A Polymer Foam Conduit Seeded with Schwann Cells Promotes Guided Peripheral Nerve Regeneration
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Alternatives to autografts have long been sought for use in bridging neural gaps. Many entubulation materials have been studied, although with generally disappointing results in comparison with autografts. The purpose of this study was to design a more effective neural guidance conduit, to introduce Schwann cells into the conduit, and to determine regenerative capability through it in an in vivo model. A novel, fully biodegradable polymer conduit was designed and fabricated for use in peripheral nerve repair, which approximates the macro- and microarchitecture of native peripheral nerves. It comprised a series of longitudinally aligned channels, with diameters ranging from 60 to 550 microns. The lumenal surfaces promoted the adherence of Schwann cells, whose presence is known to play a key role in nerve regeneration. This unique channel architecture increased the surface area available for Schwann cell adherence up to five-fold over that available through a simple hollow conduit. The conduit was composed of a high-molecular-weight copolymer of lactic and glycolic acids (PLGA) (MW 130,000) in an 85:15 monomer ratio. A novel foam-processing technique, employing low-pressure injection molding, was used to create highly porous conduits (approximately 90% pore volume) with continuous longitudinal channels. Using this technique, conduits were constructed containing 1, 5, 16, 45, or more longitudinally aligned channels. Prior to cellular seeding of these conduits, the foams were prewet with 50% ethanol, flushed with physiologic saline, and coated with laminin solution (10 microg/mL). A Schwann cell suspension was dynamically introduced into these processed foams at a concentration of 5 X 10(5) cells/mL, using a simple bioreactor flow loop. In vivo regeneration studies were carried out in which cell-laden five-channel polymer conduits (individual channel ID 500 microm, total conduit OD 2.3 mm) were implanted across a 7-mm gap in the rat sciatic nerve (n = 4), and midgraft axonal regeneration compared with autografts (n = 6). At 6 weeks, axonal regeneration was observed in the midconduit region of all five channels in each experimental animal. The cross-sectional area comprising axons relative to the open conduit cross sectional area (mean 26.3%, SD 10. 1%) compared favorably with autografts (mean 23.8%, SD 3.6%). Our methodology can be used to create polymer foam conduits containing longitudinally aligned channels, to introduce Schwann cells into them, and to implant them into surgically created neural defects. These conduits provide an environment permissive to axonal regeneration. Furthermore, this polymer foam-processing method and unique channeled architecture allows the introduction of neurotrophic factors into the conduit in a controlled fashion. Deposition of different factors into distinct regions within the conduit may be possible to promote more precisely guided neural regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Brockes, J. P., Fields, K. L., & Raff, M. C. (1979) · Brain Research · doi:10.1016/0006-8993(79)90048-9 · Cited by 1,015
Biodegradable polymers as drug delivery systems
(1992) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(92)90663-b · Cited by 779
Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Mackinnon, S. E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199003000-00015 · Cited by 535
Guenard, V, Kleitman, N., Morrissey, T., Bunge, R., & Aebischer, P. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-09-03310.1992 · Cited by 474
Archibald, S. J., Krarup, C., Shefner, J., Li, S., & Madison, R. D. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903060410 · Cited by 374
Controlled release of bioactive agents from lactide/glycolide polymers
Lewis, D. H. (1990) · Drugs and the pharmaceutical sciences · Cited by 370
The immunosuppressant FK506 increases the rate of axonal regeneration in rat sciatic nerve
Gold, B., Katoh, K., & Storm-Dickerson, T. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-11-07509.1995 · Cited by 337
Chronic Nerve Compression—an Experimental Model in the Rat
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1984) · Annals of Plastic Surgery · doi:10.1097/00000637-198408000-00004 · Cited by 307
Self-citationComplications from silicon‐polymer intubulation of nerves
Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S. (1989) · Microsurgery · doi:10.1002/micr.1920100213 · Cited by 298
Cited by
Electrospinning and Electrospun Nanofibers: Methods, Materials, and Applications
Xue, J., Wu, T., Dai, Y., & Xia, Y. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00593 · Cited by 5,015
Biomimetic materials for tissue engineering
Shin, H., Jo, S., & Mikos, A. G. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00339-9 · Cited by 1,612
Neural Tissue Engineering: Strategies for Repair and Regeneration
Schmidt, C. E., & Leach, J. B. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.011303.120731 · Cited by 1,237
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Taboas, J. M., Maddox, R. D., Krebsbach, P. H., & Hollister, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00276-4 · Cited by 691
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
“sion precipitation particulate leaching [82,83], extrusion [84,85], injection molding [86,87], non-woven or woven mesh rolling”
MethodGu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Daly, W., Yao, L., Zeugolis, D., Windebank, A., & Pandit, A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0438 · Cited by 551
Topography, Cell Response, and Nerve Regeneration
Hoffman-Kim, D., Mitchel, J. A., & Bellamkonda, R. V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105351 · Cited by 516
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Electrospinning of polymer nanofibers for tissue regeneration
Jiang, T., Carbone, E. J., Lo, K. W.-H., & Laurencin, C. T. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.12.001 · Cited by 487
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Biocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Sundback, C. A., Shyu, J. Y., Wang, Y., Faquin, W. C., Langer, R. S., Vacanti, J. P., & Hadlock, T. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.004 · Cited by 443
Self-citationPeripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 415
Fabrication of PLGA scaffolds using soft lithography and microsyringe deposition
Vozzi, G., Flaim, C., Ahluwalia, A., & Bhatia, S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00052-8 · Cited by 373
Pfister, B. J., Gordon, T., Loverde, J. R., Kochar, A. S., Mackinnon, S. E., & Cullen, D. K. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i2.20 · Cited by 358
Toward engineering functional organ modules by additive manufacturing
Marga, F., Jakab, K., Khatiwala, C., Shepherd, B., Dorfman, S., Hubbard, B., Colbert, S., & Gabor, F. (2012) · Biofabrication · doi:10.1088/1758-5082/4/2/022001 · Cited by 348
Biocompatibility evaluation of silk fibroin with peripheral nerve tissues and cells in vitro
Yang, Y., Chen, X., Ding, F., Zhang, P., Liu, J., & Gu, X. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.004 · Cited by 333
Panseri, S., Cunha, C., Lowery, J., Del Carro, U., Taraballi, F., Amadio, S., Vescovi, A., & Gelain, F. (2008) · BMC Biotechnology · doi:10.1186/1472-6750-8-39 · Cited by 321
Bioactive poly(l-lactic acid) conduits seeded with Schwann cells for peripheral nerve regeneration
Evans, G. R. D., Brandt, K., Katz, S., Chauvin, P., Otto, L., Bogle, M., Wang, B., Meszlenyi, R. K., Lu, L., Mikos, A. G., et al. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00190-9 · Cited by 319
Creation of highly aligned electrospun poly-L-lactic acid fibers for nerve regeneration applications
Wang, H. B., Mullins, M. E., Cregg, J. M., Hurtado, A., Oudega, M., Trombley, M. T., & Gilbert, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016001 · Cited by 312
Nerve conduits and growth factor delivery in peripheral nerve repair
Pfister, L. A., Papaloïzos, M., Merkle, H. P., & Gander, B. (2007) · Journal of the Peripheral Nervous System · doi:10.1111/j.1529-8027.2007.00125.x · Cited by 294
3D printed anatomical nerve regeneration pathways
Johnson, B. N., Lancaster, K. Z., Zhen, G., He, J., Gupta, M. K., Kong, Y. L., Engel, E. A., Krick, K. D., Ju, A., Meng, F., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501760 · Cited by 293
Effect of Allogeneic Schwann Cell Transplantation on Peripheral Nerve Regeneration
Mosahebi, A., Fuller, P., Wiberg, M., & Terenghi, G. (2002) · Experimental Neurology · doi:10.1006/exnr.2001.7846 · Cited by 256
Nerve grafting for peripheral nerve injuries with extended defect sizes
Kornfeld, T., Vogt, P. M., & Radtke, C. (2019) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-018-0675-6 · Cited by 237
Gaudin, R., Knipfer, C., Henningsen, A., Smeets, R., Heiland, M., & Hadlock, T. (2016) · BioMed Research International · doi:10.1155/2016/3856262 · Cited by 207
“outcomes in regeneration compared with autografts [144].”
MethodSelf-citationChoi, J.-W., Wicker, R., Lee, S.-H., Choi, K.-H., Ha, C.-S., & Chung, I. (2009) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2009.05.004 · Cited by 200
Yu, X., & Bellamkonda, R. V. (2003) · Tissue Engineering · doi:10.1089/107632703322066606 · Cited by 186
“4,5 However, high concentrations of Schwann cells (60–80 million Schwann cells/mL) are needed for functional efficacy 6 and an unacceptably long time is required to culture sufficient numbers, allowing the injury to worsen.”
Hu, J., Zhu, Q.-T., Liu, X.-L., Xu, Y.-B., & Zhu, J.-K. (2007) · Experimental Neurology · doi:10.1016/j.expneurol.2006.11.018 · Cited by 174
Bini, T. B., Gao, S., Xu, X., Wang, S., Ramakrishna, S., & Leong, K. W. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20050 · Cited by 167
An aligned 3D neuronal-glial co-culture model for peripheral nerve studies
Daud, M. F. B., Pawar, K. C., Claeyssens, F., Ryan, A. J., & Haycock, J. W. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.008 · Cited by 158
“The ability of Schwann cells to enhance neurite length has been reported previously in vivo [38,39] which is consistent with the present study.”
ResultElectrical Stimulation of Schwann Cells Promotes Sustained Increases in Neurite Outgrowth
Koppes, A. N., Nordberg, A. L., Paolillo, G. M., Goodsell, N. M., Darwish, H. A., Zhang, L., & Thompson, D. M. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0012 · Cited by 108
Metadata
- Authors
- Hadlock, T., Sundback, C., Hunter, D., Cheney, M., & Vacanti, J. P.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2000-04
- Volume
- 6
- Issue
- 2
- Pages
- 119-127
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2024643463
- Cited by
- 404
- References
- 22
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.