Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film
Open accessAbstract
Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,415
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372
Harris, K. D., Henze, D. A., Csicsvari, J. L., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,153
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. P., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,072
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citation
Research works printed but not linked: 5
- Schmidt E, 1990, Neurophysiol. Tech., 1
- Vetter R J, 2004, IEEE Trans. Neural Syst. Rehabil. Eng., 52, 896
- 10.1088/0954-898X/9/4/001 · DOI
- Kuffler S W, 1976, A Cellular Approach to the Function of the Nervous System.
- Black J, 1999, Fundamentals of Biocompatibility
Cited by
Sorted by citations
Items 501–600 of 638
Microstructure and thermoelectric properties of In2O3/poly(3, 4-ethylenedioxythiophene) composites
Ying, T., Ning, Q., Bo, W., Zhi-Quan, C., & Xin-Feng, T. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20180382 · Cited by 6
Charkhkar, H., Knaack, G. L., Mandal, H. S., Keefer, E. W., & Pancrazio, J. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943630 · Cited by 6
Electrode–Neural Tissue Interactions: Immune Responses, Current Technologies, and Future Directions
Kim, G. B., Fattahi, P., & Abidian, M. R. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch19 · Cited by 6
Conducting Polymers to Control and Monitor Cells
Jimison, L. H., Rivnay, J., & Owens, R. M. (2013) · Organic Electronics · doi:10.1002/9783527650965.ch02 · Cited by 6
Magnetoelectric Composites for Bionics Applications
Zheng, T., Zong, Y., Yue, Z., Wallace, G. G., & Higgins, M. J. (2017) · doi:10.1002/9783527801336.ch6b · Cited by 6
Herzhoff, R., Plein, L., Troisi, A., Meerholz, K., & Fazzi, D. (2025) · Materials Horizons · doi:10.1039/d5mh00610d · Cited by 5
Conjugated polymers atypically prepared in water
Invernale, M. A., Pendergraph, S. A., Yavuz, M. S., Ombaba, M., & Sotzing, G. A. (2010) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.23972 · Cited by 5
Implantable neural spike detection using lifting-based stationary wavelet transform
Yang, Y., & Mason, A. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091701 · Cited by 5
Nunes, J., Santos, R., Loureiro, V., & Piedade, A. P. (2012) · Plasma Processes and Polymers · doi:10.1002/ppap.201100089 · Cited by 5
Sui, X., Han, Z., Zhou, D., & Ren, Q. (2012) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000034 · Cited by 5
Conducting Polymer-Based Electrodes for Controlling Cellular Functions
Nishizawa, M., Kitazume, T., & Kaji, H. (2008) · Electrochemistry · doi:10.5796/electrochemistry.76.532 · Cited by 5
Suzuki, M., Nakayama, M., Tsuji, K., ADACHI, T., & Shimono, K. (2016) · Electrochemistry · doi:10.5796/electrochemistry.84.354 · Cited by 5
Prospects for a Robust Cortical Recording Interface
Shoffstall, A. J., & Capadona, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00028-0 · Cited by 5
Profound alterations in brain tissue linked to hypoxic episode after device implantation
Kumosa, L. S., & Schouenborg, J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121143 · Cited by 5
The Biocompatibility of Intracortical Microelectrode Recording Arrays for Brain Machine Interfacing
Skousen, J. L., & Tresco, P. A. (2017) · Series on bioengineering and biomedical engineering · doi:10.1142/9789813207158_0011 · Cited by 5
Kosugi, A., Takemi, M., Tia, B., Castagnola, E., Ansaldo, A., Sato, K., Awiszus, F., Seki, K., Ricci, D., Fadiga, L., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab307 · Cited by 5
Nanostructured Conductive Polymers as Biomaterials
Green, R. A., Baek, S., Lovell, N. H., & Poole-Warren, L. A. (2010) · doi:10.1002/9780470661338.ch18 · Cited by 5
Emerging Implantable Sensor Technologies at the Intersection of Engineering and Brain Science
Qi, L., Wang, Y., & Liang, X. (2025) · Biosensors · doi:10.3390/bios15110762 · Cited by 4
Flexible Neural Probe with an Optimized Electrode Density for Neutral Investigations
Park, S., Lee, H., Kim, M., Chou, N., & Shin, H. (2025) · ACS Omega · doi:10.1021/acsomega.5c02700 · Cited by 4
Clearly, Graphene is the New Gold
Stacey, W. C. (2015) · Epiliepsy currents/Epilepsy currents · doi:10.5698/1535-7511-15.6.351 · Cited by 4
Iridium Oxide-Platinum Nanocomposite Coating for Neural Electrode
Zeng, Q., Wu, T., Sun, B., Xia, K., & Humayun, M. S. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612214 · Cited by 4
Spin-orbit interactions may relax the rigid conditions leading to flat bands
Kucska, N., & Gulácsi, Z. (2022) · Physical review. B./Physical review. B · doi:10.1103/physrevb.105.085103 · Cited by 4
Otero, T. F., Martínez, J. G., Valero, L., Asaka, K., & Ismail, Y. A. (2012) · Advances in science and technology · doi:10.4028/www.scientific.net/ast.79.16 · Cited by 4
Conducting Polymers in Biological Systems
SoAoducho, J., & Cabaj, J. (2016) · Medicinal Chemistry · doi:10.4172/2161-0444.1000395 · Cited by 4
Freeze Drying Improves the Shelf-Life of Conductive Polymer Modified Neural Electrodes
Mandal, H. S., Cliff, R. O., & Pancrazio, J. J. (2015) · Bioengineering · doi:10.3390/bioengineering2030176 · Cited by 4
Fuzzy characterization of spike synchrony in parallel spike trains
Muiño, D. P., León, I. C., & Borgelt, C. (2013) · Soft Computing · doi:10.1007/s00500-013-1034-6 · Cited by 4
System and Circuit Design for Biologically-Inspired Intelligent Learning
Temel, T. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1 · Cited by 4
STEER: 3D Printed Guide for Nerve Regrowth Control and Neural Interface in Non-Human Primate Model
Blasiak, A., Ng, K. A., Wong, M. D. S., Tsai, C.-W., Rusly, A., Gammad, G. G. L., Voges, K., Libedinsky, C., Yen, S., Thakor, N. V., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3113653 · Cited by 4
Designing a Neural Interface System to Restore Mobility
Donoghue, J. P., & Hochberg, L. R. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00020-3 · Cited by 4
Green, R. A. (2022) · UNSWorks (UNSW Sydney) · doi:10.26190/unsworks/18844 · Cited by 4
Folch, A. (2016) · CRC Press eBooks · doi:10.1201/b12263-12 · Cited by 4
Wu, C., Gao, C., Jin, Q., Lu, M., Zhao, X., He, Y., Chu, D., & Bai, W. (2025) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2025.184015 · Cited by 3
Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes
Maziz, A., Cointe, C., Reig, B., & Bergaud, C. (2026) · Sensors · doi:10.3390/s26030877 · Cited by 3
Won, S., Binder, S., Boyadzhiev, A. M., Zhou, Q., Vafaei, A., Botero, J., Lim, T., Angelucci, A., Blair, S., Fan, Y., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c07028 · Cited by 3
Polymer Composites for Biomedical Applications
Praharaj, R., & Rautray, T. R. (2024) · Engineering materials · doi:10.1007/978-981-97-2075-0_16 · Cited by 3
In vitro biological assessment of electrode materials for neural interfaces
Gilmour, A. D., Goding, J. A., Poole-Warren, L. A., Thomson, C. E., & Green, R. A. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146656 · Cited by 3
Pre-saccadic Neural Enhancements in Marmoset Area MT
Coop, S. H., Yates, J. L., & Mitchell, J. F. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.2034-22.2023 · Cited by 3
Rejuvenating silicon probes for acute neurophysiology
Shoup, A. M., Porwal, N., Fakharian, M. A., Hage, P., Orozco, S. P., & Shadmehr, R. (2024) · Journal of Neurophysiology · doi:10.1152/jn.00121.2024 · Cited by 3
Shang, S., Xu, Y., Jin, M., Ni, C., Jiang, H., Wang, X., Wang, X., Cheng, Y., Wang, M., Zhang, S., et al. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136891 · Cited by 3
Self-citationTools for Surface Treatment of Silicon Planar Intracortical Microelectrodes
Krebs, O. K., Mittal, G., Ramani, S., Zhang, J., Shoffstall, A. J., Cogan, S. F., Pancrazio, J. J., & Capadona, J. R. (2022) · Journal of Visualized Experiments · doi:10.3791/63500 · Cited by 3
In Vitro and In Vivo Recording of Local Field Potential Oscillations in Mouse Hippocampus
Forsyth, L. H., Witton, J., Brown, J. T., Randall, A. D., & Jones, M. W. (2012) · Current Protocols in Mouse Biology · doi:10.1002/9780470942390.mo120089 · Cited by 3
Ultrasonically enabled neural probes with co-located electrical and mechanical transduction
Chen, P., Clark, C. G., Schaffer, C. B., Gilmour, R. F., & Lal, A. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0086 · Cited by 3
Nanowire based flexible electrode array with pedot film for neural recordings
Ryu, M., Lee, K. H., Sim, M., Kim, S., Jun, B. O., Jang, J. E., Ahn, Y., & Lee, Y. (2015) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano.2015.7388751 · Cited by 3
Yang, Y., Boling, S., Eftekhar, A., Paraskevopoulou, S. E., Constandinou, T. G., & Mason, A. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943824 · Cited by 3
Electrochemomechanical Devices: Artificial Muscles
Otero, T. F., & Arias‐Pardilla, J. (2010) · doi:10.1002/9783527630592.ch12 · Cited by 3
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 3
Nanoelectronics for Neuroscience
Rastogi, S. K., & Cohen‐Karni, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99893-3 · Cited by 3
A Biomimetic Adaptive Algorithm and Micropower Circuit Architecture for Implantable Neural Decoders
Rapoport, B. I., & Sarpeshkar, R. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1.ch010 · Cited by 2
Sederberg, A., Pala, A., & Stanley, G. B. (2024) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2024.1445621 · Cited by 2
Zhou, Z., Hu, Z., & Lyu, H. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb5c4 · Cited by 2
Shaw, L. H., Padmanabhan, K., Bucklaew, A., Mitchell, J. F., & Wang, K. H. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101368 · Cited by 3
Perspectives of Conductive Polymers Toward Smart Biomaterials for Tissue Engineering
Filimon, A. (2016) · InTech eBooks · doi:10.5772/63555 · Cited by 2
Strokov, S., Schander, A., Stemmann, H., Tebmann, T., Lang, W., & Kreiter, A. K. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234432 · Cited by 2
Conjugated Polymers for Neural Interfaces : Prospects, possibilities and future challenges
Asplund, M. (2009) · Cited by 2
Developing Chitosan-based Biomaterials for Brain Repair and Neuroprosthetics
Cao, Z. H. (2010) · Cited by 2
Development of a Neural Interface for PNS Motor Control
Christopher, G., Melinda, K. S., Luo, V. M., Jeffrey, D., & Bonnie, L. F. (2011) · InTech eBooks · doi:10.5772/23896 · Cited by 2
Yu, Y., & Lo, R.-C. (2009) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2009.5305298 · Cited by 2
1.29 Electroactive Polymeric Biomaterials ☆
Povlich, L. K., Feldman, K. E., Wei, B., Eom, T., Shim, B. S., & Martin, D. C. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10233-4 · Cited by 2
Self-citationFlexible, biocompatible, highly scalable, high charge density 3D Microelectrode arrays
Kumar, G. D. V. S., Singh, S. G., & Vanjari, S. R. K. (2016) · IEEE International Conference on Emerging Electronics (ICEE) · doi:10.1109/icemelec.2016.8074612 · Cited by 2
Advances and Perspectives on Organic Materials for Neuroelectronic Interface Devices★
Jia, L., Zhan, Z., He, Z., Di, C., & Zhu, D. (2023) · 化学学报 · doi:10.6023/a23050213 · Cited by 2
Pless, B., & Goodman, A. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00022-x · Cited by 2
Implantation of Elongated Porous Silicon Neural Probe Array in Rat CortexPreprint
Hajj-Hassan, M., Fayad, R., Berro, S., Chodavarapu, V. P., & Musallam, S. (2018) · Preprints.org · doi:10.20944/preprints201801.0080.v1 · Cited by 1
Conducting Polymers: Developments
Yazdimamaghani, M., Davachi, S. M., Amrollahi, P., Vashaee, D., & Tayebi, L. (2016) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120050030 · Cited by 2
Rejuvenating silicon probes for acute electrophysiologyPreprint
Shoup, A. M., Porwal, N., Fakharian, M. A., Hage, P., Orozco, S. P., & Shadmehr, R. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.02.20.581222 · Cited by 2
Design of Electrodes for Efficient and Selective Electrical Stimulation of Nervous Tissue
Howell, B. L. (2015) · DukeSpace (Duke University) · Cited by 2
Carbon-Nanotube-Modified Glass Micropipette for Simultaneous Drug Injection and Neural Monitoring
Shin, J. H., Kim, G. H., Kim, I., Lim, H. C., & Lim, G. (2013) · Journal of Sensor Science and Technology · doi:10.5369/jsst.2013.22.5.309 · Cited by 1
Zhou, Z., Hu, Z., & Lyu, H. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558305 · Cited by 1
Spatial richness of neural magnetic fields
Ali, Z., & Poon, A. S. Y. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1014283 · Cited by 1
Byun, J., Lee, J., Ryu, H. R., Lee, G. J., Lee, S., Kim, S. J., & Jeon, N. L. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401470 · Cited by 1
Toward Long-Term Bioelectronic Interfaces: Mechanical Compliance Meets Immunocompatibility
Zhu, Z., Zhou, X., Yin, Y., Ji, J., Wang, Y., & Zhang, P. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c13701 · Cited by 1
Xie, Y., Hassler, C., Stieglitz, T., Seifert, A., & Hofmann, U. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2038913 · Cited by 1
Implantable Brain Interface: High-Density Microelectrode Array for Neural Recording
Jun, S. B. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_4 · Cited by 1
Introduction and Literature Review
Mirabedini, A. (2018) · Springer theses · doi:10.1007/978-3-319-95378-6_1 · Cited by 1
ULTRASONIC NEURAL PROBE FOR REAL TIME ELECTROMECHANICAL HISTOLOGY OF NEURAL INTERFACES
Chen, P. C., Shen, C.-C., Kuo, J. C., Clark, C. G., Nijjar, B., Schaffer, C. B., Gilmour, R. F., & Lal, A. (2012) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2012.10 · Cited by 1
Effect of ionic conduction under dielectric barriers on PEDOT:PSS electrochemical interfaces
Jimbo, Y., Lee, W., Nishinaka, M., Yokota, T., & Someya, T. (2021) · Applied Physics Express · doi:10.35848/1882-0786/abe165 · Cited by 1
Dual Mode Neural Probe with Enhanced Microstructure for Neural Stimulation and Recording
Wang, L., Wang, F., Guo, Z., Xi, Y., Yang, B. T., & Liu, J. (2021) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers50396.2021.9495683 · Cited by 1
Polyravas, A. G., Proctor, C. M., Curto, V. F., Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_106 · Cited by 1
Robbins, C., Eles, J. R., Zheng, X. S., Kozai, T. D. Y., Cui, X. T., & Vazquez, A. L. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada0eb · Cited by 1
Yu, Y., & Lo, R.-C. (2013) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237213500282 · Cited by 1
Biophysics/ Engineering of Cortical Electrodes
Troyk, P. R. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_11 · Cited by 1
Lab on chip microdevices for cellular mechanotransduction in urothelial cells
Maziz, A., Guan, N., Svennersten, K., Hallén, K., & Jager, E. W. H. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2218799 · Cited by 1
Yun, H., Bian, C., Wang, J., Tong, J., & Xia, S. (2016) · International Conference on Sensing Technology · doi:10.1109/icsenst.2016.7796317 · Cited by 1
Advanced applications of green materials in bioelectronics applications
Yılmaz, T., & Kuş, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820484-9.00024-6 · Cited by 1
Laiwalla, F., Leung, V., Lee, J.-H., Mercier, P. P., Asbeck, P. M., Rao, R. R., Larson, L. E., & Nurmikko, A. V. (2021) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-60460-8_4 · Cited by 1
Cortical surface recurrent brain-computer interfaces
Zanos, S. P. (2013) · ResearchWorks at the University of Washington (University of Washington) · Cited by 1
Nanotexturisation of gold surfaces and its application to neural implants
Frommhold, A. (2011) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Polymer-Based Approaches to Improve the Long Term Performance of Intracortical Neural Interfaces
Hassler, C., & Stieglitz, T. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_32 · Cited by 1
Development and Characterization of Anti-Inflammatory Coatings for Implanted Neural Probes
Zhong, Y. (2006) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Smith, A. S. T., Choi, E., Gray, K., Macadangdang, J. R., Ahn, E. H., Clark, E. C., Tyler, P., Laflamme, M. A., Tung, L., Wu, J. C., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/453886 · Cited by 1
Strategies for Optimizing Information Extraction from Cortical Recordings.
Langhals, N. B. (2011) · Deep Blue (University of Michigan) · Cited by 1
A neuromuscular junction-based neural interface
Langhammer, C. G. (2010) · Rutgers University Community Repository (Rutgers University) · doi:10.7282/t3cc10d2
Regenerative Peripheral Neurointerfacing Of Upper Extremity Prostheses
Garde, K. (2008) · UTA ResearchCommons (University of Texas Arlington)
Park, S. J., Lee, Y. J., Yun, K., Kang, J. Y., & Lee, S. H. (2015) · Journal of Sensor Science and Technology · doi:10.5369/jsst.2015.24.1.22
Baldwin, J., Washabaugh, E. P., Moon, J. D., Shim, B. S., Martin, D. C., Cederna, P. S., Langhals, N. B., & Urbanchek, M. G. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696220
Self-citationA Direct Visual and Motor Neural Interface Demonstration in a Rat
Marzullo, T., Kim, E. D., Lehmkuhle, M. J., & Kipke, D. R. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369598
Self-citationA graphene oxide nanocomposite for neural interfacing applications
Weaver, C. L. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Sessolo, M., Ramuz, M. P., Malliaras, G. G., & Owens, R. M. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.013
Device Materials, Handling, and Upgradability
Kast, J., Molnar, G., & Lent, M. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381409-8.00009-7
Metadata
- Authors
- Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Dow Chemical (United States) (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2006-03-01
- Volume
- 3
- Issue
- 1
- Pages
- 59-70
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2057005089
- Cited by
- 638
- References
- 55
- Citations by year
- 2026: 15 · 2025: 24 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 37 · 2020: 34 · 2019: 39 · 2018: 52 · 2017: 57 · 2016: 42 · 2015: 51 · 2014: 38 · 2013: 32 · 2012: 24
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866, 0518079, 0084304)
- University of Michigan
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (N01 NS 12338)
- Division of Materials Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, conducting polymer coatings, chronic neural recording, electrodeposition, electrode impedance, signal-to-noise ratio, local field potentials, low-frequency drift
- MeSH terms
- Action Potentials, Animals, Electrochemistry, Electrodes, Implanted, Equipment Design, Male, Membranes, Artificial, Microelectrodes, Motor Cortex, Neurons, Polymers, Silicon, Time Factors, Rats, Sprague-Dawley, Monitoring, Ambulatory, Bridged Bicyclo Compounds, Heterocyclic, Equipment Failure Analysis, Coated Materials, Biocompatible, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review