Effect of Pore Size and Void Fraction on Cellular Adhesion, Proliferation, and Matrix Deposition
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The aim of this study was to determine the influence of two key scaffold design parameters, void fraction (VF) and pore size, on the attachment, growth, and extracellular matrix deposition by several cell types. Disc-shaped, porous, poly(-lactic acid) (L-PLA) scaffolds were manufactured by the TheriForm solid free-form fabrication process to generate scaffolds with two VF (75% and 90%) and four pore size distributions (< 38, 38-63, 63-106, and 106-150 microm). Microcomputed tomography analysis revealed that the average pore size was generally larger than the NaCl used, while VF was at or near the designated percentage. The response of three cell types-canine dermal fibroblasts (DmFb), vascular smooth muscle cells (VSMC), or microvascular epithelial cells (MVEC)-to variations in architecture during a 4-week culture period were assessed using histology, metabolic activity, and extracellular matrix deposition as comparative metrics. DmFb, VSMC, and MVEC showed uniform seeding on scaffolds with 90% VF for each pore size, in contrast to the corresponding 75% VF scaffolds. DmFb showed the least selectivity for pore sizes. VSMC displayed equivalent cell proliferation and matrix deposition for the three largest pore sizes. MVEC formed disconnected webs of tissue with sparse extracellular matrix at 90% VF and >38 to 150 microm; however, when cultured on scaffolds with pores formed with salt particles of <38 microm, MVEC formed a multilayered lining on the scaffolds surface. Culture data from scaffolds with a 75% VF suggests that the structural features were unsuitable for tissue formation. Hence, there were limits of acceptable scaffold architecture (VF, pore size) that modulated in vitro cellular responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Tissue Engineering
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07193-4 · Cited by 1,906
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Yannas, I. V., Lee, E., Orgill, D. P., Skrabut, E. M., & Murphy, G. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.3.933 · Cited by 972
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Three-Dimensional Printing: Rapid Tooling and Prototypes Directly from a CAD Model
Sachs, E., Cima, M., & Cornie, J. (1990) · CIRP Annals · doi:10.1016/s0007-8506(07)61035-x · Cited by 871
Engelberg, I., & Kohn, J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90037-b · Cited by 803
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Taboas, J. M., Maddox, R. D., Krebsbach, P. H., & Hollister, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00276-4 · Cited by 691
Scaffold development using 3D printing with a starch-based polymer
Lam, C. X. F., Mo, X. M., Teoh, S. H., & Hutmacher, D. W. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00012-7 · Cited by 614
A three-dimensional osteochondral composite scaffold for articular cartilage repair
Sherwood, J. K., Riley, S. L., Palazzolo, R., Brown, S. C., Monkhouse, D. C., Coates, M., Griffith, L. G., Landeen, L. K., & Ratcliffe, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00223-5 · Cited by 610
Self-citation
Cited by
Items 101–121 of 121
3D Bioprinting Using a Templated Porous Bioink
Armstrong, J. P. K., Burke, M., Carter, B. M., Davis, S. A., & Perriman, A. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600022 · Cited by 182
Simpson, R. L., Wiria, F. E., Amis, A. A., Chua, C. K., Leong, K. F., Hansen, U. N., Chandrasekaran, M., & Lee, M. W. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30839 · Cited by 181
Cord blood-hematopoietic stem cell expansion in 3D fibrin scaffolds with stromal support
Ventura Ferreira, M. S., Jahnen-Dechent, W., Labude, N., Bovi, M., Hieronymus, T., Zenke, M., Schneider, R. K., & Neurs, S. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.029 · Cited by 177
“The higher the porosity of a material, the greater the cellular growth response [42].”
BackgroundStrategies to Tune Electrospun Scaffold Porosity for Effective Cell Response in Tissue Engineering
Ameer, J. M., PR, A. K., & Kasoju, N. (2019) · Journal of Functional Biomaterials · doi:10.3390/jfb10030030 · Cited by 174
Harris, M., Potgieter, J., Archer, R., & Arif, K. M. (2019) · Materials · doi:10.3390/ma12101664 · Cited by 173
“Medical Scaffolds, Organs and Tissues Poly caprolactone (PCL) [85], Poly(Ethylene Glycol) Terephthalate Poly(Butylene Terephthalate)(PEGT/PBT) [86], Chitosan/hydroxyapatite, Polyurethane [87], Poly l-lactide (L-PLA) [88], Corn starch/dextran/gelatin [89], Polylactic acid/Poly caprolactone [85], Chitosan/Hydroxyapatite…”
Hedberg, E. L., Shih, C. K., Lemoine, J. J., Timmer, M. D., K. Liebschner, M. A., Jansen, J. A., & Mikos, A. G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.012 · Cited by 173
Truong, N. F., Kurt, E., Tahmizyan, N., Lesher-Pérez, S. C., Chen, M., Darling, N. J., Xi, W., & Segura, T. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.02.054 · Cited by 172
Miot, S., Woodfield, T., Daniels, A. U., Suetterlin, R., Peterschmitt, I., Heberer, M., van Blitterswijk, C. A., Riesle, J., & Martin, I. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.048 · Cited by 169
“1B), which in turn could be analyzed to give information on SV percent (vol%) porosity, surface area to volume ratio, pore size and accessible PV using previously described techniques [2,20,26–28].”
BackgroundMethodSilk fibroin–keratin based 3D scaffolds as a dermal substitute for skin tissue engineering
Bhardwaj, N., Sow, W. T., Devi, D., Ng, K. W., Mandal, B. B., & Cho, N.-J. (2015) · Integrative Biology · doi:10.1039/c4ib00208c · Cited by 166
Additive Manufacturing of Biomaterials − The Evolution of Rapid Prototyping
Touri, M., Kabirian, F., Saadati, M., Ramakrishna, S., & Mozafari, M. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201800511 · Cited by 165
Noshadi, I., Walker, B. W., Portillo-Lara, R., Shirzaei Sani, E., Gomes, N., Aziziyan, M. R., & Annabi, N. (2017) · Scientific Reports · doi:10.1038/s41598-017-04280-w · Cited by 162
Zhang, Y., Fan, W., Ma, Z., Wu, C., Fang, W., Liu, G., & Xiao, Y. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.030 · Cited by 161
Moore, M. J., Jabbari, E., Ritman, E. L., Lu, L., Currier, B. L., Windebank, A. J., & Yaszemski, M. J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30138 · Cited by 161
3D Bioprinting of Macroporous Materials Based on Entangled Hydrogel Microstrands
Kessel, B., Lee, M., Bonato, A., Tinguely, Y., Tosoratti, E., & Zenobi‐Wong, M. (2020) · Advanced Science · doi:10.1002/advs.202001419 · Cited by 160
Huang, W., Zheng, Q., Sun, W., Xu, H., & Yang, X. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.02.021 · Cited by 159
Kelly, C. N., Miller, A. T., Hollister, S. J., Guldberg, R. E., & Gall, K. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701095 · Cited by 159
Ma, Y., Ji, Y., Zhong, T., Wan, W., Yang, Q., Li, A., Zhang, X., & Lin, M. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00601 · Cited by 158
Effect of pore size and cross-linking of a novel collagen-elastin dermal substitute on wound healing
Boekema, B. K. H. L., Vlig, M., Olde Damink, L., Middelkoop, E., Eummelen, L., Bühren, A. V., & Ulrich, M. M. W. (2014) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-013-5075-2 · Cited by 77
“Fibroblasts were able to cover large pore sizes, whereas endothelial cells were not [7–9].”
BackgroundFreeze-gelled silk fibroin protein scaffolds for potential applications in soft tissue engineering
Bhardwaj, N., Chakraborty, S., & Kundu, S. C. (2011) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2011.04.013 · Cited by 60
Jiang, C., Huang, J., & Hsieh, M. (2011) · Rapid Prototyping Journal · doi:10.1108/13552541111138414 · Cited by 38
(2005) · PubMed · Cited by 21
Metadata
- Authors
- Zeltinger, J., Sherwood, J. K., Graham, D. A., Müeller, R., & Griffith, L. G.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-10
- Volume
- 7
- Issue
- 5
- Pages
- 557-572
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2016811506
- Cited by
- 794
- References
- 37
- FWCI
- 15.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.