The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film
Open accessAbstract
Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,415
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372
Harris, K. D., Henze, D. A., Csicsvari, J. L., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,153
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. P., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,072
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citation
Research works printed but not linked: 5
- Schmidt E, 1990, Neurophysiol. Tech., 1
- Vetter R J, 2004, IEEE Trans. Neural Syst. Rehabil. Eng., 52, 896
- 10.1088/0954-898X/9/4/001 · DOI
- Kuffler S W, 1976, A Cellular Approach to the Function of the Nervous System.
- Black J, 1999, Fundamentals of Biocompatibility
Cited by
Sorted by citations
Items 301–400 of 638
Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation
Seymour, J. P., & Kipke, D. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260528 · Cited by 35
Self-citationCaldwell, R., Mandal, H. S., Sharma, R., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d3 · Cited by 36
Li, F., Gallego, J., Tirko, N. N., Greaser, J., Bashe, D., Patel, R., Shaker, E., Valkenburg, G. E. V., Alsubhi, A. S., Wellman, S. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49709-9 · Cited by 38
Björninen, M., Siljander, A. S., Pelto, J., Hyttinen, J., Kellomäki, M., Miettinen, S., Seppänen‐Kaijansinkko, R., & Haimi, S. P. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1023-7 · Cited by 35
Borden, P. Y., Ortiz, A. D., Waiblinger, C., Sederberg, A., Morrissette, A. E., Forest, C. R., Jaeger, D., & Stanley, G. B. (2017) · Neurophotonics · doi:10.1117/1.nph.4.3.031212 · Cited by 35
Multifunctional Neural Interfaces for Closed‐Loop Control of Neural Activity
Chapman, C. A. R., Goshi, N., & Şeker, E. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703523 · Cited by 38
Selective uptake and sensing of nitrate in poly(3,4-ethylenedioxythiophene)
Rudd, S., Dalton, M., Buss, P., Treijs, A., Portmann, M., Ktoris, N., & Evans, D. (2017) · Scientific Reports · doi:10.1038/s41598-017-16939-5 · Cited by 35
Biocompatibility and functionalization of diamond for neural applications
Yang, K., & Narayan, R. J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.03.002 · Cited by 34
Migliaccio, L., Aprano, S., Iannuzzi, L., Maglione, M. G., Tassini, P., Minarini, C., Manini, P., & Pezzella, A. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600342 · Cited by 35
Semiconducting electrodes for neural interfacing: a review
Ahnood, A., Chambers, A., Gelmi, A. A., Yong, K., & Kavehei, O. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00830k · Cited by 33
Kim, K., Lee, Y., Jung, K. B., Kim, Y., Jang, E., Lee, M., Son, M., & Lee, H. J. (2024) · Advanced Materials · doi:10.1002/adma.202412953 · Cited by 30
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 38
Single walled carbon nanohorns composite for neural sensing and stimulation
Carli, S., Lambertini, L., Zucchini, E., Ciarpella, F., Scarpellini, A., Prato, M., Castagnola, E., Fadiga, L., & Ricci, D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.083 · Cited by 32
Schander, A., Strokov, S., Stemmann, H., Tebmann, T., Kreiter, A. K., & Lang, W. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2880833 · Cited by 32
Advancements in Biological Neural Interfaces Using Conducting Polymers: A Review
Parashar, K., Prajapati, D. G., McIntyre, R., & Kandasubramanian, B. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c00174 · Cited by 32
Dynamic Poly(3,4‐ethylenedioxythiophene)s Integrate Low Impedance with Redox‐Switchable Biofunction
Lin, H., Zhu, B., Wu, Y., Sekine, J., Nakao, A., Luo, S., Yamashita, Y., & Yu, H. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201703890 · Cited by 32
Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface
Bernardin, E. K., Frewin, C. L., Everly, R., Ul‐Hassan, J., & Saddow, S. E. (2018) · Micromachines · doi:10.3390/mi9080412 · Cited by 35
Dynamic Hippocampal CA2 Responses to Contextual Spatial Novelty
Bhasin, G., & Nair, I. R. (2022) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2022.923911 · Cited by 31
Neurobiochemical changes in the vicinity of a nanostructured neural implant
Bérces, Z., Tóth, K., Márton, G., Pál, I., Kováts-Megyesi, B., Fekete, Z., Ulbert, I., & Pongracz, A. (2016) · Scientific Reports · doi:10.1038/srep35944 · Cited by 31
Electrochemical Roughening of Thin-Film Platinum for Neural Probe Arrays and Biosensing Applications
Ivanovskaya, A. N., Belle, A. M., Yorita, A. M., Qian, F., Chen, S., Tooker, A., Lozada, R. G., Dahlquist, D., & Tolosa, V. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0171812jes · Cited by 33
Hess‐Dunning, A., & Tyler, D. J. (2018) · Micromachines · doi:10.3390/mi9110583 · Cited by 32
Micro/Nano Technologies for High-Density Retinal Implant
Zeng, Q., Zhao, S., Yang, H., Zhang, Y., & Wu, T. (2019) · Micromachines · doi:10.3390/mi10060419 · Cited by 32
Nanostructured PEDOT Coatings for Electrode–Neuron Integration
Zhang, Z., Tian, G., Duan, X., Chen, H., & Kim, D. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.1c00375 · Cited by 31
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 34
Advances in applied supramolecular technologies 2021–2025
Balderston, D. E., Feo, E., Leonescu, A., Stevens, M., Wilmshurst, A. M., Gale, P. A., Haynes, C. J. E., Williams, G. T., & Hiscock, J. R. (2025) · Chemical Society Reviews · doi:10.1039/d4cs01037j · Cited by 30
Zhao, Z., Gong, R., Zheng, L., & Wang, J. (2016) · Sensors · doi:10.3390/s16111851 · Cited by 29
Taking Electrons out of Bioelectronics: From Bioprotonic Transistors to Ion Channels
Strakosas, X., Selberg, J. A., Hemmatian, Z., & Rolandi, M. (2017) · Advanced Science · doi:10.1002/advs.201600527 · Cited by 30
Controlling swelling in mixed transport polymers through alkyl side-chain physical cross-linking
Siemons, N. D., Pearce, D., Yu, H., Tuladhar, S. M., LeCroy, G., Sheelamanthula, R., Hallani, R. K., Salleo, A., McCulloch, I. A., Giovannitti, A., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2306272120 · Cited by 29
PEDOT:PSS—A Key Material for Bioelectronics
Ramirez, A., van der Laan, D. P., Shah, M. B., Wang, L., Zeglio, E., & Savva, A. (2025) · Advanced Science · doi:10.1002/advs.202513480 · Cited by 36
Forcelli, P. A., Sweeney, C., Kammerich, A. D., Lee, B. C. ‐., Rubinson, L. H., Kayinamura, Y. P., Gale, K., & Rubinson, J. F. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34285 · Cited by 29
Clark, A. M., Ingold, A., Reiche, C. F., Cundy, D., Balsor, J. L., Federer, F., McAlinden, N., Cheng, Y., Rolston, J. D., Rieth, L. W., et al. (2024) · Communications Biology · doi:10.1038/s42003-024-05984-2 · Cited by 30
Adaptive Threshold Neural Spike Detector Using Stationary Wavelet Transform in CMOS
Yang, Y., Boling, C. S., Kamboh, A. M., & Mason, A. J. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2425736 · Cited by 29
In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex
Wilks, S. J., Woolley, A. J., Ouyang, L., Martin, D. C., & Otto, K. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091338 · Cited by 29
Self-citationElectronic Control over Detachment of a Self-Doped Water-Soluble Conjugated Polyelectrolyte
Persson, K. M., Gabrielsson, R., Sawatdee, A., Nilsson, D., Konradsson, P., & Magnus Berggren, A. (2014) · Langmuir · doi:10.1021/la500693d · Cited by 29
Gellan gum doped polypyrrole neural prosthetic electrode coatings
Higgins, T. M., Moulton, S. E., Gilmore, K. J., Wallace, G. G., & Panhuis, M. I. H. (2011) · Soft Matter · doi:10.1039/c1sm05063j · Cited by 29
Marzullo, T., Lehmkuhle, M. J., Gage, G. J., & Kipke, D. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2041363 · Cited by 28
Self-citationNicolai, E. N., Michelson, N. J., Settell, M. L., Hara, S. A., Trevathan, J. K., Asp, A. J., Stocking, K. C., Luján, J. L., Kozai, T. D. Y., & Ludwig, K. A. (2018) · Micromachines · doi:10.3390/mi9100494 · Cited by 26
Self-citationAdvanced materials for neural surface electrodes
Schendel, A. A., Eliceiri, K. W., & Williams, J. C. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.09.006 · Cited by 28
Electroactive biocompatible materials for nerve cell stimulation
Yang, M., Liang, Y., Gui, Q., Chen, J., & Liu, Y. (2015) · Materials Research Express · doi:10.1088/2053-1591/2/4/042001 · Cited by 28
Kang, X., Liu, J., Tian, H., Yang, B. T., NuLi, Y., & Yang, C. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.050 · Cited by 27
Çoğal, S. (2018) · Analytical Letters · doi:10.1080/00032719.2017.1387791 · Cited by 28
Murbach, J. M., Currlin, S., Widener, A. E., Tong, Y., Chhatre, S. S., Subramanian, V., Martin, D. C., Johnson, B. N., & Otto, K. J. (2018) · MRS Communications · doi:10.1557/mrc.2018.138 · Cited by 31
Self-citationElectromyogram‐Based Lip‐Reading via Unobtrusive Dry Electrodes and Machine Learning Methods
Dong, P., Song, Y., Yu, S., Zhang, Z., Mallipattu, S. K., Djurić, P. M., & Yao, S. (2023) · Small · doi:10.1002/smll.202205058 · Cited by 27
Zeng, Q., Xia, K., Zhang, Y., & Wu, T. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900356 · Cited by 27
Hyakumura, T., Robles, U. A. A., Duan, W., Villalobos, J., Adams, W. K., Poole-Warren, L. A., & Fallon, J. B. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.761525 · Cited by 26
Sui, L., Song, X., Ren, J., Cai, W., Ju, L. H., Wang, Y., Wang, L. Y., & Chen, M. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34837 · Cited by 26
Diazonium-Based Anchoring of PEDOT on Pt/Ir Electrodes via Diazonium Chemistry
Chhin, D., Polcari, D., Bodart, C., Tomasello, G., Cicoira, F., & Schougaard, S. B. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0061812jes · Cited by 25
Kwon, I. S., Kim, Y. J., Klosterman, L., Forssell, M., Fedder, G. K., & Bettinger, C. J. (2016) · Journal of Materials Chemistry B · doi:10.1039/c5tb02618k · Cited by 25
Caldwell, R., Sharma, R., Takmakov, P. A., Street, M. G., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.10.002 · Cited by 27
Robinson, J. T., Pietron, J. J., Blue, B. T., Perkins, F. K., Josberger, E. E., Deng, Y., & Rolandi, M. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc03215c · Cited by 25
Fabrication and Evaluation of Cyclic Olefin Copolymer Based Implantable Neural Electrode
Baek, C., Kim, J. J., Lee, Y., & Seo, J.-M. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2963992 · Cited by 25
Minnikanti, S., Pereira, M. G. A. G., Jaraiedi, S., Jackson, K., Costa-Neto, C. M., Li, Q., & Peixoto, N. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016002 · Cited by 25
Huang, M., Lee, S., Jo, I., Park, H., Shim, B. S., & Yoon, M. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121559 · Cited by 25
Araki, T., Yoshimoto, S., Uemura, T., Miyazaki, A., Kurihira, N., Kasai, Y., Harada, Y., Nezu, T., Iida, H., Sandbrook, J., et al. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200362 · Cited by 24
Donaldson, P. D., Navabi, Z. S., Carter, R. E., Fausner, S. M. L., Ghanbari, L., Ebner, T. J., Swisher, S. L., & Kodandaramaiah, S. B. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202200626 · Cited by 23
Abidian, M. R., Salas, L. G., Yazdan-Shahmorad, A., Marzullo, T., Martin, D. C., & Kipke, D. R. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369612 · Cited by 24
Self-citationGerasimov, J. Y., Donahue, M. J., Gao, D., Tu, D., & Fabiano, S. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00183 · Cited by 24
Strategies for neural control of prosthetic limbs: from electrode interfacing to 3D printing
Ngan, C., Kapsa, R. M. I., & Choong, P. (2019) · Materials · doi:10.3390/ma12121927 · Cited by 24
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 25
Intracranial neuronal ensemble recordings and analysis in epilepsy
Tóth, E., Fabó, D., Entz, L., Ulbert, I., & Erőss, L. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.09.028 · Cited by 23
Increasing biosensor response through hydrogel thin film deposition: Influence of hydrogel thickness
Montero, L., Gabriel, G., Guimerà‐Brunet, A., Villa, R., Gleason, K. K., & Borrós, S. (2012) · Vacuum · doi:10.1016/j.vacuum.2012.06.002 · Cited by 23
Feasibility of Neural Stimulation With Floating-Light-Activated Microelectrical Stimulators
Abdo, A., & Şahin, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2114882 · Cited by 22
A low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG
Trumpis, M., Insanally, M. N., Zou, J., Elsharif, A., Ghomashchi, A., Artan, N. S., Froemke, R. C., & Viventi, J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a82 · Cited by 26
Self-supporting carbon nanotube films as flexible neural interfaces
Krukiewicz, K., Janas, D. W., Vallejo‐Giraldo, C., & Biggs, M. J. P. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.10.157 · Cited by 23
Lee, Y., Kong, C., Chang, J. W., & Jun, S. B. (2019) · Journal of Korean Medical Science · doi:10.3346/jkms.2019.34.e24 · Cited by 23
State-aware detection of sensory stimuli in the cortex of the awake mouse
Sederberg, A., Pala, A., Zheng, H. J. V., He, B. J., & Stanley, G. B. (2019) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1006716 · Cited by 22
Inferring Neuronal Network Connectivity from Spike Data: A Temporal Datamining ApproachPreprint
Patnaik, D., SASTRY, P. S., & Unnikrishnan, K. P. (2008) · arXiv (Cornell University) · doi:10.48550/arxiv.0803.0450 · Cited by 23
Transient neurovascular interface for minimally invasive neural recording and stimulation
Fanelli, A., Ferlauto, L., Zollinger, E. G., Brina, O., Reymond, P., Machi, P., & Ghezzi, D. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202100176 · Cited by 22
Jiang, S., Song, J., Zhang, Y., Nie, M., Kim, J., Marcano, A. L., Kadlec, K. M., Mills, W. A., Yan, X., Liu, H., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c19187 · Cited by 20
Long-term flexible penetrating neural interfaces: materials, structures, and implantation
Gu, C., Jiang, J., Tao, T. H., Wei, X., & Sun, L. (2021) · Science China Information Sciences · doi:10.1007/s11432-021-3321-7 · Cited by 23
Organic microelectrode arrays for bioelectronic applications
Lu, Z., Pavia, A., Savva, A., Kergoat, L., & Owens, R. M. (2023) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2023.100726 · Cited by 23
Rembado, I., Castagnola, E., Turella, L., Ius, T., Budai, R., Ansaldo, A., Angotzi, G. N., de Bertoldi, F., Ricci, D., Škrap, M., et al. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500520 · Cited by 22
Kitto, T., Bodart, C., Rossetti, N., & Cicoira, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102284-9.00025-5 · Cited by 23
Advanced Electrical and Optical Microsystems for Biointerfacing
Obaid, S. N., Chen, Z., & Lu, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000091 · Cited by 21
Egeland, B. M., Urbanchek, M. G., Peramo, A., Richardson-Burns, S. M., Martin, D. C., Kipke, D. R., Kuzon, W. M., & Cederna, P. S. (2010) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3181f61848 · Cited by 21
Self-citationLo, C. T., Tassel, P. R. V., & Saltzman, W. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.074 · Cited by 21
Electrochemical Principles of Safe Charge Injection
Cogan, S. F., Garrett, D. J., & Green, R. A. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch3 · Cited by 24
Flexible electronic-photonic 3D integration from ultrathin polymer chiplets
Huang, Y., Li, G., Bai, T., Shin, Y., Wang, X., More, A. I., Boucher, P. O., Chandrasekaran, C., Liu, J., & Fang, H. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00344-w · Cited by 20
Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers
Etemadi, L., Mohammed, M., Thorbergsson, P. T., Ekstrand, J., Friberg, A., Granmo, M., Pettersson, L. M. E., & Schouenborg, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155109 · Cited by 22
Metal-Free Transparent Three-Dimensional Flexible Electronics by Selective Molecular Bridges
Chang, W.-S., Chang, T.-S., Wang, C., & Liao, W. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c20931 · Cited by 20
Transparent, Low‐Impedance Inkjet‐Printed PEDOT:PSS Microelectrodes for Multimodal Neuroscience
Donaldson, P. D., & Swisher, S. L. (2022) · physica status solidi (a) · doi:10.1002/pssa.202100683 · Cited by 20
Chen, G., Dodson, B., Hedges, D. M., Steffensen, S. C., Harb, J. N., Puleo, C., Galligan, C., Ashe, J. M., Vanfleet, R. R., & Davis, R. C. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00038 · Cited by 20
Magnesium-based biodegradable microelectrodes for neural recording
Zhang, C., Wen, T. H., Razak, K. A., Lin, J., Xu, C., Seo, C., Villafana, E., Jiménez, H. O. T., & Liu, H. H. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110614 · Cited by 22
Nikiforidis, G., Wustoni, S., Routier, C., Hama, A., Koklu, A., Saleh, A., Steiner, N., Druet, V., Fiumelli, H., & Inal, S. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000215 · Cited by 20
Wang, L., Ge, C., Wang, F., Guo, Z., Hong, W., Jiang, C., Ji, B., Wang, M., Li, C., Sun, B., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01650 · Cited by 20
Nash, C. K., & Fritsch, I. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03182 · Cited by 20
Material and design strategies for chronically-implantable neural probes
Liu, F., & Tian-ming Fu, B. (2025) · NPG Asia Materials · doi:10.1038/s41427-025-00613-8 · Cited by 25
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/049801 · Cited by 19
Self-citationModulation of action potentials using PEDOT:PSS conducting polymer microwires
Thourson, S. B., & Payne, C. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-11032-3 · Cited by 19
Qi, X., Du, Z. J., Zhu, L., Liu, X., Xu, H., Zhou, Z., Zhong, C., Li, S., Wang, L., & Zhang, Z. (2019) · Neuroscience Bulletin · doi:10.1007/s12264-018-0325-4 · Cited by 19
Chronically Implanted Microelectrodes Cause c-fos Expression Along Their Trajectory
Pflüger, P., Pinnell, R., Martini, N., & Hofmann, U. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01367 · Cited by 19
Stimulation of the dorsal root ganglion using an Injectrode ®
Dalrymple, A. N., Ting, J. E., Bose, R., Trevathan, J. K., Nieuwoudt, S., Lempka, S. F., Franke, M., Ludwig, K. A., Shoffstall, A. J., Fisher, L. E., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2ffb · Cited by 20
Self-citationMechanical Properties of Organic Electronic Polymers on the Nanoscale
Panchal, V., Dobryden, I., Hangen, U. D., Simatos, D., Spalek, L. J., Jacobs, I. E., Schweicher, G., Claesson, P. M., & Venkateshvaran, D. (2021) · Advanced Electronic Materials · doi:10.1002/aelm.202101019 · Cited by 19
Effective Area and Charge Density of Chondroitin Sulphate Doped PEDOT Modified Electrodes
Harris, A. R., Molino, P. J., Paolini, A. G., & Wallace, G. G. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.03.038 · Cited by 19
Flexible organic transistors for neural activity recording
Xu, W. M., Wang, J., Cheng, S., & Xu, X. (2022) · Applied Physics Reviews · doi:10.1063/5.0102401 · Cited by 18
Multifunctional Nanomesh Enables Cellular‐Resolution, Elastic Neuroelectronics
Ryu, J., Qiang, Y., Chen, L., Li, G., Han, X., Woon, E., Bai, T., Qi, Y., Zhang, S., Liou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202403141 · Cited by 20
Tegtmeier, K., Aliuos, P., Lenarz, T., & Doll, T. (2016) · Physics in Medicine · doi:10.1016/j.phmed.2016.04.001 · Cited by 18
Multiphoton microfabrication of conducting polymer-based biomaterials
Hardy, J. G., Hernandez, D. S., Cummings, D. M., Edwards, F. A., Shear, J. B., & Schmidt, C. E. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00104h · Cited by 18
Francoeur, M. J., Tang, T., Fakhraei, L., Wu, X., Hulyalkar, S., Cramer, J., Buscher, N., & Ramanathan, D. R. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.678103 · Cited by 16
Array-wide uniform PEDOT:PSS electroplating from potentiostatic deposition
Shin, Y., Ryu, J., Bai, T., Qiang, Y., Qi, Y., Li, G., Huang, Y., Seo, K. J., & Fang, H. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116418 · Cited by 17
Metadata
- Authors
- Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Dow Chemical (United States) (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-03-01
- Volume
- 3
- Issue
- 1
- Pages
- 59-70
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2057005089
- Cited by
- 638
- References
- 55
- Citations by year
- 2026: 15 · 2025: 24 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 37 · 2020: 34 · 2019: 39 · 2018: 52 · 2017: 57 · 2016: 42 · 2015: 51 · 2014: 38 · 2013: 32 · 2012: 24
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866, 0518079, 0084304)
- University of Michigan
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (N01 NS 12338)
- Division of Materials Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, conducting polymer coatings, chronic neural recording, electrodeposition, electrode impedance, signal-to-noise ratio, local field potentials, low-frequency drift
- MeSH terms
- Action Potentials, Animals, Electrochemistry, Electrodes, Implanted, Equipment Design, Male, Membranes, Artificial, Microelectrodes, Motor Cortex, Neurons, Polymers, Silicon, Time Factors, Rats, Sprague-Dawley, Monitoring, Ambulatory, Bridged Bicyclo Compounds, Heterocyclic, Equipment Failure Analysis, Coated Materials, Biocompatible, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review