Testing of Semichronically Implanted Retinal Prosthesis by Suprachoroidal-Transretinal Stimulation in Patients with Retinitis Pigmentosa
Abstract
PURPOSE: To examine the safety and effectiveness of a retinal prosthesis that is implanted semichronically in two patients with advanced retinitis pigmentosa (RP). METHODS: Two eyes of two patients with advanced RP had a retinal prosthesis implanted in a sclera pocket of one eye. The visual acuity of both eyes before the implantation was bare light perception. Phosphenes were elicited by suprachoroidal-transretinal stimulation (STS). The internal devices of the STS were implanted under the skin on the temporal side of the head, and the 49 electrode-array was implanted in the scleral pocket of one eye. Biphasic electrical pulses (duration, 0.5 ms; frequency, 20 Hz) were delivered through nine active electrodes. The threshold current was determined by currents ≤1 mA. Behavioral tasks were used to determine the functioning of the prosthesis. RESULTS: The surgery was completed without a retinal detachment and retinal/vitreous hemorrhage. The implanted STS system remained functional for the 4-week test period. Phosphenes were elicited by currents delivered through six electrodes in Patient 1 and through four electrodes in Patient 2. The success of discriminating two bars was better than the chance level in both patients. In Patient 2, the success of a grasping task was better than the chance level, and the success rate of identifying a white bar on a touch panel increased with repeated testing. CONCLUSIONS: Semichronic implantation of a microelectrode-STS system showed that it was safe and remained functional for at least 4 weeks in two patients with advanced RP. (www.umin.ac.jp/ctr number, R000002690.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 2×
“Zrenner’s group implanted a 1500 channel electrode array subretinally, and the patient was able to recognize simple words or Landolt’s Cs.19,20 Although, the resolution of the image might be lower with STS prosthesis because the electrodes are some distance from the retina, the advantage of the STS prosthesis over the…”
MethodRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Sakaguchi, H., Kamei, M., Fujikado, T., Yonezawa, E., Ozawa, M., Cecilia-Gonzalez, C., Ustariz-Gonzalez, O., Quiroz-Mercado, H., & Tano, Y. (2009) · Journal of Artificial Organs · doi:10.1007/s10047-009-0467-2 · Cited by 58
Self-citation
Cited by
Dias, M. F., Joo, K., Kemp, J. A., Fialho, S. L., da Silva Cunha, A., Woo, S. J., & Kwon, Y. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.004 · Cited by 413
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
“To date, clinical trials have been performed with devices in the A: epiretinal position [15], B: subretinal space [7] and D: intrascleral space [19].”
MethodRetinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“in Japan, was tested in 2 RP patients in 2011 (Fujikado et al., 2011).”
An update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223
Self-citation
Metadata
- Authors
- Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., Ozawa, M., & Nishida, K.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-06-30
- Volume
- 52
- Issue
- 7
- Pages
- 4726
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2021851162
- Cited by
- 216
- References
- 4
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testing of Semichronically Implanted Retinal Prosthesis by Suprachoroidal-Transretinal Stimulation in Patients with Retinitis Pigmentosa. https://app.cochat.ai/papers/10.1167/iovs.10-6836
- The paper
- Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., Ozawa, M., & Nishida, K. (2011). Testing of Semichronically Implanted Retinal Prosthesis by Suprachoroidal-Transretinal Stimulation in Patients with Retinitis Pigmentosa. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-6836
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.