Optimizing the P300-based brain–computer interface: current status, limitations and future directions
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
This paper summarizes the presentations and discussions at a workshop held during the Fourth International BCI Meeting charged with reviewing and evaluating the current state, limitations and future development of P300-based brain-computer interface (P300-BCI) systems. We reviewed such issues as potential users, recording methods, stimulus presentation paradigms, feature extraction and classification algorithms, and applications. A summary of the discussions and the panel's recommendations for each of these aspects are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“…main visual paradigms for the P300-BCI: The original, and most commonly used, is the row / column paradigm (RC) (Donchin et al 2000, Farwell and Donchin 1988), where the rows and columns of a visual matrix are flashed in a random order while the user attends to his / her desired selection…”
BackgroundMethodDonchin, E. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01815.x · Cited by 1,848 · cited 2×
“The P300 is not modality specific and can also be elicited by auditory or tactile stimuli (Donchin 1981), although the visual paradigm is the primary choice for most P300-BCI systems as it allows the presentation of multiple stimuli simultaneously.”
BackgroundThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222 · cited 1×
“To date, there are three main visual paradigms for the P300-BCI: The original, and most commonly used, is the row / column paradigm (RC) (Donchin et al 2000, Farwell and Donchin 1988), where the rows and columns of a visual matrix are flashed in a random order while the user attends to his / her…”
MethodSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 1×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundConvolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725 · cited 1×
“…(Taheri et al 1994, Fonseca et al 2007, Popescu et al 2007, Gargiulo et al 2010) offers a more convenient way for recording brain signals and may enhance the usability of the P300-BCI system, as long as signal quality is comparable (Searle and Kirkup 2000) with that of standard EEG wet electrodes.”
BackgroundA P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711 · cited 1×
“P300-BCI-related publications have been dominated by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al…”
BackgroundHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 1×
“The SC paradigm elicits a larger P300 (Guan et al 2004), but accuracy and speed of communication are reported to be lower than that of RC (Guger et al 2009).”
BackgroundA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 1×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundEysenck, H. J. (1994) · Personality and Individual Differences · doi:10.1016/0191-8869(94)90039-6 · Cited by 603
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 3×
“In the checkerboard paradigm (CB) (Townsend et al 2010), groups of matrix elements are flashed in a quasi-random pattern that controls for directly adjacent flashes and double flashes (i.e. two consecutive flashes of one single element within the matrix).”
BackgroundResultxDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 1×
“These includes methods based on orthogonal linear transformation (Dien et al 2003), blind source separation (Xu et al 2004, Li et al 2009a, Li et al 2009b), wavelet transform (Quian Quiroga and Garcia 2003, Bostanov and Kotchoubey 2006) and other advanced techniques (Rivet et al 2009).”
MethodBCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512 · cited 1×
“…studies have attempted to enhance the classification algorithm by linear methods (Bostanov 2004, Krusienski et al 2006), nonlinear methods (Krusienski et al 2006, Kaper et al 2004), neural network (Cecotti and Graser (at press)), and a combination of classifiers (Rakotomamonjy and Guigue 2008).”
MethodSellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
BCI Competition 2003—Data Set IIb: Support Vector Machines for the P300 Speller Paradigm
Kaper, M., Meinicke, P., Grossekathoefer, U., Lingner, T., & Ritter, H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826698 · Cited by 496 · cited 1×
“…studies have attempted to enhance the classification algorithm by linear methods (Bostanov 2004, Krusienski et al 2006), nonlinear methods (Krusienski et al 2006, Kaper et al 2004), neural network (Cecotti and Graser (at press)), and a combination of classifiers (Rakotomamonjy and Guigue 2008).”
MethodRemoval of Movement Artifact From High-Density EEG Recorded During Walking and Running
Gwin, J. T., Gramann, K., Makeig, S., & Ferris, D. P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00105.2010 · Cited by 481 · cited 1×
“Different methods have been proposed to remove common sources of artifacts in raw EEG signals such as eye movement (Mennes et al 2010), eye blink (Li et al 2006), muscle contraction (Gao et al 2010) and body movement (Gwin et al 2010).”
MethodFabiani, M., Gratton, G., Karis, D., & Donchin, E. (1987) · Digital Commons - University of South Florida (University of South Florida) · Cited by 458
Kübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441 · cited 1×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al…”
BackgroundA brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400 · cited 5×
“Most P300-BCI studies among the disabled community have evaluated subjects diagnosed with amyotrophic lateral sclerosis (ALS).”
BackgroundMethodInfluentialSingle-trial event-related potentials with wavelet denoising
Quiroga, R. Q., & Garcia, H. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00365-6 · Cited by 384
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362 · cited 1×
“As comparative data on P300-BCI visual paradigms are limited; the panel advises further systematic comparisons of CB, SC and RC, and other novel paradigms (Treder and Blankertz 2010) be conducted in the future.”
BackgroundLinear and nonlinear methods for brain-computer interfaces
Muller, K.-R., Anderson, C. W., & Birch, G. E. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814484 · Cited by 360 · cited 1×
“This arrangement is probably due to the preference for simplicity and the belief that linear classification would be sufficient after a decent feature extraction process (Muller et al 2003).”
BackgroundBostanov, V. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826702 · Cited by 346
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
An auditory oddball (P300) spelling system for brain‐computer interfaces
Furdea, A., Halder, S., Krusienski, D. J., Bross, D., Nijboer, F., Birbaumer, N., & Kübler, A. (2009) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00783.x · Cited by 326 · cited 1×
“Recent work by Furdea and colleagues (Furdea et al 2009) demonstrated the feasibility of BCI communication based on the auditory evoked responses user performance was relatively low when compared to visual P300-BCIs.”
BackgroundPiccione, F., Giorgi, F., Tonin, P., Priftis, K., Giove, S., Silvoni, S., Palmas, G., & Beverina, F. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.024 · Cited by 325 · cited 1×
“…have been dominated by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al…”
ResultKübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303 · cited 2×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundA tactile P300 brain-computer interface
Brouwer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00019 · Cited by 278 · cited 1×
“Another attempt to develop a P300-BCI that is independent of vision used a tactile paradigm that has two to six vibratactile stimuli around the waist of subjects (Brouwer and van Erp 2010).”
BackgroundA New Auditory Multi-Class Brain-Computer Interface Paradigm: Spatial Hearing as an Informative Cue
Schreuder, M., Blankertz, B., & Tangermann, M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009813 · Cited by 276 · cited 1×
“In another study, a multi-class auditory P300-BCI based on spatially distributed auditory cues was presented (Schreuder et al 2010).”
BackgroundDien, J., Spencer, K. M., & Donchin, E. (2003) · Cognitive Brain Research · doi:10.1016/s0926-6410(03)00188-5 · Cited by 262 · cited 1×
“These includes methods based on orthogonal linear transformation (Dien et al 2003), blind source separation (Xu et al 2004, Li et al 2009a, Li et al 2009b), wavelet transform (Quian Quiroga and Garcia 2003, Bostanov and Kotchoubey 2006) and other advanced techniques (Rivet et al 2009).”
MethodXu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258 · cited 1×
“These includes methods based on orthogonal linear transformation (Dien et al 2003), blind source separation (Xu et al 2004, Li et al 2009a, Li et al 2009b), wavelet transform (Quian Quiroga and Garcia 2003, Bostanov and Kotchoubey 2006) and other advanced techniques (Rivet et al 2009).”
MethodSingle Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes
Popescu, F., Fazli, S., Badower, Y., Blankertz, B., & Müller, K.-R. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000637 · Cited by 202 · cited 1×
“The development of more user-friendly dry electrodes (Taheri et al 1994, Fonseca et al 2007, Popescu et al 2007, Gargiulo et al 2010) offers a more convenient way for recording brain signals and may enhance the usability of the P300-BCI system, as long as signal quality is comparable (Searle and…”
BackgroundAutomatic removal of the eye blink artifact from EEG using an ICA-based template matching approach
Li, Y., Ma, Z., Lu, W., & Li, Y. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/008 · Cited by 197 · cited 1×
“Different methods have been proposed to remove common sources of artifacts in raw EEG signals such as eye movement (Mennes et al 2010), eye blink (Li et al 2006), muscle contraction (Gao et al 2010) and body movement (Gwin et al 2010).”
MethodA dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 176
A regularized discriminative framework for EEG analysis with application to brain–computer interface
Tomioka, R., & Müller, K.-R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.045 · Cited by 167 · cited 2×
“To achieve high classification accuracy with high dimensional spatiotemporal features, regularization techniques for classifier have been proposed (Blankertz et al (at press) , Farquhar 2009, Tomioka and Muller 2010) to avoid the degradation of performance due to small sample-to-feature ratios.”
BackgroundMethodHigh performance p300 speller for brain-computer interface
Guan, C., Thulasidas, M., & Wu, J. (2005) · IEEE International Workshop on Biomedical Circuits and Systems, 2004. · doi:10.1109/biocas.2004.1454155 · Cited by 165 · cited 1×
“The SC paradigm elicits a larger P300 (Guan et al 2004), but accuracy and speed of communication are reported to be lower than that of RC (Guger et al 2009).”
BackgroundA new EEG recording system for passive dry electrodes
Gargiulo, G., Calvo, R. A., Bifulco, P., Cesarelli, M., Jin, C., Mohamed, A., & van Schaik, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.12.025 · Cited by 165 · cited 1×
“The development of more user-friendly dry electrodes (Taheri et al 1994, Fonseca et al 2007, Popescu et al 2007, Gargiulo et al 2010) offers a more convenient way for recording brain signals and may enhance the usability of the P300-BCI system, as long as signal quality is comparable (Searle and…”
BackgroundSellers, E. W., Kubler, A., & Donchin, E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875580 · Cited by 160 · cited 2×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundA Novel Dry Active Electrode for EEG Recording
Fonseca, C., Cunha, J. P. S., Martins, R. E., Ferreira, V. M., de Sa, J. P. M., Barbosa, M. A., & Martins da Silva, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.884649 · Cited by 151 · cited 1×
“The development of more user-friendly dry electrodes (Taheri et al 1994, Fonseca et al 2007, Popescu et al 2007, Gargiulo et al 2010) offers a more convenient way for recording brain signals and may enhance the usability of the P300-BCI system, as long as signal quality is comparable (Searle and…”
BackgroundThe P300-based brain–computer interface (BCI): Effects of stimulus rate
McFarland, D. J., Sarnacki, W. A., Townsend, G., Vaughan, T. M., & Wolpaw, J. R. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.029 · Cited by 147
Gao, J., Zheng, C., & Wang, P. (2010) · Clinical EEG and Neuroscience · doi:10.1177/155005941004100111 · Cited by 126 · cited 1×
“Different methods have been proposed to remove common sources of artifacts in raw EEG signals such as eye movement (Mennes et al 2010), eye blink (Li et al 2006), muscle contraction (Gao et al 2010) and body movement (Gwin et al 2010).”
MethodValidation of ICA as a tool to remove eye movement artifacts from EEG/ERP
Mennes, M., Wouters, H., Vanrumste, B., Lagae, L., & Stiers, P. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01015.x · Cited by 116 · cited 1×
“Different methods have been proposed to remove common sources of artifacts in raw EEG signals such as eye movement (Mennes et al 2010), eye blink (Li et al 2006), muscle contraction (Gao et al 2010) and body movement (Gwin et al 2010).”
MethodSilvoni, S. (2009) · Frontiers in Neuroscience · doi:10.3389/neuro.20.001.2009 · Cited by 83 · cited 1×
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundP300 Chinese input system based on Bayesian LDA
Jin, J., Allison, B. Z., Brunner, C., Wang, B., Wang, X., Zhang, J., Neuper, C., & Pfurtscheller, G. (2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.003 · Cited by 66 · cited 2×
“However, languages with a logographic writing system, such as Chinese, pose significant challenges to P300-BCI systems since only a handful of the thousands of distinct logograms in the writing system can be presented to the user at any moment.”
BackgroundDevelopment of ophthalmoplegia in amyotrophic lateral sclerosis during long-term use of respirators
Mizutani, T., Aki, M., SHIOZAWA, R., Unakami, M., Nozawa, T., Yajima, K., Tanabe, H., & Hara, M. (1990) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(90)90165-j · Cited by 65 · cited 1×
“Loss of ocular motor function in late-stage ALS and vent-dependent patients (Pinto and de Carvalho 2008, Mizutani et al 1990) suggests a possible link between impaired vision and below chance level of classification in these subjects.”
BackgroundSingle trial independent component analysis for P300 BCI system
Li, K., Sankar, R. T., Arbel, Y., & Donchin, E. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333745 · Cited by 57 · cited 1×
“These includes methods based on orthogonal linear transformation (Dien et al 2003), blind source separation (Xu et al 2004, Li et al 2009a, Li et al 2009b), wavelet transform (Quian Quiroga and Garcia 2003, Bostanov and Kotchoubey 2006) and other advanced techniques (Rivet et al 2009).”
MethodSelf-citationBostanov, V., & Kotchoubey, B. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.08.012 · Cited by 55 · cited 2×
“Numerous studies have attempted to enhance the classification algorithm by linear methods (Bostanov 2004, Krusienski et al 2006), nonlinear methods (Krusienski et al 2006, Kaper et al 2004), neural network (Cecotti and Graser (at press)), and a combination of classifiers (Rakotomamonjy and Guigue…”
MethodBesio, W. G., Cao, H., & Zhou, P. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916303 · Cited by 52 · cited 1×
“Reported superiority of the tripolar concentric electrode over the standard disc electrode in capturing imagined motor activity (Besio et al 2008) and source separation (Cao et al 2009) calls for the examination of its performance in the P300 and other ERP-based BCI systems.”
BackgroundA linear feature space for simultaneous learning of spatio-spectral filters in BCI
Farquhar, J. D. R. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.06.035 · Cited by 38 · cited 4×
“To achieve high classification accuracy with high dimensional spatiotemporal features, regularization techniques for classifier have been proposed (Blankertz et al (at press) , Farquhar 2009, Tomioka and Muller 2010) to avoid the degradation of performance due to small sample-to-feature ratios.”
BackgroundMethodInfluentialSingle-trial P300 estimation with a spatiotemporal filtering method
Li, R., Keil, A., & Príncipe, J. C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.10.035 · Cited by 24
A novel brain-computer interface using a multi-touch surface
Yuksel, B. F., Donnerer, M., Tompkin, J., & Steed, A. J. (2010) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753452 · Cited by 23
Self-citationA P300-based brain—computer interface
Karlovskii, D. V., Konyshev, V. A., & Selishchev, S. V. (2007) · Biomedical Engineering · doi:10.1007/s10527-007-0007-4 · Cited by 22
An Assistive Communication Brain-Computer Interface for Chinese Text Input
Minett, J. W., Peng, G., Zhou, L., Zheng, H., & Wang, W. Y. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5515559 · Cited by 14 · cited 1×
“While some progress has been made in developing a P300 speller for Chinese (Jin et al 2010, Minett et al 2010), further development is required to make P300-BCIs accessible to individuals whose language has a logographic writing system.”
BackgroundSelf-citationPlug-and-play brain-computer interface keyboard performance
Thompson, D. E., Baker, J. J., Sarnacki, W. A., & Huggins, J. E. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109325 · Cited by 11 · cited 1×
“In a commercial BCI, such interfaces (e.g. USB) could be built in, but for researchers investigating a particular application, the multi-purpose BCI output device (Thompson et al 2009) can be used to provide plug-and-play switch, USB keyboard, and USB mouse outputs.”
BackgroundSelf-citation
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Käthner, I., Wriessnegger, S. C., Müller-Putz, G. R., Kübler, A., & Halder, S. (2014) · Biological Psychology · doi:10.1016/j.biopsycho.2014.07.014 · Cited by 328
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“…Cincotti, & Schalk, 2011; Gerven et al., 2009; Grosse-Wentrup, Mattia, & Oweiss, 2011; Krusienski et al., 2011; Leuthardt et al., 2009; C. T. Lin, Ko, et al., 2010; Lotte, Congedo, Lécuyer, Lamarche, & Arnaldi, 2007; Mak et al., 2011; Millan et al., 2008; Zander & Kothe, 2011; Zhu et al., 2010).”
A Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
Metadata
- Authors
- Mak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B., Ryan, D., Thompson, D., Bianchi, L., & Erdogmus, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1988655265
- Cited by
- 195
- References
- 57
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.