Feedback control policies employed by people using intracortical brain–computer interfaces
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Objective . When using an intracortical BCI (iBCI), users modulate their neural population activity to move an effector towards a target, stop accurately, and correct for movement errors. We call the rules that govern this modulation a ‘feedback control policy’. A better understanding of these policies may inform the design of higher-performing neural decoders. Approach . We studied how three participants in the BrainGate2 pilot clinical trial used an iBCI to control a cursor in a 2D target acquisition task. Participants used a velocity decoder with exponential smoothing dynamics. Through offline analyses, we characterized the users’ feedback control policies by modeling their neural activity as a function of cursor state and target position. We also tested whether users could adapt their policy to different decoder dynamics by varying the gain (speed scaling) and temporal smoothing parameters of the iBCI. Main results . We demonstrate that control policy assumptions made in previous studies do not fully describe the policies of our participants. To account for these discrepancies, we propose a new model that captures (1) how the user’s neural population activity gradually declines as the cursor approaches the target from afar, then decreases more sharply as the cursor comes into contact with the target, (2) how the user makes constant feedback corrections even when the cursor is on top of the target, and (3) how the user actively accounts for the cursor’s current velocity to avoid overshooting the target. Further, we show that users can adapt their control policy to decoder dynamics by attenuating neural modulation when the cursor gain is high and by damping the cursor velocity more strongly when the smoothing dynamics are high. Significance . Our control policy model may help to build better decoders, understand how neural activity varies during active iBCI control, and produce better simulations of closed-loop iBCI movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“More surgical details can be found in [2, 8, 28].”
BackgroundSelf-citationOptimal feedback control as a theory of motor coordination
Todorov, E., & Jordan, M. I. (2002) · Nature Neuroscience · doi:10.1038/nn963 · Cited by 3,081 · cited 1×
“Optimal feedback control theory has been used to explain certain features of human feedback control policies by assuming that these policies optimize a cost function [38 – 41].”
MethodReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“Much of the literature to date has focused on improving iBCI performance by changing how neural activity is translated into motion (i.e. ‘ decoding ’ ) [2, 4, 7 – 16].”
BackgroundSelf-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“Much of the literature to date has focused on improving iBCI performance by changing how neural activity is translated into motion (i.e. ‘ decoding ’ ) [2, 4, 7 – 16].”
BackgroundOptimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“Intracortical brain–computer interfaces (iBCIs) can restore movement and communication to people with paralysis by recording movement-related neural activity from the cortex and translating it into command signals for an external device, such as a computer cursor or a robotic arm [1 – 8].”
BackgroundNeural constraints on learning
Sadtler, P. T., Quick, K. M., Golub, M. D., Chase, S. M., Ryu, S. I., Tyler-Kabara, E. C., Yu, B. M., & Batista, A. P. (2014) · Nature · doi:10.1038/nature13665 · Cited by 713
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Self-citationSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Self-citationEvidence for the Flexible Sensorimotor Strategies Predicted by Optimal Feedback Control
Liu, D., & Todorov, E. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1110-06.2007 · Cited by 447
Clinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343 · cited 10×
“Since recent reports have showed significant performance gains enabled by using better assumptions about the user ’ s control policy to calibrate decoders [4, 8, 16, 17, 21], we expect that more refined knowledge of the user ’ s control policy could continue to improve performance.”
BackgroundInfluentialSelf-citationJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340 · cited 4×
“Much of the literature to date has focused on improving iBCI performance by changing how neural activity is translated into motion (i.e. ‘ decoding ’ ) [2, 4, 7 – 16].”
BackgroundMethodInfluentialSelf-citationFunctional network reorganization during learning in a brain-computer interface paradigm
Jarosiewicz, B., Chase, S. M., Fraser, G. W., Velliste, M., Kass, R. E., & Schwartz, A. B. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808113105 · Cited by 302
Self-citationPerge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243 · cited 1×
“To account for changes in the mean value of neural features over time that can cause an offset (bias) to appear in u t [29], we updated our estimate of the feature means over the course of the session using methods similar to Jarosiewicz et al [7].”
MethodSelf-citation
Cited by
Inferring single-trial neural population dynamics using sequential auto-encoders
Pandarinath, C., O’Shea, D. J., Collins, J., Jozefowicz, R., Stavisky, S. D., Kao, J. C., Trautmann, E. M., Kaufman, M. T., Ryu, S. I., Hochberg, L. R., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0109-9 · Cited by 686
Self-citationThe state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Self-citationBullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Willett, F. R., Murphy, B. A., Memberg, W. D., Blabe, C. H., Pandarinath, C., Walter, B. L., Sweet, J. A., Miller, J. P., Henderson, J. M., Shenoy, K. V., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5990 · Cited by 16
“We studied joystick movements made by able-bodied volunteers to confirm that (1) Fitts’ law accurately describes movement times for our random target task when the cursor is controlled by able-bodied movement, (2) that adding large J. Neural Eng. 14 (2017) 026010”
MethodSelf-citation
Metadata
- Authors
- Willett, F. R., Pandarinath, C., Jarosiewicz, B., Murphy, B. A., Memberg, W. D., Blabe, C. H., Saab, J., Walter, B. L., Sweet, J. A., Miller, J. P., Henderson, J. M., Shenoy, K. V., Simeral, J. D., Hochberg, L. R., Kirsch, R. F., & Ajiboye, A. B.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-11-30
- Volume
- 14
- Issue
- 1
- Pages
- 016001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2557316459
- Cited by
- 57
- References
- 14
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.