Individual finger control of a modular prosthetic limb using high-density electrocorticography in a human subject
Open accessThe DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
Abstract
Objective. We used native sensorimotor representations of fingers in a brain–machine interface (BMI) to achieve immediate online control of individual prosthetic fingers. Approach. Using high gamma responses recorded with a high-density electrocorticography (ECoG) array, we rapidly mapped the functional anatomy of cued finger movements. We used these cortical maps to select ECoG electrodes for a hierarchical linear discriminant analysis classification scheme to predict: (1) if any finger was moving, and, if so, (2) which digit was moving. To account for sensory feedback, we also mapped the spatiotemporal activation elicited by vibrotactile stimulation. Finally, we used this prediction framework to provide immediate online control over individual fingers of the Johns Hopkins University Applied Physics Laboratory modular prosthetic limb. Main results . The balanced classification accuracy for detection of movements during the online control session was 92% (chance: 50%). At the onset of movement, finger classification was 76% (chance: 20%), and 88% (chance: 25%) if the pinky and ring finger movements were coupled. Balanced accuracy of fully flexing the cued finger was 64%, and 77% had we combined pinky and ring commands. Offline decoding yielded a peak finger decoding accuracy of 96.5% (chance: 20%) when using an optimized selection of electrodes. Offline analysis demonstrated significant finger-specific activations throughout sensorimotor cortex. Activations either prior to movement onset or during sensory feedback led to discriminable finger control. Significance. Our results demonstrate the ability of ECoG-based BMIs to leverage the native functional anatomy of sensorimotor cortical populations to immediately control individual finger movements in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, the high spatial and temporal resolution of ECoG and LFPs can provide finer and more accurate control signals for prostheses as the neuronal areas can be recorded independently at a higher density.[333,334]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [333]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702 · cited 1×
“Trials were initiated by an experimenter on a presentation computer running psychtoolbox-3 [36] in MATLAB (MathWorks, Inc.”
MethodReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Porro, C. A., Francescato, M. P., Cettolo, V., Diamond, M. E., Baraldi, P., Zuiani, C., Bazzocchi, M., & di Prampero, P. E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-23-07688.1996 · Cited by 924
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Regularized linear discriminant analysis and its application in microarrays
Guo, Y., Hastie, T., & Tibshirani, R. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj035 · Cited by 597
Constraints on Somatotopic Organization in the Primary Motor Cortex
Schieber, M. H. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.5.2125 · Cited by 596 · cited 2×
“In spite of the evidence of limited finger somatotopy in motor cortex [22, 23, 25], both ECoG and fMRI studies have found a degree of separability in the peak population responses for different fingers in the precentral gyrus [26, 27].”
BackgroundEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Powell, T. P. S., & Mountcastle, V. B. (1959) · PubMed · Cited by 536
Shared Neural Substrates Controlling Hand Movements in Human Motor Cortex
Sanes, J. N., Donoghue, J. P., Thangaraj, V., Edelman, R. R., & Warach, S. (1995) · Science · doi:10.1126/science.7792606 · Cited by 471
How Somatotopic Is the Motor Cortex Hand Area?
Schieber, M. H., & Hibbard, L. S. (1993) · Science · doi:10.1126/science.8332915 · Cited by 464 · cited 3×
“In spite of the evidence of limited finger somatotopy in motor cortex [22, 23, 25], both ECoG and fMRI studies have found a degree of separability in the peak population responses for different fingers in the precentral gyrus [26, 27].”
BackgroundAn Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402 · cited 3×
“ECoG signals from hand somatosensory areas were also used in [43], where”
BackgroundMethodInfluentialBrain activation during execution and motor imagery of novel and skilled sequential hand movements
Lacourse, M. G., Orr, E. L. R., Cramer, S. C., & Cohen, M. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.025 · Cited by 367
Miller, K. J., Zanos, S., Fetz, E. E., den Nijs, M., & Ojemann, J. G. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.5506-08.2009 · Cited by 350
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Chao (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00003 · Cited by 341 · cited 1×
“In contrast, ECoG is able to deliver stable large-area coverage of sensorimotor areas [24], delivering control from multiple anatomical sites.”
BackgroundResponsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 309
Lebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285 · cited 3×
“These differential finger responses have been used to perform offline classification and reconstruction of finger movements from ECoG recordings over sensorimotor areas [1, 3].”
BackgroundMethodElectrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 2×
“used ECoG to asynchronously modulate the aperture of two grasp types (77% of trials correct to completion) while simultaneously controlling elbow movements (34% of trials correct to completion) with a prosthetic limb [11].”
MethodDecoding natural grasp types from human ECoG
Pistohl, T., Schulze-Bonhage, A., Aertsen, A., Mehring, C., & Ball, T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.084 · Cited by 249
Brain motor system function after chronic, complete spinal cord injury
Cramer, S. C., Lastra, L., Lacourse, M. G., & Cohen, M. J. (2005) · Brain · doi:10.1093/brain/awh648 · Cited by 218
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208
Christensen, M. S., Lundbye-Jensen, J., Geertsen, S. S., Petersen, T. H., Paulson, O. B., & Nielsen, J. B. (2007) · Nature Neuroscience · doi:10.1038/nn1873 · Cited by 197
McMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A. D., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 188 · cited 2×
“intelligent robotics into neural-only BMIs may allow users to perform a wide variety of tasks [41, 56].”
BackgroundSelf-citationWhat Disconnection Tells about Motor Imagery: Evidence from Paraplegic Patients
Alkadhi, H., Brugger, P., Boendermaker, S. H., Crelier, G., Curt, A., Hepp-Reymond, M.-C., & Kollias, S. S. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhh116 · Cited by 183
Mapping phantom movement representations in the motor cortex of amputees
Mercier, C. (2006) · Brain · doi:10.1093/brain/awl180 · Cited by 182
Persistent hand motor commands in the amputees' brain
Reilly, K. T. (2006) · Brain · doi:10.1093/brain/awl154 · Cited by 175
Zhuang, J., Truccolo, W., Vargas-Irwin, C., & Donoghue, J. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2047015 · Cited by 174
Boendermaker, S. H., Funk, M., Summers, P. E., Brugger, P., Hepp‐Reymond, M., Curt, A. E. P., & Kollias, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.065 · Cited by 164
Kokotilo, K. J., Eng, J. J., & Curt, A. (2009) · Journal of Neurotrauma · doi:10.1089/neu.2008.0688 · Cited by 156 · cited 2×
“We expect similar patterns of activation between paralyzed and able-bodied patients during the time period preceding somatosensory feedback, as suggested by the spatial patterns of activation seen in paralyzed patients during attempted movements [30].”
BackgroundFelton, E. A., Wilson, J. A., Williams, J. C., & Garell, P. C. (2007) · Journal of Neurosurgery · doi:10.3171/jns.2007.106.3.495 · Cited by 154
Digit Somatotopy within Cortical Areas of the Postcentral Gyrus in Humans
Nelson, A. J., & Chen, R. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm257 · Cited by 150 · cited 1×
“postcentral gyrus than in the precentral gyrus [22, 23, 25, 48, 49].”
BackgroundElectrocorticographic amplitude predicts finger positions during slow grasping motions of the hand
Acharya, S., Fifer, M. S., Benz, H. L., Crone, N. E., & Thakor, N. V. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046002 · Cited by 150 · cited 1×
“Electrocorticography (ECoG) signals recorded from sensorimotor areas have been used offline to reconstruct hand aperture [7] and classify different hand gestures [8–10].”
MethodSelf-citationCorollary discharge circuits in the primate brain
Crapse, T. B., & Sommer, M. A. (2008) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2008.09.017 · Cited by 147
Chestek, C. A., Gilja, V., Blabe, C. H., Foster, B. L., Shenoy, K. V., Parvizi, J., & Henderson, J. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026002 · Cited by 134
Siero, J. C. W., Hermes, D., Hoogduin, H. M., Luijten, P. R., Ramsey, N. F., & Petridou, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.002 · Cited by 127 · cited 1×
“In spite of the evidence of limited finger somatotopy in motor cortex [22, 23, 25], both ECoG and fMRI studies have found a degree of separability in the peak population responses for different fingers in the precentral gyrus [26, 27].”
BackgroundGeometric strategies for neuroanatomic analysis from MRI
Duncan, J. S., Papademetris, X., Yang, J., Jackowski, M. P., Zeng, X., & Staib, L. H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.027 · Cited by 125 · cited 1×
“Electrodes were localized with respect to cortical surface anatomy by volumetric co-registration of the subject’s pre-implantation MRI with their post-surgical CT using the BioImage Suite [29].”
MethodContinuous Shared Control for Stabilizing Reaching and Grasping With Brain-Machine Interfaces
Kim, H. K., Biggs, S. J., Schloerb, D. W., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., & Srinivasan, M. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870235 · Cited by 123
Wang, W., Degenhart, A. D., Collinger, J. L., Vinjamuri, R., Sudre, G. P., Adelson, P. D., Holder, D. L., Leuthardt, E. C., Moran, D. W., Boninger, M. L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333704 · Cited by 118 · cited 1×
“These differential finger responses have been used to perform offline classification and reconstruction of finger movements from ECoG recordings over sensorimotor areas [1, 3].”
MethodGritsenko, V., Krouchev, N. I., & Kalaska, J. F. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00162.2007 · Cited by 116 · cited 2×
“in this region was the result of an ‘efference copy’ sent from premotor and associated motor planning cortices [32, 50, 51].”
BackgroundResultPhantom limb imaginary fingertapping causes primary motor cortex activation: an fMRI study
Ersland, L., Rosén, G., Lundervold, A., Smievoll, A. I., Tillung, T., Sundberg, H., & ugdahl, K. (1996) · NeuroReport · doi:10.1097/00001756-199612200-00042 · Cited by 114
Shoham, D., & Grinvald, A. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-17-06820.2001 · Cited by 101
Fifer, M. S., Hotson, G., Wester, B. A., McMullen, D. P., Wang, Y., Johannes, M. S., Katyal, K. D., Helder, J. B., Para, M. P., Vogelstein, R. J., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2286955 · Cited by 88 · cited 3×
“a prosthetic limb was demonstrated with mean accuracies of 84% and 81% for reach and grasp respectively [12].”
BackgroundMethodSelf-citationDecoding M1 Neurons During Multiple Finger Movements
Hamed, S. B., Schieber, M. H., & Pouget, A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00760.2006 · Cited by 87
Give me a sign: decoding four complex hand gestures based on high-density ECoG
Bleichner, M. G., Freudenburg, Z. V., Jansma, J. M., Aarnoutse, E. J., Vansteensel, M. J., & Ramsey, N. F. (2016) · Brain Structure and Function · doi:10.1007/s00429-014-0902-x · Cited by 83
Decoding Finger Flexion from Band-Specific ECoG Signals in Humans
Liang, N., & Bougrain, L. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00091 · Cited by 79
Cortical Adaptation to a Chronic Micro-Electrocorticographic Brain Computer Interface
Rouse, A. G., Williams, J. J., Wheeler, J. J., & Moran, D. W. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.0271-12.2013 · Cited by 75
Acharya, S., Tenore, F., Aggarwal, V., Etienne-Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916269 · Cited by 74 · cited 1×
“Offline decoding of single finger movements has been achieved with MEAs in non-human primates [2, 20], but MEA recordings in humans are rare and suffer from attrition of reliable single units over time [21].”
Self-citationSun, H., Blakely, T. M., Darvas, F., Wander, J. D., Johnson, L. A., Su, D. K., Miller, K. J., Fetz, E. E., & Ojemann, J. G. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.01.005 · Cited by 65 · cited 1×
“pre-movement signals in sensory areas that were led by signals in task-related areas in premotor cortices [52].”
BackgroundDecoding Finger Movements from ECoG Signals Using Switching Linear Models
Flamary, R., & Rakotomamonjy, A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00029 · Cited by 60
Decoding fingertip trajectory from electrocorticographic signals in humans
Nakanishi, Y., Yanagisawa, T., Shin, D., Chen, C., Kambara, H., Yoshimura, N., Fukuma, R., Kishima, H., Hirata, M., & Koike, Y. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.05.005 · Cited by 59
Ultra-long term stability of single units using chronically implanted multielectrode arrays
Vaidya, M., Dickey, A. S., Best, M. D., Coles, J., Balasubramanian, K., Suminski, A. J., & Hatsopoulos, N. G. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944715 · Cited by 27
Research works printed but not linked: 2
- [28].Johannes MS, Bigelow JD, Burck JM, Harshbarger SD, Kozlowski MV, Van Doren T. An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 2011;30(no. 3):207–216. [Google Scholar]
- [56].Muelling K, Venkatraman A, Valois J-S, Downey J, Weiss J, Javdani S, Hebert M, Schwartz AB, Collinger JL, Bagnell JA. Autonomy Infused Teleoperation with Application to BCI Manipulation. ArXiv Prepr. 2015 ArXiv150305451. [Google Scholar] Associated Data This section collects any data citations, data availability statements, or supplementary materials included in this article.
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Human augmentation: Past, present and future
Raisamo, R., Rakkolainen, I., Majaranta, P., Salminen, K., Rantala, J., & Farooq, A. (2019) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2019.05.008 · Cited by 236
Mood variations decoded from multi-site intracranial human brain activity
Sani, O. G., Yang, Y., Lee, M. B., Dawes, H. E., Chang, E. F., & Shanechi, M. M. (2018) · Nature Biotechnology · doi:10.1038/nbt.4200 · Cited by 230
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Metadata
- Authors
- Hotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., & Crone, N. E.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Hotson, Guy
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-10
- Volume
- 13
- Issue
- 2
- Pages
- 026017
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC4875758
- OpenAlex
- W2273148818
- Semantic Scholar
- 8e9a1a51767162e8c6a9f581ca6912923d419b6b
- Cited by
- 201
- References
- 56
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 14 · 2023: 13 · 2022: 19 · 2021: 25 · 2020: 29 · 2019: 25 · 2018: 22 · 2017: 26 · 2016: 9
- FWCI
- 17.39
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (1R01NS088606-01)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, sensorimotor cortex, electrode selection
- MeSH terms
- Electrocorticography, Artificial Limbs, Electrodes, Implanted, Fingers, Humans, Male, Movement, User-Computer Interface, Vibration, Young Adult, Brain-Computer Interfaces, Sensorimotor Cortex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.