Evaluation of novel stimulus waveforms for deep brain stimulation
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Deep brain stimulation (DBS) is an established therapy for the treatment of a wide range of neurological disorders. Historically, DBS and other neurostimulation technologies have relied on rectangular stimulation waveforms to impose their effects on the nervous system. Recent work has suggested that non-rectangular waveforms may have advantages over the traditional rectangular pulse. Therefore, we used detailed computer models to compare a range of charge-balanced biphasic waveforms with rectangular, exponential, triangular, Gaussian and sinusoidal stimulus pulse shapes. We explored the neural activation energy of these waveforms for both intracellular and extracellular current-controlled stimulation conditions. In the context of extracellular stimulation, we compared their effects on both axonal fibers of passage and projection neurons. Finally, we evaluated the impact of delivering the waveforms through a clinical DBS electrode, as opposed to a theoretical point source. Our results suggest that DBS with a 1 ms centered-triangular pulse can decrease energy consumption by 64% when compared with the standard 100 µs rectangular pulse (energy cost of 48 and 133 nJ, respectively, to stimulate 50% of a distributed population of axons) and can decrease energy consumption by 10% when compared with the most energy efficient rectangular pulse (1.25 ms duration). In turn, there may be measureable energy savings when using appropriately designed non-rectangular pulses in clinical DBS applications, thereby warranting further experimental investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“However, the factors underlying stimulation induced tissue damage remain under debate, and no conclusive predictions can be made on their safety based on charge injection alone (Merrill et al., 2005).”
BackgroundCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 2×
“On the other hand, increased charge injection has been shown to correlate with tissue injury (McCreery et al., 1990; Shannon, 1992).”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 2×
“Therefore, we investigated the chargerelated safety constraints on energy efficient waveforms, demonstrating increased energy efficiency without injurious charge injection (Shannon 1992).”
BackgroundAxons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm
Wongsarnpigoon, A., & Grill, W. M. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046009 · Cited by 166
Cited by
Promises and limitations of human intracranial electroencephalography
Parvizi, J., & Kastner, S. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0108-2 · Cited by 631
Mechanisms of deep brain stimulation
Herrington, T. M., Cheng, J. J., & Eskandar, E. N. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00281.2015 · Cited by 551
“In theory, nonsquare stimulation waveforms, conditioning pulses, and other modifications to stimulation parameters could offer greater efficiency and selectivity for specific neural elements (Foutz and McIntyre 2010; Hofmann et al. 2011; Wongsarnpigoon and Grill 2010).”
BackgroundPrinciples of electrical stimulation of neural tissue
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00001-2 · Cited by 151
Energy-optimal electrical-stimulation pulses shaped by the least-action principle
Krouchev, N. I., Danner, S. M., Vinet, A., Rattay, F., & Sawan, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090480 · Cited by 29
Metadata
- Authors
- Foutz, T. J., & McIntyre, C. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-11-17
- Volume
- 7
- Issue
- 6
- Pages
- 066008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1993758650
- Cited by
- 158
- References
- 15
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of novel stimulus waveforms for deep brain stimulation. https://app.cochat.ai/papers/10.1088/1741-2560/7/6/066008
- The paper
- Foutz, T. J., & McIntyre, C. C. (2010). Evaluation of novel stimulus waveforms for deep brain stimulation. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/7/6/066008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.