Mechanical factors in the design of chronic recording intracortical microelectrodes
Abstract
To obtain chronic recordings from single nerve cells in the cerebral cortex it is necessary to prevent motion of the microelectrode tip with respect to the adjacent neural tissue. This paper presents an engineering analysis to estimate these motions in terms of the geometry and material properties of the electrode, its lead wire, and the cortex. The results are used to gain an understanding of a recently reported successful recording system, and to thereby provide a design guide for future systems. In addition, a buckling analysis is presented for a class of microelectrodes to enable a minimum size to be achieved with an adequate safety margin.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As implants fail to move together with tissue, compression and sliding along the interface cause damage to surrounding tissue.
“As implants fail to move together with tissue, the compression and sliding along the interface causes damage to the surrounding tissue (Goldstein and Salcman, 1973; Sharp et al., 2009; Barrese et al., 2016).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Goldstein and Salcman, 1973
Cites
Knops, R. J., & Wilkes, E. W. (1973) · Mechanics of Solids · doi:10.1007/978-3-642-69569-8_2 · Cited by 5,185 · see citing works
Some Basic Problems of the Mathematical Theory of Elasticity.
Lowengrub, M., & Noordhoff, N. I. M. (1967) · American Mathematical Monthly · doi:10.2307/2314307 · Cited by 1,461 · see citing works
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 495 · see citing works
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 470 · see citing works
Formulas for stress and strain
Roark, R. J. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 328 · see citing works
A comparison of the elasticity of live, dead, and fixed brain tissue
Metz, H. D., McElhaney, J. H., & Ommaya, A. K. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90017-5 · Cited by 156 · see citing works
PHYSICAL TECHNIQUES IN BIOLOGICAL RESEARCH
(1963) · Elsevier eBooks · doi:10.1016/b978-1-4831-6743-5.50006-x · Cited by 143 · see citing works
Design, Fabrication, and In Vivo Behavior of Chronic Recording Intracortical Microelectrodes
Salcman, M., & Bak, M. J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324189 · Cited by 60 · see citing works
Self-citationBrain motion during vibration of water immersed rhesus monkeys
SASS, D. J., Corrao, P., & Ommaya, A. K. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90054-6 · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · see citing works
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · see citing works
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · see citing works
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“As implants fail to move together with tissue, the compression and sliding along the interface causes damage to the surrounding tissue (Goldstein and Salcman, 1973; Sharp et al., 2009; Barrese et al., 2016).”
BackgroundProgress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · see citing works
Brain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307 · see citing works
High‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286 · see citing works
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274 · see citing works
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 148 · see citing works
Golabchi, A., Wu, B., Cao, B., Bettinger, C. J., & Cui, X. T. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119519 · Cited by 138 · see citing works
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115 · see citing works
Toward the ultimate metal microelectrode
Loeb, G. E., Peck, R. A., & Martyniuk, J. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00107-7 · Cited by 114 · see citing works
Fluidic Microactuation of Flexible Electrodes for Neural Recording
Vitale, F., Vercosa, D. G., Rodriguez, A. V., Pamulapati, S. S., Seibt, F., Lewis, E., Yan, J. S., Badhiwala, K. N., Adnan, M., Carfagni, G. R., et al. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b04184 · Cited by 114 · see citing works
Compliant intracortical implants reduce strains and strain rates in brain tissuein vivo
Sridharan, A., Nguyen, J. K., Capadona, J. R., & Muthuswamy, J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036002 · Cited by 112 · see citing works
Biomaterials—The Interfacial Problem
Hench, L. L., & Ethridge, E. C. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-004905-9.50007-4 · Cited by 105 · see citing works
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
Maynard, E. M., Fernández, E., & Normann, R. A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00159-x · Cited by 102 · see citing works
Sharafkhani, N., Kouzani, A. Z., Adams, S. D., Long, J. M., Lissorgues, G., Rousseau, L., & Orwa, J. O. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109388 · Cited by 85 · see citing works
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61 · see citing works
A new chronic recording intracortical microelectrode
Salcman, M., & Bak, M. J. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477088 · Cited by 61 · see citing works
Self-citationDesign, Fabrication, and In Vivo Behavior of Chronic Recording Intracortical Microelectrodes
Salcman, M., & Bak, M. J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324189 · Cited by 60 · see citing works
Self-citationShen, W., Karumbaiah, L., Liu, X., Saxena, T. K., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 57 · see citing works
Sillay, K. A., Kumbier, L., Ross, C., Brady, M., Alexander, A. L., Gupta, A. K., Adluru, N., Miranpuri, G. S., & Williams, J. C. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0650-0 · Cited by 54 · see citing works
How is flexible electronics advancing neuroscience research?
Chen, Y., Rommelfanger, N. J., Mahdi, A. I., Wu, X., Keene, S. T., Obaid, A., Salleo, A., Wang, H., & Hong, G. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120559 · Cited by 52 · see citing works
Hydrogel facilitated bioelectronic integration
Vo, R., Hsu, L. H. H., & Jiang, X. (2020) · Biomaterials Science · doi:10.1039/d0bm01373k · Cited by 48 · see citing works
Sommakia, S., Lee, H. C., Gaire, J., & Otto, K. J. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.005 · Cited by 47 · see citing works
Kim, T., Branner, A., Gulati, T., & Giszter, S. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045001 · Cited by 39 · see citing works
Engineering and commercialization of human-device interfaces, from bone to brain
Tate, M. L. K., Detamore, M. S., Capadona, J. R., Woolley, A. J., & Knothe, U. R. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.038 · Cited by 40 · see citing works
Singh, S., Lo, M.-C., Damodaran, V. B., Kaplan, H. M., Kohn, J., Zahn, J. D., & Shreiber, D. I. (2016) · Sensors · doi:10.3390/s16030330 · Cited by 34 · see citing works
Microfabricated intracortical extracellular matrix-microelectrodes for improving neural interfaces
Shen, W., Das, S., Vitale, F., Richardson, A. G., Ananthakrishnan, A., Struzyna, L. A., Brown, D. P., Song, N., Ramkumar, M., Lucas, T. H., et al. (2018) · Microsystems & Nanoengineering · doi:10.1038/s41378-018-0030-5 · Cited by 34 · see citing works
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 36 · see citing works
He, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 32 · see citing works
Microactuated neural probes to compensate for brain micromotion
Muthuswamy, J., Gilletti, A., Jain, T., & Okandan, M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279819 · Cited by 29 · see citing works
Biomechanical Strain Analysis at the Interface of Brain and Nanowire Electrodes on a Neural Probe
Zhu, R., Huang, G. L., Yoon, H., Smith, C. S., & Varadan, V. K. (2011) · Journal of Nanotechnology in Engineering and Medicine · doi:10.1115/1.4005484 · Cited by 23 · see citing works
Tissue micromotion induced stress around brain implants
Muthuswamy, J., Saha, R., & Gilletti, A. (2005) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2005.1548395 · Cited by 23 · see citing works
A flexible polyimide cable for implantable neural probe arrays
Cheng, M.-Y., Park, W., Yu, A., Xue, R.-F., Tan, K. L., Yu, D., Lee, S., Gan, C. L., & Je, M. (2012) · Microsystem Technologies · doi:10.1007/s00542-012-1707-6 · Cited by 16 · see citing works
An Intracortical Polyimide Microprobe With Piezoelectric-Based Stiffness Control
Sharafkhani, N., Orwa, J. O., Adams, S. D., Long, J. M., Lissorgues, G., Rousseau, L., & Kouzani, A. Z. (2022) · Journal of Applied Mechanics · doi:10.1115/1.4054979 · Cited by 15 · see citing works
MATHEMATICAL MODELING OF THE BRAIN
Tenti, G., Sivaloganathan, S., & Drake, J. M. (2008) · Neurosurgery · doi:10.1227/01.neu.0000313132.04702.ea · Cited by 11 · see citing works
Flexural characterization of carbon nanotube (CNT) yarn neural electrodes
Zhu, F., Zhu, J., Zhang, X., Wang, Y., Su, J., McCallum, G. A., Zhang, X., Sui, X., & Durand, D. M. (2019) · Materials Research Express · doi:10.1088/2053-1591/aafbf7 · Cited by 11 · see citing works
Long-term implantable flexible neural interfaces for electrophysiological monitoring
Chen, B., Lu, J., Chen, Z., Han, X., Sun, Y., Lin, X., Tang, Z., Jia, S., Xie, G., Huo, F., et al. (2024) · Journal of Materials Chemistry C · doi:10.1039/d4tc04289a · Cited by 10 · see citing works
Legéndy, C. R., Salcman, M., & Brennan, N. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90115-9 · Cited by 8 · see citing works
Self-citationMaterials and Devices for Micro-invasive Neural Interfacing
Ramadi, K. B., & Cima, M. J. (2019) · MRS Advances · doi:10.1557/adv.2019.424 · Cited by 7 · see citing works
Progress in Mechanical Modeling of Implantable Flexible Neural Probes
You, X., Bai, R., Xue, K., Zhang, Z., Wang, M., Wang, X., Wang, J., Guo, J., Shen, Q., Chang, H., et al. (2024) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2024.049047 · Cited by 6 · see citing works
Kim, T., Zhong, Y., & Giszter, S. F. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2911912 · Cited by 5 · see citing works
Trauma After Electrode Implantation
Salcman, M. (1976) · Archives of Neurology · doi:10.1001/archneur.1976.00500030071016 · Cited by 4 · see citing works
Self-citationMcDermott, M. D., Olczak, K. P., & Otto, K. J. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008336 · Cited by 3 · see citing works
NOVEL DESIGN STRATEGIES TO REDUCE THE FOREIGN BODY RESPONSE TO CENTRAL NERVOUS SYSTEM IMPLANTS
Skousen, J. L. (2012) · doi:10.13140/2.1.3896.4485 · Cited by 2 · see citing works
Lin, P., Tsao, Y., & Kuo, L. (2018) · InTech eBooks · doi:10.5772/intechopen.72659 · Cited by 1 · see citing works
Shoffstall, A. J., & Capadona, J. R. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00073-8
Coatings for Microneural Implants: Biological and Mechanical Considerations
Olczak, K. P., & Otto, K. J. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_132-1
Yoon, C., Lee, Y., Yim, G., Lee, S.-W., Lee, W., Park, Y.-G., & Park, S. (2026) · ACS Nano · doi:10.1021/acsnano.6c02201 · Cited by 1 · see citing works
- Authors
- Goldstein, S. R., & Salcman, M.
- Affiliations
- United States Department of Health and Human Services (US)
- NewYork–Presbyterian Hospital (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1973-07
- Volume
- BME-20
- Issue
- 4
- Pages
- 260-269
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1978266133
- Cited by
- 53
- References
- 9
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 4 · 2017: 2 · 2016: 4 · 2015: 2 · 2014: 4 · 2013: 1 · 2012: 3
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- intracortical microelectrodes, chronic neural recording, mechanical design, buckling analysis, electrode geometry, lead wire, cerebral cortex, single-unit recording
- MeSH terms
- Animals, Haplorhini, Biomedical Engineering, Electrodes, Implanted, Mathematics, Microelectrodes, Motion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review