Spatiotemporal effects of a controlled-release anti-inflammatory drug on the cellular dynamics of host response
Open accessAbstract
In general, biomaterials induce a non-specific host response when implanted in the body. This reaction has the potential to interfere with the function of the implanted materials. One method for controlling the host response is through local, controlled-release of anti-inflammatory agents. Herein, we investigate the spatial and temporal effects of an anti-inflammatory drug on the cellular dynamics of the innate immune response to subcutaneously implanted poly(lactic-co-glycolic) microparticles. Noninvasive fluorescence imaging was used to investigate the influence of dexamethasone drug loading and release kinetics on the local and systemic inhibition of inflammatory cellular activities. Temporal monitoring of host response showed that inhibition of inflammatory proteases in the early phase was correlated with decreased cellular infiltration in the later phase of the foreign body response. We believe that using controlled-release anti-inflammatory platforms to modulate early cellular dynamics will be useful in reducing the foreign body response to implanted biomaterials and medical devices.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Alginate microspheres placed in the intraperitoneal space of non-human primates or immunocompetent rodents cause foreign body reactions and fibrosis.
“When implanted into the intraperitoneal space of non-human primates or immunocompetent rodents, alginate microspheres elicit foreign body reactions and fibrosis29, 30.”
From Size- and shape-dependent foreign body immune response to materials implanted in rodents and non-human primates (2015) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Current protocols in molecular biology
Sargent, T. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90147-9 · Cited by 7,298 · see citing works
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1× · see citing works
“In the later phase of days 17 and 27, wound healing might have already resolved [9] with the formation of strong fibrotic capsules containing the particles; and thus the samples became more resilient during histology processing.”
Robbins and Cotran Pathologic Basis of Disease
Hoda, S. A., & Hoda, R. S. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa163 · Cited by 3,369 · see citing works
Antiinflammatory Action of Glucocorticoids — New Mechanisms for Old Drugs
Rhen, T., & Cidlowski, J. A. (2005) · New England Journal of Medicine · doi:10.1056/nejmra050541 · Cited by 3,149 · see citing works
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · see citing works
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617 · see citing works
Jain, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00115-0 · Cited by 2,214 · see citing works
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C., Mahmood, U., & Bogdanov, A. A., Jr. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591 · see citing works
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · see citing works
Neutrophil granules and secretory vesicles in inflammation
Faurschou, M., & Borregaard, N. (2003) · Microbes and Infection · doi:10.1016/j.micinf.2003.09.008 · Cited by 1,162 · see citing works
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., et al. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 853 · see citing works
Anti-inflammatory drugs and their mechanism of action
Vane, J. R., & Botting, R. M. (1998) · Inflammation Research · doi:10.1007/s000110050284 · Cited by 801 · see citing works
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560 · see citing works
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491 · see citing works
Principles of pharmacology : the pathophysiologic basis of drug therapy
Golan, D. E., & Tashjian, A. H. (2012) · Cited by 473 · see citing works
Therapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358 · see citing works
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351 · see citing works
In vivo imaging of proteolytic enzyme activity using a novel molecular reporter.
Tung, C., Mahmood, U., Bredow, S., et al. (2000) · PubMed · Cited by 350 · see citing works
Zhong, Y., & Bellamkonda, R. V. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.024 · Cited by 321 · see citing works
Proteomic Analysis of Human Neutrophil Granules
Lominadze, G., Powell, D. W., Luerman, G., Link, A. J., Ward, R. A., & McLeish, K. R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500143-mcp200 · Cited by 317 · see citing works
Methods to Assess in Vitro Drug Release from Injectable Polymeric Particulate Systems
D’Souza, S. S., & DeLuca, P. P. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-9397-8 · Cited by 293 · see citing works
Evaluation of in vivo–in vitro release of dexamethasone from PLGA microspheres
Zolnik, B. S., & Burgess, D. J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.004 · Cited by 287 · see citing works
de Vos, P., de Haan, B. J., Wolters, G. H. J., STRUBBE, J. H., & Schilfgaarde, R. V. (1997) · Diabetologia · doi:10.1007/s001250050673 · Cited by 279 · see citing works
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268 · see citing works
Tuckermann, J. P., Kleiman, A., Moriggl, R., Spanbroek, R., Neumann, A., Illing, A., Clausen, B. E., Stride, B., Förster, I., Habenicht, A. J. R., et al. (2007) · Journal of Clinical Investigation · doi:10.1172/jci28034 · Cited by 252 · see citing works
Immune response in biocompatibility
Remes, A., & Williams, D. F. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90010-l · Cited by 251 · see citing works
Long-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Self-citationTuckermann, J. P., Kleiman, A., Moriggl, R., Spanbroek, R., Neumann, A., Illing, A., Clausen, B. E., Stride, B. D., Förster, I., Habenicht, A. J. R., et al. (2007) · HAL · Cited by 224 · see citing works
Biocompatibility Issues of Implantable Drug Delivery Systems
Park, H., & Park, K. (1996) · Pharmaceutical Research · doi:10.1023/a:1016012520276 · Cited by 210 · see citing works
Hickey, T., Kreutzer, D. L., Burgess, D. J., & Moussy, F. G. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10016 · Cited by 187 · see citing works
Galeska, I., Kim, T.-K., Patil, S. D., Bhardwaj, U., Chatttopadhyay, D., Papadimitrakopoulos, F., & Burgess, D. J. (2005) · The AAPS Journal · doi:10.1208/aapsj070122 · Cited by 170 · see citing works
Causes of limited survival of microencapsulated pancreatic islet grafts
de Groot, M., Schuurs, T. A., & van Schilfgaarde, R. (2004) · Journal of Surgical Research · doi:10.1016/j.jss.2004.02.018 · Cited by 170 · see citing works
Patil, S. D., Papadimitrakopoulos, F., & Burgess, D. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.887 · Cited by 135 · see citing works
Schilfgaarde, R. V., & de Vos, P. (1999) · Journal of Molecular Medicine · doi:10.1007/s001090050336 · Cited by 133 · see citing works
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99 · see citing works
Human macrophage-mediated biodegradation of polyurethanes: assessment of candidate enzyme activities
Labow, R. S., Meek, E., Matheson, L. A., & Santerre, J. P. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00137-0 · Cited by 94 · see citing works
Silicone breast implants: The role of immune system on capsular contracture formation
Granchi, D., Cavedagna, D., Ciapetti, G., et al. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290209 · Cited by 88 · see citing works
k Opioids as potential treatments for stimulant dependence
Prisinzano, T. E., Tidgewell, K. J., & Harding, W. W. (2005) · The AAPS Journal · doi:10.1208/aapsj070361 · Cited by 79 · see citing works
Rapid Biocompatibility Analysis of Materials via In Vivo Fluorescence Imaging of Mouse Models
Bratlie, K. M., Dang, T. T., Lyle, S. R., Nahrendorf, M., Weissleder, R., Langer, R., & Anderson, D. G. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010032 · Cited by 64 · see citing works
Self-citationNeutrophil-mediated degradation of segmented polyurethanes
Labow, R. S. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91096-h · Cited by 63 · see citing works
Image analysis in the evaluation of biomaterials
Hunt, J. A., Vince, D. G., & Williams, D. F. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90091-c · Cited by 44 · see citing works
Winet, H., & Bao, J. Y. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4 · Cited by 44 · see citing works
A dexamethasone‐loaded PLGA microspheres/collagen scaffold composite for implantable glucose sensors
Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32512 · Cited by 44 · see citing works
Assessment of Chronically Implanted Subcutaneous Glucose Sensors in Dogs
Ward, W. K., & Troupe, J. E. (1999) · ASAIO Journal · doi:10.1097/00002480-199911000-00009 · Cited by 43 · see citing works
Biocompatibility of Electrochemical Glucose Sensors Implanted in the Subcutis of Pigs
Kvist, P. H., Iburg, T. M., Bielecki, M., Gerstenberg, M., Buch‐Rasmussen, T., Hasselager, E., & Jensen, H. E. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.463 · Cited by 38 · see citing works
Applications of Laser Scanning Cytometry in Immunohistochemistry and Routine Histopathology
Peterson, R. A., Krull, D., & Butler, L. (2008) · Toxicologic Pathology · doi:10.1177/0192623307312704 · Cited by 29 · see citing works
Quantifying the soft tissue response to implanted materials
Hunt, J. A., & Williams, D. F. (1995) · Biomaterials · doi:10.1016/0142-9612(95)92113-k · Cited by 28 · see citing works
Singarayar, S., Kistler, P. M., WINTER, C. D., & Mond, H. G. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.40055.x · Cited by 21 · see citing works
Implantable glucose sensor: progress and problems
Moussy, F. G. (2003) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2002.1037097 · Cited by 19 · see citing works
Erfle, D. J., Santerre, J. P., & Labow, R. S. (1997) · Cardiovascular Pathology · doi:10.1016/s1054-8807(97)00031-8 · Cited by 18 · see citing works
Hunt, J. A., & Williams, D. F. (1992) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00713443 · Cited by 15 · see citing works
A hook-traction technique for norplant removal
WARD, C., MATTHEWPETERSON, C., & Hatasaka, H. H. (1995) · Obstetrics and Gynecology · doi:10.1016/0029-7844(95)00295-3 · Cited by 14 · see citing works
Implants for site‐specific drug delivery
Labhasetwar, V. D., & Levy, R. J. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020309 · Cited by 9 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [15]Sharkawy AA Klitzman B Truskey GA Reichert WM Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties J Biomed Mater Res A 1998 40 4 586 97 9599035
Cited by
Sorted by citations
Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897 · see citing works
Self-citationBiocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Farah, S., Doloff, J. C., Müller, P., Sadraei, A., Han, H. J., Olafson, K., Vyas, K., Tam, H. H., Hollister-Lock, J., Kowalski, P. S., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0377-5 · Cited by 181 · see citing works
Self-citationAlagpulinsa, D. A., Cao, J. J. L., Driscoll, R. K., Sîrbulescu, R. F., Penson, M. F. E., Sremac, M., Engquist, E. N., Brauns, T. A., Markmann, J. F., Melton, D. A., et al. (2019) · American Journal of Transplantation · doi:10.1111/ajt.15308 · Cited by 130 · see citing works
Dang, T. T., Thai, A. V., Cohen, J., Slosberg, J. E., Siniakowicz, K., Doloff, J. C., Ma, M., Hollister-Lock, J., Tang, K. M., Gu, Z., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.016 · Cited by 125 · see citing works
Self-citation
- Authors
- Dang, T. T., Bratlie, K. M., Bogatyrev, S. R., Chen, X. Y., Langer, R., & Anderson, D. G.
- Affiliations
- Massachusetts Institute of Technology (US)
- Boston Children's Hospital (US)
- Corresponding author
- Anderson, Daniel G.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 32
- Issue
- 19
- Pages
- 4464-4470
- ISSN
- 0142-9612 (ISSN-L)
- PMC
- PMC5279724
- OpenAlex
- W1972999454
- Cited by
- 38
- References
- 53
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 1 · 2022: 2 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 4 · 2015: 6 · 2014: 2 · 2013: 4 · 2012: 4
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (1f32eb011580-01)
- National Institute of Biomedical Imaging and Bioengineering (F32 EB011580-01, F32 EB011580)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- controlled drug delivery, anti-inflammatory agents, dexamethasone, foreign body reaction, innate immune response, cell infiltration, fluorescence imaging, drug release kinetics
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Anti-Inflammatory Agents, Biocompatible Materials, Delayed-Action Preparations, Dexamethasone, Drug Carriers, Foreign-Body Reaction, Inflammation, Male, Materials Testing, Polyglycolic Acid, Lactic Acid, Prostheses and Implants, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review