The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film
Open accessAbstract
Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,415
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372
Harris, K. D., Henze, D. A., Csicsvari, J. L., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,153
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. P., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,072
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citation
Research works printed but not linked: 5
- Schmidt E, 1990, Neurophysiol. Tech., 1
- Vetter R J, 2004, IEEE Trans. Neural Syst. Rehabil. Eng., 52, 896
- 10.1088/0954-898X/9/4/001 · DOI
- Kuffler S W, 1976, A Cellular Approach to the Function of the Nervous System.
- Black J, 1999, Fundamentals of Biocompatibility
Cited by
Sorted by citations
Items 401–500 of 638
Xu, Q., Xi, Y., Wang, L., Du, Z., Xu, M., Ruan, T., Cao, J., Zheng, K., Wang, X., Yang, B. T., et al. (2024) · ACS Nano · doi:10.1021/acsnano.4c07379 · Cited by 19
Electrochemical impedance spectroscopy in vivo for neurotechnology and bioelectronics
Hazelgrove, B., Matter, L., Raos, B. J., Harland, B. C., Cheng, L. K., Asplund, M., & Svirskis, D. M. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-024-00126-6 · Cited by 16
Moxon, K. A., Hallman, S. J., Sundarakrishnan, A., Wheatley, M. A., Nissanov, J., & Barbee, K. A. (2009) · Materials · doi:10.3390/ma2041762 · Cited by 16
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Marzullo, T., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046009 · Cited by 17
Self-citationIntracortical polyimide electrodes with a bioresorbable coating
Hassler, C., Guy, J., Nietzschmann, M., Plachta, D. T. T., Staiger, J. F., & Stieglitz, T. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0106-7 · Cited by 17
Yang, Y., & Mason, A. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2590560 · Cited by 17
PEDOT coated microelectrode arrays for chronic neural recording and stimulation
Venkatraman, S., Hendricks, J. L., Richardson-Burns, S. M., Jan, E., Martin, D. C., & Carmena, J. M. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109313 · Cited by 17
Self-citationGolabchi, A., Wu, B., Du, Z. J., & Cui, X. T. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202400114 · Cited by 16
Kim, H., Kim, J. H., Lee, Y. J., Lee, J., Han, H., Yi, H., Kim, H., Kim, H., Kang, T. W., Chung, S., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2419304122 · Cited by 16
A wireless forehead e-tattoo for mental workload estimation
Huh, H., Shin, H., Li, H., Hirota, K., Hoang, C., Thangavel, S., D'Alessandro, M. R., Feltman, K. A., Sentis, L., & Lu, N. (2025) · Device · doi:10.1016/j.device.2025.100781 · Cited by 19
Electrodeposited PEDOT:BF 4 Coatings Improve Impedance of Chronic Neural Stimulating Probes In Vivo
Hagler, J., Yeu, J., Zhou, X., Ducharme, G., Amilhon, B., & Cicoira, F. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202201066 · Cited by 17
Ultrasonically actuated neural probes for reduced trauma and inflammation in mouse brain
Chen, P., Young, C. G., Schaffer, C. B., & Lal, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00438-3 · Cited by 18
Jiang, J., Willett, F. R., & Taylor, D. M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944265 · Cited by 16
Schander, A., Stemmann, H., Kreiter, A. K., & Lang, W. (2018) · Micromachines · doi:10.3390/mi9030131 · Cited by 16
Lee, D., Moon, H. C., Tran, B.-T., Kwon, D.-H., Kim, Y. H., Jung, S., Joo, J. H., & Park, Y. S. (2018) · Experimental Neurobiology · doi:10.5607/en.2018.27.6.593 · Cited by 16
Verification of a Rapidly Multiplexed Circuit for Scalable Action Potential Recording
Sharma, M., Strathman, H. J., & Walker, R. M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2958348 · Cited by 16
Servello, D., Galbiati, T. F., Iess, G., Minafra, B., Porta, M., & Pacchetti, C. (2023) · Acta Neurochirurgica · doi:10.1007/s00701-023-05799-w · Cited by 17
McCarthy, P. T., Rao, M. P., & Otto, K. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046007 · Cited by 15
Castagnola, E., Maiolo, L., Maggiolini, E., Minotti, A., Marrani, M., Maita, F., Pecora, A., Angotzi, G. N., Ansaldo, A., Fadiga, L., et al. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696087 · Cited by 15
Micro-wrinkle strategy for stable soft neural interface with optimized electroplated PEDOT:PSS
Ji, B., & Wang, M. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aba5db · Cited by 15
Biomimetic Sensing – Actuators Based on Conducting Polymers
Arias‐Pardilla, J., Otero, T. F., Martínez, J. G., & Ismail, Y. A. (2012) · InTech eBooks · doi:10.5772/29348 · Cited by 15
Jeong, J., Jung, W., Kim, O., Chu, J.-U., Youn, I., Kim, K., Oh, S. R., Park, J. W., & Kim, J. (2016) · 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523786 · Cited by 14
Hassarati, R. T., Marçal, H., John, L., Foster, R., & Green, R. A. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33497 · Cited by 14
Protein-mediated synthesis of the conducting polymer PEDOT:PSS
Hira, S. M., & Payne, C. K. (2013) · Synthetic Metals · doi:10.1016/j.synthmet.2013.05.023 · Cited by 14
Genetic Modulation at the Neural Microelectrode Interface: Methods and Applications
Winter, B. M., Daniels, S. R., Salatino, J. W., & Purcell, E. K. (2018) · Micromachines · doi:10.3390/mi9100476 · Cited by 14
Anisotropic Growth of Conducting Polymers along Heparin-Modified Surfaces
Nishizawa, M., Kamiya, T., Nozaki, H., & Kaji, H. (2007) · Langmuir · doi:10.1021/la700716f · Cited by 14
μECoG Recordings Through a Thinned Skull
Brodnick, S. K., Ness, J. P., Richner, T. J., Thongpang, S., Novello, J., Hayat, M. R., Cheng, K. P., Krugner-Higby, L. A., Suminski, A. J., Ludwig, K. A., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01017 · Cited by 15
Self-citationZhou, J., Panikkanvalappil, S. R., Kang, S., Yu, S., Zhang, S., El‐Sayed, M. A., & Tsukruk, V. V. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b07018 · Cited by 14
Fast wave propagation in auditory cortex of an awake cat using a chronic microelectrode array
Witte, R. S., Rousche, P. J., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/007 · Cited by 14
Self-citationWang, M., Ye, F., Li, L., Wen, F., Guo, B., Jin, M., Xu, J., Zhou, Y., Kang, X., Ji, B., et al. (2022) · Micromachines · doi:10.3390/mi13020199 · Cited by 13
Lin, T., Lo, W.-Y., Kao, T., Lin, C., Wu, Y., & Luo, S. (2022) · Polymer · doi:10.1016/j.polymer.2022.125507 · Cited by 13
Impact of Impedance Levels on Recording Quality in Flexible Neural Probes
Han, J., Choi, J., Jeong, H., Park, D., Cheong, E., Sung, J., & Choi, H. (2024) · Sensors · doi:10.3390/s24072300 · Cited by 13
Aqrawe, Z., Patel, N. D., Vyas, Y., Bansal, M., Montgomery, J. M., Travaš‐Sejdić, J., & Svirskis, D. M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237709 · Cited by 13
Direct local polymerization of poly(3,4-ethylenedioxythiophene) in rat cortex
Ouyang, L., Green, R. A., Feldman, K. E., & Martin, D. C. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00001-7 · Cited by 13
Self-citationInsertion of a three dimensional silicon microelectrode assembly through a thick meningeal membrane
Escamilla-Mackert, T., Langhals, N. B., Kozai, T. D. Y., & Kipke, D. R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333221 · Cited by 13
Self-citation3D porous nanostructured platinum prepared using atomic layer deposition
Sree, S. P., Dendooven, J., Geerts, L., Ramachandran, R. K., Javon, E., Ceyssens, F., Breynaert, E., Kirschhock, C. E. A., Puers, R., Altantzis, T., et al. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta03257a · Cited by 13
Bong, J., Ness, J. P., Zeng, W., Kim, H., Novello, J., Pisaniello, J. A., Lake, W. B., Ludwig, K. A., Williams, J. C., Ma, Z., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111493 · Cited by 13
Self-citationCell viability and cytotoxicity of inkjet-printed flexible organic electrodes on parylene C
Mandelli, J. S., Koepp, J., Hama, A., Sanaur, S., Rae, G. A., & Rambo, C. R. (2021) · Biomedical Microdevices · doi:10.1007/s10544-020-00542-z · Cited by 13
Organic Bioelectronics: Diversity of Electronics Along with Biosciences
Moiz, S. A., Alshaikh, M. S., & Alahmadi, A. N. M. (2025) · Biosensors · doi:10.3390/bios15090587 · Cited by 16
Lee, C.-J., Wang, H., Young, M., Li, S., Cheng, F., Cong, H., & Cheng, G. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.06.002 · Cited by 12
Abdullah, A., & Krukiewicz, K. (2023) · Electrochimica Acta · doi:10.1016/j.electacta.2023.143191 · Cited by 12
Resorbable conductive materials for optimally interfacing medical devices with the living
Sacchi, M., Sauter-Starace, F., Mailley, P., & Texier, I. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1294238 · Cited by 14
Forciniti, L., Guimard, N. K., Lee, S., & Schmidt, C. E. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm01015d · Cited by 12
Fabrication of iridium oxide neural electrodes at the wafer level
Zhang, H., Pei, W., Zhao, S., Yang, X., Liu, R., Liu, Y., Wu, X. M., Guo, D., Gui, Q., Guo, X., et al. (2016) · Science China Technological Sciences · doi:10.1007/s11431-016-6099-x · Cited by 12
Large-Scale, High-Resolution Microelectrode Arrays for Interrogation of Neurons and Networks
Obien, M. E. J., & Frey, U. (2019) · Advances in neurobiology · doi:10.1007/978-3-030-11135-9_4 · Cited by 12
Conducting polymer electrodes for visual prostheses
Green, R. A., Devillaine, F., Dodds, C. W. D., Matteucci, P. B., Chen, S. C., Byrnes-Preston, P., Poole-Warren, L. A., Lovell, N. H., & Suaning, G. J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5625993 · Cited by 12
Tooker, A., Liu, D. F., Anderson, E. B., Felix, S. H., Shah, K. G., Lee, K. Y., Chung, J. E., Pannu, S. S., Frank, L. M., & Tolosa, V. M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945197 · Cited by 12
Microelectrode Arrays: Architecture, Challenges and Engineering Solutions
Khudhair, D., Nahavandi, S., Garmestani, H., & Bhatti, A. (2017) · Series in bioengineering · doi:10.1007/978-981-10-3957-7_2 · Cited by 11
Tong, Y., Murbach, J. M., Subramanian, V., Chhatre, S. S., Delgado, F., Martin, D. C., Otto, K. J., Romero‐Ortega, M. I., & Johnson, B. N. (2018) · MRS Advances · doi:10.1557/adv.2018.378 · Cited by 12
Self-citationSridharan, A., Kodibagkar, V. D., & Muthuswamy, J. (2019) · MRS Advances · doi:10.1557/adv.2019.356 · Cited by 12
Baker, C., Wagner, K. K., Wagner, P., Officer, D. L., & Mawad, D. (2021) · Advances in Physics X · doi:10.1080/23746149.2021.1899850 · Cited by 12
Effective area and charge density of dextran sulphate doped PEDOT modified electrodes
Harris, A. R., Molino, P. J., Kapsa, R. M. I., Clark, G. M., Paolini, A. G., & Wallace, G. G. (2016) · Synthetic Metals · doi:10.1016/j.synthmet.2016.07.010 · Cited by 12
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Jing, L., Xu, Z., Fan, P., Lu, B., Mo, F., Hu, R., Xu, W., Shan, J., Jia, Q., Zhu, Y., et al. (2024) · Bio-Design and Manufacturing · doi:10.1007/s42242-023-00266-y · Cited by 12
Deshmukh, A., Settell, M. L., Cheng, K. P., Knudsen, B. E., Trevathan, J. K., LaLuzerne, M., Blanz, S. L., Skubal, A. C., Verma, N., Romanauski, B., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad7f8b · Cited by 11
Self-citationUltra‐Flexible µ‐ECoG Arrays Based on PEDOT:PSS Micropillars
Lunghi, A., Bianchi, M., Greco, P., Viaro, R., Lauro, M. D., Fadiga, L., & Biscarini, F. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500051 · Cited by 12
Fabrication of vertically aligned PEDOT nanotube arrays on microelectrodes to interface neurons
Chen, H., Tian, G., Yan, H., Yang, S., & Kim, D. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.139583 · Cited by 11
Electrically Conductive Materials for Nerve Regeneration
Steel, E. M., & Sundararaghavan, H. G. (2016) · Springer eBooks · doi:10.1007/978-3-319-31433-4_5 · Cited by 11
A Microfluidic Platform to Study Astrocyte Adhesion on Nanoporous Gold Thin Films
Hampe, A. E., Li, Z., Sethi, S., Lein, P. J., & Şeker, E. (2018) · Nanomaterials · doi:10.3390/nano8070452 · Cited by 11
Carbon-Nanotube-Coated Surface Electrodes for Cortical Recordings In Vivo
Foremny, K., Konerding, W. S., Behrens, A., Baumhoff, P., Froriep, U. P., Kral, A., & Doll, T. (2021) · Nanomaterials · doi:10.3390/nano11041029 · Cited by 11
Sridharan, A., & Muthuswamy, J. (2021) · Micromachines · doi:10.3390/mi12070761 · Cited by 11
Mian, A., Newaz, G. M., Mahmood, T., & Auner, G. W. (2007) · Journal of Materials Science · doi:10.1007/s10853-007-1703-x · Cited by 11
Moghadam, M. T. T., & Cysewska, K. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad6074 · Cited by 10
Xu, Q., Wang, L., Xi, Y., Ruan, T., Cao, J., Xu, M., Zheng, K., Du, Z., Wei, N., Wang, X., et al. (2025) · Small · doi:10.1002/smll.202407950 · Cited by 10
Cornuéjols, R., Albon, A., Joshi, S. N., Taylor, J. A., Bača, M., Drakopoulou, S., Barkat, T. R., Bernard, C., & Rezaei‐Mazinani, S. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c00553 · Cited by 10
Zhang, Y., Chen, Y., Contera, S., & Compton, R. G. (2023) · ACS Applied Polymer Materials · doi:10.1021/acsapm.3c00861 · Cited by 10
Highly Doped Polycrystalline Silicon Microelectrodes Reduce Noise in Neuronal Recordings In Vivo
Saha, R., Jackson, N., Patel, C., & Muthuswamy, J. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2056389 · Cited by 10
Plastic neuronal probes for implantation in cortical and subcortical areas of the rat brain
Ismailova, E., Doublet, T., Khodagholy, D., Quilichini, P., Ghestem, A., Yang, S. Y., Bernard, C., & Malliaras, G. G. (2012) · International Journal of Nanotechnology · doi:10.1504/ijnt.2012.045351 · Cited by 10
Morris, J. D., Wong, K. M., Peñaherrera, C. D., & Payne, C. K. (2015) · Biomaterials Science · doi:10.1039/c5bm00399g · Cited by 10
Natural Materials for Organic Electronics
Irimia‐Vladu, M., Głowacki, E. D., Sariçiftçi, N. S., & Bauer, S. (2013) · Springer series in materials science · doi:10.1007/978-3-642-33848-9_12 · Cited by 10
Qiao, S., Stieglitz, T., & Yoshida, K. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2489924 · Cited by 8
Layer-dependent stability of intracortical recordings and neuronal cell loss
Urdaneta, M. E., Kunigk, N. G., Peñaloza-Aponte, J., Currlin, S., Malone, I. G., Fried, S. I., & Otto, K. J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1096097 · Cited by 10
Harris, A. R., Morgan, S. J., Wallace, G. G., & Paolini, A. G. (2014) · Journal of Visualized Experiments · doi:10.3791/51084 · Cited by 9
Bansal, M., Sharma, M., Bullen, C., & Svirskis, D. M. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.12.002 · Cited by 9
Evaluation of Amorphous Silicon Carbide on Utah Electrode Arrays by Thermal Accelerated Aging
Nguyen, C. K., Abbott, J. R., Negi, S., & Cogan, S. F. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629701 · Cited by 9
Design of electrodes for stimulation and recording
Howell, B. L., & Grill, W. M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00004-5 · Cited by 9
Ceyssens, F., Sree, S. P., Martens, J. A., & Puers, R. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.08.635 · Cited by 9
Electroactive Polymeric Biomaterials
Povlich, L. K., Feldman, K. E., Shim, B. S., & Martin, D. C. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00042-8 · Cited by 9
Self-citationAl-Attar, A. M. (2010) · International Journal of Zoological Research · doi:10.3923/ijzr.2010.199.213 · Cited by 9
Does impedance matter when recording spikes with polytrodes?Preprint
Neto, J. P., Baião, P., Lopes, G., Frazão, J., Nogueira, J., Fortunato, E. M. C., Barquinha, P. M. C., & Kampff, A. R. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/270058 · Cited by 9
Coquart, P., Haddad, A. E., Koutsouras, D. A., & Bolander, J. (2025) · Biosensors · doi:10.3390/bios15040253 · Cited by 11
Extreme manufacturing of minimally invasive intracortical neural electrodes
Xu, M., Zhu, Z., Ma, H., Zhou, G., Iliasov, A., Chen, Z., Tsang, W. M., Wu, J., Li, C., Wei, X., et al. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ae2579 · Cited by 8
Biosynthetic conductive polymer composites for tissue-engineering biomedical devices
Green, R. A., & Goding, J. A. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-105-4.00011-0 · Cited by 8
Peteu, S. F., Banihani, S. A., Gunesekera, M. M., Peiris, P. M., Sicuia, O. A. B., & Bayachou, M. (2011) · ACS symposium series · doi:10.1021/bk-2011-1083.ch011 · Cited by 8
Bhat, A., Graham, A. R., Trivedi, H., Hogan, M., Horner, P. J., & Guiseppi‐Elie, A. (2020) · Pure and Applied Chemistry · doi:10.1515/pac-2019-1107 · Cited by 8
Tresco, P. A., & Gerhardt, G. A. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8705-9_3 · Cited by 8
Saha, R., & Muthuswamy, J. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9039-x · Cited by 8
Electrodeposition of PEDOT:ClO 4 on non-noble tungsten microwire for nerve and brain recordings
Güemes, A., Dominguez‐Alfaro, A., Mizuta, R., Velasco‐Bosom, S., Carnicer‐Lombarte, A., Barone, D. G., Mecerreyes, D., & Malliaras, G. G. (2023) · Materials Advances · doi:10.1039/d3ma00949a · Cited by 7
Pérez-Nava, A., Hernández-Acosta, I., González‐Campos, J. B., & Frontana‐Uribe, B. A. (2025) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2025.109105 · Cited by 7
Heme protein-mediated synthesis of PEDOT:PSS: enhancing conductivity by inhibiting heme degradation
Flores, J. J., Payne, C. K., & Morris, J. D. (2017) · RSC Advances · doi:10.1039/c7ra00887b · Cited by 7
Pepłowski, A., Rathi, S., Piotrkowski, B., Ziółkowski, R., Janczak, D., Krzemiński, J., Brosch, M., & Jakubowska, M. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594235 · Cited by 7
Active Control of Dye Release for Neuronal Tracing Using PEDOT-PSS Coated Electrodes
Heizmann, S., Kilias, A., Ruther, P., Egert, U., & Asplund, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2606559 · Cited by 7
Advanced organic electroactive nanomaterials for biomedical use
Zuppolini, S., Guarino, V., & Borriello, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816865-3.00006-8 · Cited by 7
Wang, M., Guo, B., Ji, B., Ye, F., Wang, L., Ye, L., Chen, Y., Cheng, Y., Dong, L., & Wang, G. (2021) · IEEE Electron Device Letters · doi:10.1109/led.2021.3051617 · Cited by 7
Kilohertz Electrical Stimulation Nerve Conduction Block: Effects of Electrode Material
Patel, Y., Kim, B. S., & Butera, R. J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2737954 · Cited by 8
Open-architecture Neural Probes Reduce Cellular Encapsulation
Seymour, J. P., & Kipke, D. R. (2006) · MRS Proceedings · doi:10.1557/proc-0926-cc02-04 · Cited by 7
Self-citationProof of Concept for Sustainable Manufacturing of Neural Electrode Array for In Vivo Recording
Li, S.-Y., Tseng, H.-Y., Chen, B., Lo, Y., Shao, H.-H., Wu, Y.-T., Li, S., Chang, C.-W., Liu, T., Hsieh, F.-Y., et al. (2023) · Biosensors · doi:10.3390/bios13020280 · Cited by 7
Microfabricated nerve–electrode interfaces in neural prosthetics and neural engineering
Song, Y., Ibrahim, A. M. S., Rabie, A. N., Han, J., & Lin, S. J. (2013) · Biotechnology and Genetic Engineering Reviews · doi:10.1080/02648725.2013.801231 · Cited by 6
PEDOT:PSS coated gold nanopillar microelectrodes for neural interfaces
Nick, C., Thielemann, C., & Schlaak, H. F. (2014) · IEEE International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO) · doi:10.1109/3m-nano.2014.7057309 · Cited by 6
Boutte, R. W., & Blair, S. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0140-5 · Cited by 6
Metadata
- Authors
- Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Dow Chemical (United States) (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-03-01
- Volume
- 3
- Issue
- 1
- Pages
- 59-70
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2057005089
- Cited by
- 638
- References
- 55
- Citations by year
- 2026: 15 · 2025: 24 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 37 · 2020: 34 · 2019: 39 · 2018: 52 · 2017: 57 · 2016: 42 · 2015: 51 · 2014: 38 · 2013: 32 · 2012: 24
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866, 0518079, 0084304)
- University of Michigan
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (N01 NS 12338)
- Division of Materials Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, conducting polymer coatings, chronic neural recording, electrodeposition, electrode impedance, signal-to-noise ratio, local field potentials, low-frequency drift
- MeSH terms
- Action Potentials, Animals, Electrochemistry, Electrodes, Implanted, Equipment Design, Male, Membranes, Artificial, Microelectrodes, Motor Cortex, Neurons, Polymers, Silicon, Time Factors, Rats, Sprague-Dawley, Monitoring, Ambulatory, Bridged Bicyclo Compounds, Heterocyclic, Equipment Failure Analysis, Coated Materials, Biocompatible, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review