats that suffered from damage to…”
BackgroundDecoding EEG and LFP signals using deep learning: heading TrueNorth
Nurse, E., Mashford, B. S., Yepes, A. J., Kiral-Kornek, I., Harrer, S., & Freestone, D. R. (2016) · Proceedings of the ACM International Conference on Computing Frontiers · doi:10.1145/2903150.2903159 · Cited by 76
EEG-based brain-computer interface enables real-time robotic hand control at individual finger level
Ding, Y., Udompanyawit, C., Zhang, Y., & He, B. (2025) · Nature Communications · doi:10.1038/s41467-025-61064-x · Cited by 142
Bundled-Optode Method in Functional Near-Infrared Spectroscopy
Nguyen, H.-D., Hong, K., & Shin, Y. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165146 · Cited by 74
Lee, H. S., Schreiner, L., Jo, S.-H., Sieghartsleitner, S., Jordan, M., Pretl, H., Guger, C., & Park, H. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1009878 · Cited by 90
“Therefore, to better understand and rehabilitate the finger-related motor cortex, a considerable amount of research has been conducted (Kubánek et al., 2009; Acharya et al., 2010; Yanagisawa et al., 2011; Flamary and Rakotomamonjy, 2012; Liang and Bougrain, 2012; Hotson et al., 2016).”
BackgroundYang, D., Gu, Y., Thakor, N. V., & Liu, H. (2018) · Experimental Brain Research · doi:10.1007/s00221-018-5441-x · Cited by 76
Self-citationDeep learning for EEG-based Motor Imagery classification: Accuracy-cost trade-off
León, J., Escobar, J. J., Ortíz, A., Ortega, J., González, J., Martín-Smith, P., Gan, J. Q., & Damas, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234178 · Cited by 76
“Electrocorticography (ECoG) [10, 11] represents a partially invasive middle ground, where surgery is still needed but only to place devices on the surface of the brain.”
BackgroundContinuous decoding of human grasp kinematics using epidural and subdural signals
Flint, R. D., Rosenow, J. M., Tate, M. C., & Slutzky, M. W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016005 · Cited by 69
Brain-computer interfaces for communication
Vansteensel, M. J., & Jarosiewicz, B. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00007-x · Cited by 85
“Electrode diameter is typically 2.3mm exposed surface, with 1cm interelectrode distance, but layouts with higher density and smaller electrodes are increasingly used (Flinker et al., 2011; Bouchard et al., 2013; Bleichner et al., 2016; Hotson et al., 2016).”
MethodWelle, E. J., Patel, P. R., Woods, J. E., Petrossians, A., della Valle, E., Vega-Medina, A., Richie, J. M., Cai, D., Weiland, J. D., & Chestek, C. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8343 · Cited by 72
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
“Accuracy is generally used in BCI for binary and multi-state classification [15, 16, 30, 69, 70] and is useful for performance comparison due to its ease of computation and interpretation.”
MethodGalileo Hand: An Anthropomorphic and Affordable Upper-Limb Prosthesis
Fajardo, J. V., Ferman, V., Cardona, D., Maldonado, G., Lemus, A., & Rohmer, E. (2020) · IEEE Access · doi:10.1109/access.2020.2990881 · Cited by 80
“The main problems with this methodology are its invasiveness and price, because it requires an implant consisting of an ECoG array in the brain and a targeted muscle re-innervation (TMR) on a specific set of muscles, which results in challenging procedures for the amputees [7].”
BackgroundAlahi, M. E. E., Liu, Y., Xu, Z., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2021) · Materials Today Communications · doi:10.1016/j.mtcomm.2021.102853 · Cited by 68
Fazio, R. D., Mastronardi, V., Petruzzi, M., Vittorio, M. D., & Visconti, P. (2022) · Future Internet · doi:10.3390/fi15010014 · Cited by 65
“To obtain the best resolution, the band was placed on the biceps region [58].”
MethodAdvanced Electrode Technologies for Noninvasive Brain–Computer Interfaces
Lin, S., Jiang, J., Huang, K., Li, L., He, X., Du, P. Y., Wu, Y., Liu, J., Li, X., Huang, Z., et al. (2023) · ACS Nano · doi:10.1021/acsnano.3c06781 · Cited by 59
Degenhart, A. D., Hiremath, S. V., Yang, Y., Foldes, S., Collinger, J. L., Boninger, M., Tyler-Kabara, E. C., & Wang, W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9bfb · Cited by 52
“Apart from several notable demonstrations of prosthetic hand control [36, 86], most ECoG BCI studies have relied upon this approach.”
BackgroundNason, S. R., Mender, M. J., Vaskov, A. K., Willsey, M. S., Kumar, N. G., Kung, T. A., Patil, P. G., & Chestek, C. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.08.009 · Cited by 67
Dynamic network modeling and dimensionality reduction for human ECoG activity
Yang, Y., Sani, O. G., Chang, E. F., & Shanechi, M. M. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2214 · Cited by 53
Ahmadizadeh, C., Khoshnam, M., & Menon, C. (2021) · IEEE Signal Processing Magazine · doi:10.1109/msp.2021.3057042 · Cited by 48
Recent advances and current trends in brain‐computer interface research and their applications
Žabčíková, M., Koudelková, Z., Jašek, R., & Lorenzo-Navarro, J. (2022) · International Journal of Developmental Neuroscience · doi:10.1002/jdn.10166 · Cited by 57
“It can be, for example, control of external devices, such as limbs prostheses (Buccino et al., 2016; Edelman et al., 2016; Hotson et al., 2016; Meng et al., 2016; Vansteensel et al., 2016; Xiang et al., 2016), smart home environments (Bundy et al., 2017; Minguillon et al., 2017; Yang et al., 2018)…”
BackgroundBranco, M. P., Gaglianese, A., Glen, D., Hermes, D., Saad, Z. S., Petridou, N., & Ramsey, N. F. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.10.022 · Cited by 49
“…of the ECoG signals (Gaglianese et al., 2017; Hermes et al., 2012; Jacques et al., 2016; Ojemann et al., 2013; Siero et al., 2013), and for the design of advanced neuro-implants such as Brain-Computer Interfaces (BCIs) (Yanagisawa et al., 2012; Hotson et al., 2016; Vansteensel et al., 2016).”
BackgroundMotor Imagery Based Continuous Teleoperation Robot Control with Tactile Feedback
Bao-guo, X., Li, W., He, X., Wei, Z., Zhang, D., Wu, C., & Song, A. (2020) · Electronics · doi:10.3390/electronics9010174 · Cited by 50
“In addition, BCI-based control of virtual object [6], robotic arm [7–9], robotic prosthetic [10,11], wheelchair [12], and various rehabilitation devices [13–16] were also reported in previous research.”
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 46
“…has been used to control cursors, using biofeedback (Bundy et al. 2012; Leuthardt et al. 2004; Miller et al. 2010; Schalk et al. 2008), biomimetic (Milekovic et al. 2012), and hybrid/adaptive BMIs (Wang et al. 2013), and robotic hands and arms (Hotson et al. 2016; Yanagisawa et al. 2011, 2012).”
MethodNakanishi, Y., Yanagisawa, T., Shin, D., Kambara, H., Yoshimura, N., Tanaka, M., Fukuma, R., Kishima, H., Hirata, M., & Koike, Y. (2017) · Scientific Reports · doi:10.1038/srep45486 · Cited by 50
Rupp, K., Roos, M. J., Milsap, G., Caceres, C. A., Ratto, C. R., Chevillet, M. A., Crone, N. E., & Wolmetz, M. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.074 · Cited by 51
Self-citationFuture space missions and human enhancement: Medical and ethical challenges
Szocik, K., Shelhamer, M., Braddock, M., Cucinotta, F. A., Impey, C. D., Worden, P., Peters, T., Ćirković, M. M., Smith, K. C., Tachibana, K., et al. (2021) · Futures · doi:10.1016/j.futures.2021.102819 · Cited by 51
“There is also progress in the generation of brain-computer interface communication systems in patients who are either unable to have full movement (Hotson et al., 2016) or are unable to communicate after trauma (Chaudhary, Xia, Silvoni, Cohen & Birmbauer, 2017) or as a consequence of degenerative…”
BackgroundZheng, Y., & Hu, X. (2021) · International Journal of Neural Systems · doi:10.1142/s0129065721500106 · Cited by 44
Multichannel haptic feedback unlocks prosthetic hand dexterity
Abd, M. A., Ingicco, J., Hutchinson, D. T., Tognoli, E., & Engeberg, E. D. (2022) · Scientific Reports · doi:10.1038/s41598-022-04953-1 · Cited by 52
Yunus, R., Ali, S., Ayaz, Y., Khan, M., Kanwal, S., Akhlaque, U., & Nawaz, R. (2020) · IEEE Access · doi:10.1109/access.2020.2975149 · Cited by 46
Practical real-time MEG-based neural interfacing with optically pumped magnetometers
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Van Hulle, M. M., Bowtell, R., & Brookes, M. J. (2021) · BMC Biology · doi:10.1186/s12915-021-01073-6 · Cited by 41
Neurotechnologies to restore hand functions
Losanno, E., Mender, M. J., Chestek, C. A., Shokur, S., & Micera, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00054-4 · Cited by 49
Real-time classification of auditory sentences using evoked cortical activity in humans
Moses, D. A., Leonard, M. K., & Chang, E. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaab6f · Cited by 41
“fully used in real-time motor control applications [37, 38],”
MethodNeurophysiology and neural engineering: a review
Procházka, A. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00149.2017 · Cited by 40
“2) (Branco et al. 2017; Flint et al. 2017; Hotson et al. 2016; Leuthardt et al. 2006; Vansteensel et al. 2016; Vinjamuri et al. 2009; Wang et al. 2009), or implanted penetrating microelectrode arrays (Bouton et al. 2016; Sharma et al. 2016).”
BackgroundThe Representation of Finger Movement and Force in Human Motor and Premotor Cortices
Flint, R. D., Tate, M. C., Li, K., Templer, J. W., Rosenow, J. M., Pandarinath, C., & Slutzky, M. W. (2020) · eNeuro · doi:10.1523/eneuro.0063-20.2020 · Cited by 42
“…BMIs using motor cortical signals control robotic or prosthetic hands (Hochberg et al., 2012; Yanagisawa et al., 2012; Wodlinger et al., 2015; Hotson et al., 2016) or functional electrical stimulation of paralyzed limbs (Pfurtscheller et al., 2003; Bouton et al., 2016; Ajiboye et al., 2017).”
BackgroundRyun, S., Kim, J. S., Lee, H., & Chung, C. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-15767-x · Cited by 42
Yao, L., Zhu, B., & Shoaran, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4ed1 · Cited by 52
“Another ECoG-BMI system used a linear discriminant analysis classifier and the feature of high-gamma power (72– 110 Hz) to control a prosthetic limb [27].”
BackgroundMethodA CMOS-based highly scalable flexible neural electrode interface
Zhao, E. T., Hull, J. M., Hemed, N. M., Uluşan, H., Bartram, J., Zhang, A., Wang, P., Pham, A., Ronchi, S., Huguenard, J. R., et al. (2023) · Science Advances · doi:10.1126/sciadv.adf9524 · Cited by 38
“Neurophysiological recordings with ECoG 39 grids have been successfully used for speech synthesis (4, 5), reproduction of arm 40 movements (6), and spatial localization of ictal onset zones (7).”
MethodVirtual Integration Environment as an Advanced Prosthetic Limb Training Platform
Perry, B. N., Armiger, R. S., Yu, K. E., Alattar, A. A., Moran, C. W., Wolde, M., McFarland, K. A., Pasquina, P. F., & Tsao, J. W. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00785 · Cited by 37
Self-citationMultiscale modeling and decoding algorithms for spike-field activity
Hsieh, H.-L., Wong, Y. T., Pesaran, B., & Shanechi, M. M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaeb1a · Cited by 46
Characterization and Decoding the Spatial Patterns of Hand Extension/Flexion using High-Density ECoG
Jiang, T., Jiang, T., Wang, T., Mei, S., Liu, Q., Li, Y., Wang, X., Prabhu, S. S., Sha, Z., & Ince, N. F. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2647255 · Cited by 47
“Most recently, a human study using a 128 channel (8×16) electrode array with 3 mm contact spacing has achieved real-time control of prosthetic limb [10].”
BackgroundGoshi, N., Castagnola, E., Vomero, M., Gueli, C., Cea, C., Zucchini, E., Bjånes, D. A., Maggiolini, E., Moritz, C. T., Kassegne, S., et al. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aab061 · Cited by 42
Osborn, L. E., Moran, C. W., Johannes, M. S., Sutton, E. E., Wormley, J. M., Dohopolski, C., Nordstrom, M. J., Butkus, J., Chi, A., Pasquina, P. F., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe20d · Cited by 41
Self-citationDecoding and geometry of ten finger movements in human posterior parietal cortex and motor cortex
Guan, C., Aflalo, T., KADLEC, K. H., Gámez, J., Rosario, E. R., Bari, A., Pouratian, N., & Andersen, R. A. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd3b1 · Cited by 41
“Previously, [34] demonstrated the first”
BackgroundThe future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 38
Aquino-Brítez, D., Ortíz, A., Ortega, J., León, J., Formoso, M. A., Gan, J. Q., & Escobar, J. J. (2021) · Sensors · doi:10.3390/s21062096 · Cited by 38
“Electrocorticography (ECoG) is an example [9], which uses electrodes placed directly on the exposed surface of the brain to record electrical activity from the cortex.”
Huggins, J. E., Guger, C., Ziat, M., Zander, T. O., Taylor, D., Tangermann, M., Soria‐Frisch, A., Simeral, J. D., Scherer, R., Rupp, R., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1275488 · Cited by 34
Dalrymple, A. N., Everaert, D. G., Hu, D. S., & Mushahwar, V. K. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aad872 · Cited by 32
“They have also been used to control flexor and extensor activations in the hind-limb during treadmill stepping with epidural stimulation in monkeys (Capogrosso et al 2016), and control prosthetic arms in humans (Fetz 1999, Collinger et al 2013, Wang et al 2013, Hotson et al 2016).”
MethodAdaptive tracking of human ECoG network dynamics
Ahmadipour, P., Yang, Y., Chang, E. F., & Shanechi, M. M. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abae42 · Cited by 39
Evolution, biomechanics, and neurobiology converge to explain selective finger motor control
Xu, J., Mawase, F., & Schieber, M. H. (2024) · Physiological Reviews · doi:10.1152/physrev.00030.2023 · Cited by 36
Gruenwald, J., Znobishchev, A., Kapeller, C., Kamada, K., Scharinger, J., & Guger, C. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00901 · Cited by 32
“While the individual implementations differ considerably, feature selection is heavily used in the ECoG community (Kapeller et al., 2014; Xie et al., 2015; Bleichner et al., 2016; Hotson et al., 2016; Li et al., 2017; Pan et al., 2018).”
BackgroundMethodInfluentialAkan, Ö. B., Ramezani, H., Civas, M., Cetinkaya, O., Bilgin, B. A., & Abbasi, N. A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3056455 · Cited by 32
“Furthermore, the ECoG signal is used for offline decoding of seven degrees of freedom for arm movements in monkeys and online decoding for individual finger movements in human subjects [84], [91].”
MethodUpper limb sensorimotor restoration through brain–computer interface technology in tetraparesis
Bockbrader, M. A. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.09.002 · Cited by 29
Decoding Imagined 3D Arm Movement Trajectories From EEG to Control Two Virtual Arms—A Pilot Study
Korik, A., Sosnik, R., Siddique, N. H., & Coyle, D. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00094 · Cited by 40
“…studied as the control of a cursor in 2D (Wolpaw and McFarland, 2004), classification of finger movements in closed-loop (Lehtonen et al., 2008; Hotson et al., 2016), open and grasp of a prosthetic hand (Fukuma et al., 2015), controlling an upper-limb exoskeleton for stroke survivors (Bhagat…”
BackgroundJiang, T., Pellizzer, G., Asman, P., Bastos, D. C. A., Bhavsar, S., Tummala, S., Prabhu, S. S., & Ince, N. F. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00100 · Cited by 29
“In the ECoG study with individual finger decoding (Hotson et al., 2016), there was a large amount of overlap between channels used for motor and sensory tasks, with the majority of the electrodes used being postcentral in both cases.”
BackgroundMethodLi, G., Jiang, S., Meng, J., Chai, G., Wu, Z., Fan, Z., Hu, J. Z., Sheng, X., Zhang, D., Chen, L., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118969 · Cited by 23
Branco, M. P., de Boer, L. M., Ramsey, N. F., & Vansteensel, M. J. (2019) · European Journal of Neuroscience · doi:10.1111/ejn.14342 · Cited by 32
“Nevertheless, some studies have demonstrated that individual fingers can still be decoded with high accuracy (Hamed et al., 2007; Hotson et al., 2016; Kubanek, Miller, Ojemann, Wolpaw, & Schalk, 2009) and show a consistent ventral to dorsal activation map from thumb to little finger respectively…”
BackgroundSensing and Control for Prosthetic Hands in Clinical and Research Applications
Osborn, L. E., Iskarous, M. M., & Thakor, N. V. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00022-9 · Cited by 34
“ECoG signals have been shown to decode individual finger movements [24, 25] as well as 3 DOFs in a prosthetic arm [6].”
BackgroundSelf-citationClassification of Individual Finger Movements Using Intracortical Recordings in Human Motor Cortex
Jorge, A., Royston, D., Tyler‐Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2020) · Neurosurgery · doi:10.1093/neuros/nyaa026 · Cited by 26
Fedor, F. Z., Madarász, M., Zátonyi, A., Szabó, Á., Lőrincz, T., Danda, V. R., Spurgin, L., Manz, C., Rózsa, B. J., & Fekete, Z. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100942 · Cited by 26
Stability of motor representations after paralysis
Guan, C., Aflalo, T., Zhang, C. Y., Amoruso, E., Rosario, E. R., Pouratian, N., & Andersen, R. A. (2022) · eLife · doi:10.7554/elife.74478 · Cited by 25
Thomas, T. M., Candrea, D. N., Fifer, M. S., McMullen, D. P., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2891362 · Cited by 33
“rest and then classify among different possible movements [24].”
Self-citationUpper Limb Active Prosthetic systems—Overview
Castellini, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00019-9 · Cited by 36
Vatsyayan, R., Lee, J., Bourhis, A. M., Tchoe, Y., Cleary, D. R., Tonsfeldt, K. J., Lee, K., Montgomery‐Walsh, R., Paulk, A. C., Hoi Sang, U., et al. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00537-0 · Cited by 29
Strategies for neural control of prosthetic limbs: from electrode interfacing to 3D printing
Ngan, C., Kapsa, R. M. I., & Choong, P. (2019) · Materials · doi:10.3390/ma12121927 · Cited by 26
Candrea, D. N., Shah, S., Luo, S., Angrick, M., Rabbani, Q., Coogan, C. G., Milsap, G., Nathan, K., Wester, B. A., Anderson, W. S., et al. (2024) · Communications Medicine · doi:10.1038/s43856-024-00635-3 · Cited by 32
Self-citationLiao, J., Widmer, L., Wang, X., Mauro, A. D., Nason, S. R., Chestek, C. A., Benini, L., & Jang, T. (2022) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas54282.2022.9869846 · Cited by 24
“They are essential tools in motor rehabilitation by restoring the movement ability of amputees and tetraplegic patients [1]–[4].”
BackgroundMethodWu, X., Metcalfe, B., He, S., Tan, H., & Zhang, D. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3421551 · Cited by 27
“For example, while many studies specify the recording region as the primary motor cortex (MI) [61], [69] or primary somatosensory cortex (SI) [77], other studies referred to these areas as the sensorimotor cortex as a whole [113], [150].”
BackgroundMethodFriedenberg, D. A., Bouton, C. E., Annetta, N. V., Skomrock, N. D., Zhang, M., Schwemmer, M. A., Bockbrader, M. A., Mysiw, W. J., Rezai, A. R., Bresler, H. S., et al. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591381 · Cited by 21
“Previous work has shown that intracortically recorded signals from non-human primates and paralyzed humans can be used to control computer cursors, electronic wheelchairs, and robotic arms [2-7].”
BackgroundMcMullen, D. P., Thomas, T. M., Fifer, M. S., Candrea, D. N., Tenore, F. V., Nickl, R. W., Pohlmeyer, E. A., Coogan, C. G., Osborn, L. E., Schiavi, A. J., et al. (2021) · Journal of neurosurgery · doi:10.3171/2020.9.jns202675 · Cited by 23
Self-citationSequence Transfer Learning for Neural DecodingPreprint
Elango, V., Patel, A. N., Miller, K. J., & Gilja, V. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/210732 · Cited by 23
“As such, the stateof-the art decoders are models which only need to learn a small set of parameters (Gilja et al., 2012; Collinger et al., 2013; Hotson et al., 2016).”
BackgroundMethodInfluentialGearing, M., & Kennedy, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00111 · Cited by 21
Wang, M., Li, G., Jiang, S., Wei, Z., Hu, J. Z., Chen, L., & Zhang, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9987 · Cited by 20
“…hand kinematics regression or individual finger classification (Kubanek et al., 2009; Acharya et al., 2010; Flint et al., 2014; Nakanishi et al., 2014; Hotson et al., 2016), for functional use there is still a wide gap to bridge because it requires multi-finger coordination at much higher dimensions.”
BackgroundMovement-Related Sensorimotor High-Gamma Activity Mainly Represents Somatosensory Feedback
Ryun, S., Kim, J. S., Jeon, E., & Chung, C. K. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00408 · Cited by 20
“The 60 Hz power line noise was removed after frequency-by-frequency normalization. activation beyond somatosensory feedback (Sun et al., 2015; Hotson et al., 2016; Branco et al., 2017).”
BackgroundMethodInfluentialAn Affordable open-source multifunctional upper-limb prosthesis with intrinsic actuation
Fajardo, J. V., Ferman, V., Lemus, A., & Rohmer, E. (2017) · IEEE Workshop on Advanced Robotics and its Social Impacts (ARSO) · doi:10.1109/arso.2017.8025206 · Cited by 23
Schaeffer, M.-C., & Aksenova, T. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.03.002 · Cited by 20
User-Prosthesis Interface for Upper Limb Prosthesis Based on Object Classification
Fajardo, J. V., Ferman, V., Muñoz, A., de Andrade, D. T. G., Neto, A. R., & Rohmer, E. (2018) · Latin American Robotics Symposium, Brazilian Symposium on Robotics and Workshop on Robotics in Education (LARS/SBR/WRE) · doi:10.1109/lars/sbr/wre.2018.00076 · Cited by 21
“developed to be used in gaming that has proven its viability as a replacement of the expensive EMG devices [13,14].”
BackgroundWireless, miniaturized, semi-implantable electrocorticography microsystem validated in vivo
Keramatzadeh, K., Kiakojouri, A., Nahvi, M. S., Khazaei, Y., Feizi-nejad, A., Maghami, M. H., Mohammadi, R., Sharifshazileh, M., Nasiri, S., Boroumand, F. A., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77953-8 · Cited by 17
Lim, M. J. R., Lo, Y. T., Tan, Y. Y., Lin, H.-Y., Wang, Y., Tan, D., Wang, E., Ma, Y. Y. N., Ng, J. J. W., Jefree, R. A., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb88e · Cited by 21
“Classification algorithms, such as support vector machines and linear discriminant analysis, are effective at decoding discrete motor movements, where neural activity at a point in time is used to predict the discrete action to be performed [51–53].”
Schroeder, K. E., Irwin, Z. T., Bullard, A. J., Thompson, D. E., Bentley, J. N., Stacey, W. C., Patil, P. G., & Chestek, C. A. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7329 · Cited by 24
“In the ECoG study with the best individual finger decoding [27], there was a large amount of overlap between channels used for motor (finger tapping) and sensory (vibrotactile) tasks, with the majority of electrodes used being postcentral in both cases.”
MethodJiang, T., Liu, S., Pellizzer, G., Aydöseli, A., Karamürsel, S., Sabancı, P. A., Sencer, A., Gürses, C., & Ince, N. F. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00110 · Cited by 16
“…in terms of ERD/ERS analysis, ECoG studies using a high-density grid with smaller contact size (Marathe and Taylor, 2013; Bleichner et al., 2014; Hotson et al., 2016; Wang et al., 2016; Jiang et al., 2017a) provide comparable information, in terms of time-frequency characteristics, as studies…”
MethodResultEnhanced Classification of Individual Finger Movements with ECoG
Yao, L., & Shoaran, M. (2019) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf44664.2019.9048649 · Cited by 19
“Moreover, ECoG has been successfully used for prosthetic limb control through classifying the individual finger movements [8].”
MethodSellers, K. K., Chung, J. E., Zhou, J., Triplett, M., Dawes, H. E., Haque, R., & Chang, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1984 · Cited by 14
“…of greater density than COTS arrays: 3 mm pitch arrays were used to link neural signals to individual and synergistic finger movements [44] and decode control of individual prosthetic fingers [45]; 4 mm pitch arrays were used to map speech processing in human nonprimary auditory cortex [46].”
Sun, Q., Merino, E. C., Yang, L., & Hulle, M. M. V. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01533-4 · Cited by 22
“For example, Hotson et al. successfully decoded individual finger movements using electrocorticography (ECoG) to control a modular prosthetic limb in real-time [4].”
Feature Selection Methods for Zero-Shot Learning of Neural Activity
Caceres, C. A., Roos, M. J., Rupp, K., Milsap, G., Crone, N. E., Wolmetz, M. E., & Ratto, C. R. (2017) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2017.00041 · Cited by 15
Self-citation
Metadata
- Authors
- Hotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., & Crone, N. E.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Hotson, Guy
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-10
- Volume
- 13
- Issue
- 2
- Pages
- 026017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4875758
- OpenAlex
- W2273148818
- Semantic Scholar
- 8e9a1a51767162e8c6a9f581ca6912923d419b6b
- Cited by
- 201
- References
- 56
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 14 · 2023: 13 · 2022: 19 · 2021: 25 · 2020: 29 · 2019: 25 · 2018: 22 · 2017: 26 · 2016: 9
- FWCI
- 17.39
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (1R01NS088606-01)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, sensorimotor cortex, electrode selection
- MeSH terms
- Electrocorticography, Artificial Limbs, Electrodes, Implanted, Fingers, Humans, Male, Movement, User-Computer Interface, Vibration, Young Adult, Brain-Computer Interfaces, Sensorimotor Cortex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.