The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Microfluidic organ-on-a-chip models of human liver tissue
Open accessAbstract
The liver is the largest internal organ of the body with complex microarchitecture and function that plays critical roles in drug metabolism. Hepatotoxicity and drug-induced liver injury (DILI) caused by various drugs is the main reason for late-stage drug failures. Moreover, liver diseases are among the leading causes of death in the world, with the number of new cases arising each year. Although animal models have been used to understand human drug metabolism and toxicity before clinical trials, tridimensional microphysiological systems, such as liver-on-a-chip (Liver Chip) platforms, could better recapitulate features of human liver physiology and pathophysiology and thus, are often more predictive of human outcome. Liver Chip devices have shown promising results in mimicking in vivo condition by recapitulating the sinusoidal structure of the liver, maintaining high cell viability and cellular phenotypes, and emulating native liver functions. Here, we first review the cellular constituents and physiology of the liver and then critically discuss the state-of-the-art chip-based liver models and their applications in drug screening, disease modeling, and regenerative medicine. We finally address the pending issues of existing platforms and touch upon future directions for developing new, advanced on-chip models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonalcoholic Fatty Liver Disease
Angulo, P. (2002) · New England Journal of Medicine · doi:10.1056/nejmra011775 · Cited by 5,228
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Highly efficient generation of human hepatocyte-like cells from induced pluripotent stem cells
Si-Tayeb, K., Noto, F. K., Nagaoka, M., Li, J., Battle, M. A., Duris, C., North, P. E., Dalton, S., & Duncan, S. A. (2010) · Hepatology · doi:10.1002/hep.23354 · Cited by 1,282
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Direct-write bioprinting of cell-laden methacrylated gelatin hydrogels
Bertassoni, L. E., Cardoso, J. C., Manoharan, V., Cristino, A. L., Bhise, N. S., Araujo, W. A., Zorlutuna, P., Vrana, N. E., Ghaemmaghami, A. M., Dokmeci, M. R., et al. (2014) · Biofabrication · doi:10.1088/1758-5082/6/2/024105 · Cited by 642
A liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Reproducing human and cross-species drug toxicities using a liver-chip
Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aax5516 · Cited by 511
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Cited by
Fabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Domingues, C., Santos, A., Alvarez-Lorenzo, C., Concheiro, A., Jarak, I., Veiga, F., Barbosa, I., Dourado, M., & Figueiras, A. (2022) · ACS Nano · doi:10.1021/acsnano.2c00128 · Cited by 235
Bioinspired Artificial Liver System with hiPSC‐Derived Hepatocytes for Acute Liver Failure Treatment
Wang, J., Ren, H., Liu, Y., Sun, L., Zhang, Z., Zhao, Y., & Shi, X. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101580 · Cited by 49
Critical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
Metadata
- Authors
- Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 116
- Pages
- 67-83
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W3081576244
- Cited by
- 204
- References
- 37
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic organ-on-a-chip models of human liver tissue. https://app.cochat.ai/papers/10.1016/j.actbio.2020.08.041
- The paper
- Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020). Microfluidic organ-on-a-chip models of human liver tissue. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2020.08.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.