Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Several approaches have been proposed for placement of retinal prostheses: epiretinal, subretinal and suprachoroidal. We aimed to systematically evaluate the effectiveness of varying a range of stimulus parameters and electrode geometry for a suprachoroidal electrode array, using cortical evoked responses to monopolar electrical stimulation in cats. Our results indicate that charge thresholds were not dependent on electrode size, pulse widths or position of the return electrode tested, but were dependent on the number of sites stimulated in parallel. Further, we found that the combination of monopolar stimulation with large diameter electrodes, wide pulse widths and parallel stimulation minimized the voltage requirements for stimulation. These results provide useful insights for the design specifications of a low voltage suprachoroidal stimulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marr, D., & Hildreth, E. (1980) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1980.0020 · Cited by 6,510 · cited 1×
“Together these data are compatible with convergence within the visual system for the perception of edges (Marr and Hildreth 1980).”
ResultReceptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653 · cited 1×
“The spacing between rows was 0.8 mm and the site spacing on each row was 1 mm (approximately 4◦ visual angle in cats, Hubel and Wiesel 1959; 3.5◦ visual angle in humans, Drasdo and Fowler 1974).”
BackgroundInfluentialRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“In addition, Rizzo et al (2003) using multiple current sources were able to simultaneously stimulate groups of electrode sites in human patients which were perceived as distinct patterns.”
BackgroundFactors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109 · cited 7×
“…et al 2006; approximately 10 ms, Elfar et al 2009), suprachoroidal stimulation in cats and rabbits using similar arrays (9 ± 1 ms, Sakaguchi et al 2004; 10.5 ± 0.6 ms, Wong et al 2009; 16 ± 2 ms, Nakauchi et al 2005), and extraocular stimulation in cats (approximately 8 ms, Chowdhury et al 2005).”
BackgroundMethodResultSelf-citation
Cited by
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216
“Based on the safety of this approach, the STS system has been adopted by several other groups.(22,23) In an acute clinical trial with STS prosthesis, localized phosphenes were perceived with safety currents ( 1 mA) in two patients with advanced RP.”
MethodVisual prostheses for the blind
Shepherd, R. K., Shivdasani, M. N., Nayagam, D. A. X., Williams, C. E., & Blamey, P. J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.07.001 · Cited by 178
Self-citationFujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Self-citation
Metadata
- Authors
- Shivdasani, M. N., Luu, C. D., Cicione, R., Fallon, J. B., Allen, P. J., Leuenberger, J., Suaning, G. J., Lovell, N. H., Shepherd, R. K., & Williams, C. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-05-18
- Volume
- 7
- Issue
- 3
- Pages
- 036008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2016368254
- Cited by
- 86
- References
- 5
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.