CoChat

Storage requirements in a 100% renewable electricity system: extreme events and inter-annual variability

Open access
Ruhnau, Oliver, Qvist, Staffan · 2022 · Environmental Research Letters
Cited by 152

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

In the context of 100% renewable electricity systems, prolonged periods with persistently scarce supply from wind and solar resources have received increasing academic and political attention. This article explores how such scarcity periods relate to energy storage requirements. To this end, we contrast results from a time series analysis with those from a system cost optimization model, based on a German 100% renewable case study using 35 years of hourly time series data. While our time series analysis supports previous findings that periods with persistently scarce supply last no longer than two weeks, we find that the maximum energy deficit occurs over a much longer period of nine weeks. This is because multiple scarce periods can closely follow each other. When considering storage losses and charging limitations, the period defining storage requirements extends over as much as 12 weeks. For this longer period, the cost-optimal storage needs to be large enough to supply 36 TWh of electricity, which is about three times larger than the energy deficit of the scarcest two weeks. Most of this storage is provided via hydrogen storage in salt caverns, of which the capacity is even larger due to electricity reconversion losses (55 TWh). Adding other sources of flexibility, for example with bioenergy, the duration of the period that defines storage requirements lengthens to more than one year. When optimizing system costs based on a single year rather than a multi-year time series, we find substantial inter-annual variation in the overall storage requirements, with the average year needing less than half as much storage as calculated for all 35 years together. We conclude that focusing on short-duration extreme events or single years can lead to an underestimation of storage requirements and costs of a 100% renewable system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1748-9326/ac4dc8

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 152

Metadata

Authors
Ruhnau, O., & Qvist, S.
Venue
Environmental Research Letters
Published
2022-03-15
Volume
17
Issue
4
Pages
044018
ISSN
1748-9326 (ISSN-L)
OpenAlex
W3193935921
Cited by
152
References
10
FWCI
7.63
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Storage requirements in a 100% renewable electricity system: extreme events and inter-annual variability. https://app.cochat.ai/papers/10.1088/1748-9326/ac4dc8
The paper
Ruhnau, O., & Qvist, S. (2022). Storage requirements in a 100% renewable electricity system: extreme events and inter-annual variability. Environmental Research Letters. https://doi.org/10.1088/1748-9326/ac4dc8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.