OBJECTIVE: Motor neural interface systems (NIS) aim to convert neural signals into motor prosthetic or assistive device control, allowing people with paralysis to regain movement or control over their immediate environment. Effector or prosthetic control can degrade if the relationship between recorded neural signals and intended motor behavior changes. Therefore, characterizing both biological and technological sources of signal variability is important for a reliable NIS. APPROACH: To address the frequency and causes of neural signal variability in a spike-based NIS, we analyzed within-day fluctuations in spiking activity and action potential amplitude recorded with silicon microelectrode arrays implanted in the motor cortex of three people with tetraplegia (BrainGate pilot clinical trial, IDE). MAIN RESULTS: 84% of the recorded units showed a statistically significant change in apparent firing rate (3.8 ± 8.71 Hz or 49% of the mean rate) across several-minute epochs of tasks performed on a single session, and 74% of the units showed a significant change in spike amplitude (3.7 ± 6.5 µV or 5.5% of mean spike amplitude). 40% of the recording sessions showed a significant correlation in the occurrence of amplitude changes across electrodes, suggesting array micro-movement. Despite the relatively frequent amplitude changes, only 15% of the observed within-day rate changes originated from recording artifacts such as spike amplitude change or electrical noise, while 85% of the rate changes most likely emerged from physiological mechanisms. Computer simulations confirmed that systematic rate changes of individual neurons could produce a directional 'bias' in the decoded neural cursor movements. Instability in apparent neuronal spike rates indeed yielded a directional bias in 56% of all performance assessments in participant cursor control (n = 2 participants, 108 and 20 assessments over two years), resulting in suboptimal performance in these sessions. SIGNIFICANCE: We anticipate that signal acquisition and decoding methods that can adapt to the reported instabilities will further improve the performance of intracortically-based NISs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the CNS, small signal amplitudes, signal instability, and signal loss over time are often observed.14,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This may undermine the detection and decoding efficacy of brain-machine interfaces and closed-loop neurostimulation applications in which the stimulus is conditioned on a recorded neural signal.1,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“any differences in average firing rates observed between two behaviors collected in separate blocks could be due to spurious drifts in firing rates known to occur across time63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
The cited source says what the claim attributes to it.
In the citing paper
“While the ‘isolated ’verbal behavior experiments (section 3) allowed us to explore a large number of behaviors, it did not allow us to assess differences in neural representation between behaviors, because any differences between blocks could also be caused by spurious neural nonstationarity known to be occur in microelectrode array recordings63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
The control of the false discovery rate in multiple testing under dependency
Benjamini, Y., & Yekutieli, D. (2001) · The Annals of Statistics · doi:10.1214/aos/1013699998 · Cited by 10,490 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“…Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform actions with a robotic limb in macaques (Velliste et al 2008) or humans (Hochberg et al 2012, Collinger et al 2012).”
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409 · cited 1×
“…to control a computer cursor on a screen in intact macaques (Ganguly and Carmena 2009, Carmena et al 2003, Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform…”
BackgroundSelf-citationTruccolo, W., Eden, U. T., Fellows, M. R., Donoghue, J. P., & Brown, E. N. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00697.2004 · Cited by 1,049 · cited 1×
“Thus modeling the observed (Truccolo et al 2005, Wu and Hatsopoulos 2008) or hidden sources of variability (Stevenson et al 2010, Lawhern et al 2010, Wood et al 2005, Kulkarni and Paninski 2007) could provide further improvement in decoding performance.”
Self-citation
Research works printed but not linked: 10
- Cornwell A S Kirsch R F, 2010, Proc. IEEE Conf. on Engineering in Medicine and Biology Society, 6222
- Flint R D Wright Z A Slutzky M W, 2012, 34th Annual Int. Conf. on the IEEE EMBS
- Homer M L Perge J A Hochberg L R, 2011, Society for Neuroscience Annu. Meeting
- Jarosiewicz B, 2013, J. Neural. Eng.
- Linderman M D Gilja V Santhanam G Afshar A Ryu S Meng T H Shenoy K V, 2006, Proc. Annual Int. Conf. on the IEEE Engineering in Medicine and Biology Society, 4387
- Nuyujukian P Kao J C Fan J M Stavisky S D Ryu S Shenoy K, 2012, COSYNE: Proc. 2012 Computational and Systems Neuroscience Conf.
- Prasad A, 2012, J. Neural. Eng., 9
- Simeral J D, 2011, Conf. Society of Neuroscience, 41
- Watkins P T Santhanam G Shenoy K V Harrison R R, 2004, Proc. Annual Int. Conf. on the IEEE Engineering in Medicine and Biology Society, 4079
- Wood F Prabhat Donoghue J Black M, 2005, Proc. Annual Int. Conf. on the IEEE Engineering in Medicine and Biology Society Conf., 149
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“There is a growing consensus in the literature that research should continue into developing better recording technologies suitable for humans (251, 271, 391, 624, 646).”
BackgroundGlial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“Many of these shifts seem to be related to device micromotion (based on simultaneous effects observed across electrode sites) 13 , but the vast majority were attributed to a physiological origin (85%).”
InfluentialUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“Evidence suggests that mechanical mismatch is an important reason leading to abrupt and chronically unstable interfaces within the brain 4, 22 .”
Background
Metadata
- Authors
- Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R.
- Affiliations
- Brown University (US)
- Harvard University (US)
- Rhode Island Hospital (US)
- Corresponding author
- Perge, János A
- Homer, Mark L
- Malik, Wasim Q
- Cash, Sydney
- Eskandar, Emad
- Friehs, Gerhard
- Donoghue, John P
- Hochberg, Leigh R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-04-10
- Volume
- 10
- Issue
- 3
- Pages
- 036004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3693851
- OpenAlex
- W2047933600
- Cited by
- 243
- References
- 67
- Citations by year
- 2026: 20 · 2025: 17 · 2024: 31 · 2023: 19 · 2022: 13 · 2021: 16 · 2020: 25 · 2019: 14 · 2018: 19 · 2017: 21 · 2016: 15 · 2015: 11 · 2014: 16 · 2013: 5
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (n01hd53403-6-0-1)
- National Institute on Deafness and Other Communication Disorders (R01DC009899)
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- National Institute of Biomedical Imaging and Bioengineering (R01EB007401)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HHSN275201100018C, N01HD10018, N01 HD053403)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- motor cortex, tetraplegia, neural decoding, recording artifacts, adaptive decoding
- MeSH terms
- Adult, Algorithms, Circadian Rhythm, Electroencephalography, Female, Humans, Male, Middle Aged, Motor Cortex, Nerve Net, Quadriplegia, Sensitivity and Specificity, Reproducibility of Results, Evoked Potentials, Motor, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intra-day signal instabilities affect decoding performance in an intracortical neural interface system. https://app.cochat.ai/papers/10.1088/1741-2560/10/3/036004
- The paper
- Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013). Intra-day signal instabilities affect decoding performance in an intracortical neural interface system. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/10/3/036004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.