Design and fabrication of a scalable liver-lobule-on-a-chip microphysiological platform
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The design and fabrication of a very large-scale liver-lobule (VLSLL)-on-a-chip device, providing a microphysiological niche for hepatocytes, is described. The device consists of an integrated network of liver-lobule-like hexagonal tissue-culture chambers constructed in a hybrid layout with a separate seed-feed network. As a key feature, each chamber contains a central outlet mimicking the central vein of a liver lobule. Separating chamber walls located between the culture area and feed network protects cells from the shear force of the convective flow. Arrays of designated passages convey nutrients to the cells by diffusion-dominated mass transport. We simulated the flow velocity, shear stress and diffusion of glucose molecules inside and outside the culture chambers under a continuous flow rate of 1 μ l min −1 . As proof of concept, human hepatocellular carcinoma cells (HepG2) were cultured for periods of 5 and 14 days and human-induced pluripotent stem cell (hiPSC)-derived hepatocytes for 21 days. Stabilized albumin secretion and urea synthesis were observed in the microfluidic devices and cells maintained morphology and functionality during the culture period. Furthermore, we observed 3D tissue-like structure and bile-canaliculi network formation in the chips. Future applications of the described platform include drug development and toxicity studies, as well as the modeling of patient-specific liver diseases, and integration in multi-organ human-on-a-chip systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebral organoids model human brain development and microcephaly
Lancaster, M. A., Renner, M., Martin, C.-A., Wenzel, D., Bicknell, L. S., Hurles, M. E., Homfray, T., Penninger, J. M., Jackson, A. P., & Knoblich, J. A. (2013) · Nature · doi:10.1038/nature12517 · Cited by 5,372
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734 · cited 2×
“Green fluorescent signals from calcein AMsignifies live cells and red signals fromEthD-1 shows dead cells. et al 2010, Kim et al 2012, Jang et al 2013, Trietsch et al 2013, YoonáNo 2013, Maschmeyer et al 2015) indicates the drive towards novel approaches to reproduce the native niche of human…”
Growing Self-Organizing Mini-Guts from a Single Intestinal Stem Cell: Mechanism and Applications
Sato, T., & Clevers, H. (2013) · Science · doi:10.1126/science.1234852 · Cited by 1,170
Idiosyncratic drug hepatotoxicity
Kaplowitz, N. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1750 · Cited by 1,054
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Wilkening, S., Stahl, F., & Bader, A. (2003) · Drug Metabolism and Disposition · doi:10.1124/dmd.31.8.1035 · Cited by 794
Gerets, H. H. J., Tilmant, K., Gerin, B., Chanteux, H., Depelchin, B. O., Dhalluin, S., & Atienzar, F. A. (2012) · Cell Biology and Toxicology · doi:10.1007/s10565-011-9208-4 · Cited by 698
The use of whole organ decellularization for the generation of a vascularized liver organoid
Baptista, P. M., Siddiqui, M. M., Lozier, G., Rodriguez, S. R., Atala, A., & Soker, S. (2011) · Hepatology · doi:10.1002/hep.24067 · Cited by 681
To Scale or Not to Scale: The Principles of Dose Extrapolation
Sharma, V., & McNeill, J. H. (2009) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2009.00267.x · Cited by 544
Westerink, W. M. A., & Schoonen, W. G. E. J. (2007) · Toxicology in Vitro · doi:10.1016/j.tiv.2007.05.014 · Cited by 544
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Microfluidic system for formation of PC-3 prostate cancer co-culture spheroids
Hsiao, A. Y., Torisawa, Y.-S., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., & Takayama, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.047 · Cited by 323
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Liver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Long‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Hemodynamic flow improves rat hepatocyte morphology, function, and metabolic activity in vitro
Dash, A., Simmers, M. B., Deering, T. G., Berry, D. J., Feaver, R. E., Hastings, N. E., Pruett, T. L., LeCluyse, E. L., Blackman, B. R., & Wamhoff, B. R. (2013) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00331.2012 · Cited by 108
Cited by
Hepatic microcirculation and mechanisms of portal hypertension
Gracia-Sancho, J., Marrone, G., & Fernández-Iglesias, A. (2019) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-018-0097-3 · Cited by 274
Organ‐on‐chip models: Implications in drug discovery and clinical applications
Mittal, R., Woo, F. W., Castro, C. S., Cohen, M. A., Karanxha, J., Mittal, J., Chhibber, T., & Jhaveri, V. M. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.27729 · Cited by 234
“A newer methodology is a very large‐scale, liver lobule‐on‐a‐ chip, which can facilitate coculture for multiorgan chips as it incorporates the liver blood circulation, although challenges remain for modeling bile excretion (Banaeiyan et al., 2017).”
BackgroundMicrofluidic organ-on-a-chip models of human liver tissue
Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.041 · Cited by 204
Lung-on-a-chip: the future of respiratory disease models and pharmacological studies
Shrestha, J., Razavi Bazaz, S., Aboulkheyr Es, H., Yaghobian Azari, D., Thierry, B., Ebrahimi Warkiani, M., & Ghadiri, M. (2020) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2019.1710458 · Cited by 195
Kidney-on-a-chip: untapped opportunities
Ashammakhi, N., Wesseling-Perry, K., Hasan, A., Elkhammas, E., & Zhang, Y. S. (2018) · Kidney International · doi:10.1016/j.kint.2018.06.034 · Cited by 175
Metadata
- Authors
- Banaeiyan, A. A., Theobald, J., Paukštyte, J., Wölfl, S., Adiels, C. B., & Goksör, M.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2017-02-03
- Volume
- 9
- Issue
- 1
- Pages
- 015014
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2583102966
- Cited by
- 149
- References
- 22
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).