Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry to monitor the breath of eight patients with type 1 diabetes mellitus during 'insulin clamp' studies in which insulin and glucose were infused into patients to lower blood glucose levels in steps from normal values into the low glucose (hypoglycaemic) range. The concentration of acetone in breath and the blood sugar concentration of the patients were monitored at each blood glucose concentration. The blood glucose level at the start of the study was typically about 6 mM L(-1), whereas the breath acetone concentration at this blood glucose level was unexpectedly variable, ranging from 1 part-per-million to 21 ppm, in contrast to what was previously believed, i.e. that type 1 diabetes mellitus is characterized by high acetone levels. In all eight patients, the breath acetone declined linearly with blood glucose concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801 · cited 6×
“SIFT-MS has been described in detail previously (Smith and Španěl 1996, 2005, Španěl and Smith 1996, Amann and Smith 2005) so only a brief summary is given here.”
InfluentialDeng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590 · cited 7×
“The accurate measurement of acetone concentrations in breath (or indeed, the concentration of any breath metabolite) is very difficult (Deng et al., 2004).”
InfluentialTurner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379 · cited 5×
“In this study of 30 healthy volunteers, we found that the average non-fasting level of acetone in breath has a geometric mean of 477 ppb with a multiplicative standard deviation of 1.58, with the values ranging from 148 to 2744 ppb (Turner et al 2006d).”
InfluentialSelf-citationEvans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283
Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring
(2005) · doi:10.1142/5796 · Cited by 247
Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229 · cited 2×
“SIFT-MS has been described in detail previously (Smith and Španěl 1996, 2005, Španěl and Smith 1996, Amann and Smith 2005) so only a brief summary is given here.”
SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones
Španěl, P., Ji, Y., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00166-3 · Cited by 226 · cited 3×
“M at m/z 88 as follows (Španěl et al 1997): NO+ + CH3COCH3 → NO+.CH3COCH3.”
On the mammalian acetone metabolism: from chemistry to clinical implications
Kalapos, M. P. (2003) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(03)00051-5 · Cited by 224 · cited 2×
“Acetoacetate may then be decarboxylated to volatile acetone (with a small contribution to breath acetone also from dehydrogenation of 2-propanol (Kalapos 2003)) so that during ketosis, the breath of patients with type 1 diabetes 1752-7155/09/046004+06$30.00 1 © 2009 IOP Publishing Ltd Printed in…”
BackgroundInfluentialAcetone metabolism during diabetic ketoacidosis
Owen, O. E., Trapp, V. E., Skutches, C. L., Mozzoli, M. A., Hoeldtke, R. D., Boden, G., & Reichard, G. A. (1982) · Diabetes · doi:10.2337/diab.31.3.242 · Cited by 190
Smith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180 · cited 1×
“Parenthetically, the relationship appears to be the opposite of that seen in healthy volunteers, where low blood glucose following fasting yields higher breath acetone concentration (Turner et al 2008, Smith et al 1999).”
BackgroundTurner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Self-citationAnalysis of diabetic patient's breath with conducting polymer sensor array
Yu, J.-B., Byun, H., So, M.-S., & Huh, J.-S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.01.040 · Cited by 146
Turner, C., Španěl, P., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/002 · Cited by 140
Self-citationTurner, C., Parekh, B. K., Walton, C., Španěl, P., Smith, D. C., & Evans, M. L. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3402 · Cited by 135 · cited 3×
“Parenthetically, the relationship appears to be the opposite of that seen in healthy volunteers, where low blood glucose following fasting yields higher breath acetone concentration (Turner et al 2008, Smith et al 1999).”
InfluentialSelf-citationSmith, D. C., & Španěl, P. (1996) · International Reviews in Physical Chemistry · doi:10.1080/01442359609353183 · Cited by 135 · cited 3×
“4 SIFT-MS analysis SIFT-MS has been described in detail previously (Smith and Španěl, 1996; Španěl and Smith, 1996, Smith and Španěl, 2005, Amann and Smith, 2005) so only a brief summary is given here.”
Determination of acetone in breath
Teshima, N., Li, J., Toda, K., & Dasgupta, P. Κ. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.12.018 · Cited by 133 · cited 2×
“Another technique which has shown promise for monitoring breath acetone is use of a light-emitting diodebased photometric method (Teshima et al 2005); however, the upper concentration limit is little more than 1 ppm, which is insufficient for even the range of acetone in healthy volunteers (Turner…”
The concentration distributions of some metabolites in the exhaled breath of young adults
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/2/026001 · Cited by 78 · cited 1×
“Several studies have shown the reproducibility of analysis of acetone from subsequent breaths as to better than 10%, for example Španěl et al 2007.”
Relationship between skin acetone and blood β-hydroxybutyrate concentrations in diabetes
Yamane, N., Tsuda, T., Nose, K., Yamamoto, A., Ishiguro, H., & Kondo, T. (2005) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.09.016 · Cited by 71 · cited 4×
“Our data show that, contrary to some reports, absolute levels of breath acetone in people with type 1 diabetes are not invariably higher than those seen in healthy subjects (Deng et al 2004, Yamane et al 2006, Jones et al 1993).”
InfluentialEvans, M. L., Pernet, A., Lomas, J., Jones, J., & Amiel, S. A. (2000) · Diabetes Care · doi:10.2337/diacare.23.7.893 · Cited by 69 · cited 2×
“Typically, metabolic responses to hypoglycaemia occur within 20 minutes after a glucose threshold is reached (Evans et al. 2000) so the use of 40 minute steps allows sufficient time for equilibration of body glucose levels and for measurements to be made.”
Self-citationJones, A. W., Sagarduy, A., Ericsson, E., & Arnqvist, H. J. (1993) · Journal of Analytical Toxicology · doi:10.1093/jat/17.3.182 · Cited by 58 · cited 2×
“Our data show that, contrary to some reports, absolute levels of breath acetone in people with type 1 diabetes are not invariably higher than those seen in healthy subjects (Deng et al 2004, Yamane et al 2006, Jones et al 1993).”
Španěl, P., Turner, C., Wang, T., Bloor, R. N., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/2/n01 · Cited by 46
Self-citationEvans, M. L., Hopkins, D., Macdonald, I. A., & Amiel, S. A. (2004) · Diabetic Medicine · doi:10.1111/j.1464-5491.2004.01174.x · Cited by 22
Self-citationLaffel (1999) · doi:10.1002/(sici)1520-7560(199911/12)15:6<412::aid-dmrr72>3.0.co;2-8 · cited 1×
“In the healthy (non-diabetic) state, ketone bodies are thought to be a protective response to fasting, increasing as both glucose and thus insulin levels fall and circulating stress hormones such as catecholamines and glucagon rise (Kalapos 2003, Laffel 1999, Turner et al 2008).”
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“The most prominent volatile compounds are isoprene [56–59] and acetone [60–62].”
BackgroundNon-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Li, G., Cheng, Z., Xiang, Q., Yan, L., Wang, X., & Xu, J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.117 · Cited by 422
W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
Sun, S., Wang, M., Chang, X., Jiang, Y., Zhang, D., Wang, D., Zhang, Y., & Lei, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127274 · Cited by 338
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Self-citation
Metadata
- Authors
- Turner, C., Walton, C., Hoashi, S., & Evans, M.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2009-12-01
- Volume
- 3
- Issue
- 4
- Pages
- 046004
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W1991024809
- Cited by
- 183
- References
- 23
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.