Visual evoked potentials determine chronic signal quality in a stent-electrode endovascular neural interface
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces directly communicate between the brain and external devices.An effective trade-off between signal quality and safety required for successful clinical translation has yet to be achieved, and represents a great challenge for engineers, neuroscientists, and clinicians.The Stentrode TM , an endovascular neural interface that allows neural signals to be recorded from within a cortical vessel, has demonstrated feasibility with safety for up to six months in a large animal model.Easily-obtained electrophysiological signals to evaluate the effect of implant duration on recording performance are essential for ongoing evaluation of the device.In this work, we demonstrate that a non-invasive and quick visual stimulation technique can be used to assess chronic signal quality of an endovascular neural interface in awake freely moving animals.Visual stimulation requires little or no training to elicit a large, consistent, and well-characterized response.We report the stability of recording quality with the Stentrode over 30 days using voltage measures of signal-to-noise ratio (18.78±1.92dB, mean±std) and peak-to-peak voltages (56.07±9.56μV) computed on visual evoked responses.Signal amplitude and electrochemical impedance spectroscopy suggest that stabilization of the electrode-tissue interface occurred over the first 20 days.However, during this stabilization period, recording quality was minimally impacted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘What’ and ‘where’ in the human brain
Ungerleider, L. G., & Haxby, J. V. (1994) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(94)90066-3 · Cited by 1,913
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 2×
“Thus, the design of effective BMIs require access and communication across areas of the brain for movement restoration and even more so for higher cognitive functions such as memory, planning, and reasoning (Lebedev & Nicolelis 2006, Pesaran et al 2006).”
BackgroundHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
The critical role of retrieval practice in long-term retention
Roediger, H. L., & Butler, A. C. (2011) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2010.09.003 · Cited by 1,796
Visual field maps in human cortex.
Wandell, B. A., Dumoulin, S. O., & Brewer, A. A. (2007) · Neuron · doi:10.1016/j.neuron.2007.10.012 · Cited by 1,231 · cited 1×
“Moreover, human studies have shown that receptive fields form a retinotopic map; thus, the location of information at a cortical level is as a projection with some level of distortion of the visual field (Wandell et al 2007, Harvey & Dumoulin 2011, Wandell & Winawer 2011).”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 2×
“…to evoke neural responses, a simple technique that has been extensively characterized in healthy and pathological subjects (Halliday et al 1972, Klinstornern & Graham 1999, Tobimatsu & Celesia 2006), across animal species, and paired with different recording modalities (Vialatte et al 2010).”
BackgroundMethodRestoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 1×
“…of localized populations of neurons (Nicolelis et al 2003, Chestek et al 2011, Schwarz et al 2014) and enabling the control of dexterous robotic armmovement in humans © 2018 IOPPublishing Ltd (Collinger et al 2012, Hochberg et al 2012, Bouton et al 2016, Flesher et al 2016, Ajiboye et al 2017).”
BackgroundAjiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · cited 1×
“…of localized populations of neurons (Nicolelis et al 2003, Chestek et al 2011, Schwarz et al 2014) and enabling the control of dexterous robotic armmovement in humans © 2018 IOPPublishing Ltd (Collinger et al 2012, Hochberg et al 2012, Bouton et al 2016, Flesher et al 2016, Ajiboye et al 2017).”
BackgroundChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738 · cited 1×
“…to reduce the tissue response by enhancing biocompatibility (Jorfi et al 2015),matching the stiffness of the implant with the biological medium (Lacour et al 2016, Wang et al 2017), using drug-eluting coatings to prevent the fibrotic tissue reaction (Boehler et al 2017, Sanchez-Rexach et al…”
Background
Cited by
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
Neurophysiological considerations for visual implants
Meikle, S. J., & Wong, Y. T. (2022) · Brain Structure and Function · doi:10.1007/s00429-021-02417-2 · Cited by 15
Self-citationLocal field potential phase modulates neural responses to intracortical electrical stimulation
Allison-Walker, T. J., Ann Hagan, M., Chiang Price, N. S., & Tat Wong, Y. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176186 · Cited by 9
Local field potential phase modulates the evoked response to electrical stimulation in visual cortex
Allison-Walker, T., Hagan, M. A., Meikle, S. J., Price, N. S. C., & Wong, Y. T. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada828 · Cited by 3
“The LFP is an extracellular signal comprising the summed synaptic activity of neurons within a small region of neural tissue in the order of hundreds of microns [19–23].”
Self-citation
Metadata
- Authors
- Gerboni, G., John, S. E., Rind, G. S., Ronayne, S. M., May, C. N., Oxley, T. J., Grayden, D. B., Opie, N. L., & Wong, Y. T.
- Venue
- Biomedical Physics & Engineering Express
- Publisher
- IOP Publishing
- Published
- 2018-08-20
- Volume
- 4
- Issue
- 5
- Pages
- 055018
- ISSN
- 2057-1976 (ISSN-L)
- OpenAlex
- W2887915487
- Cited by
- 14
- References
- 17
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual evoked potentials determine chronic signal quality in a stent-electrode endovascular neural interface. https://app.cochat.ai/papers/10.1088/2057-1976/aad714
- The paper
- Gerboni, G., John, S. E., Rind, G. S., Ronayne, S. M., May, C. N., Oxley, T. J., Grayden, D. B., Opie, N. L., & Wong, Y. T. (2018). Visual evoked potentials determine chronic signal quality in a stent-electrode endovascular neural interface. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/aad714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.