A dexamethasone‐loaded PLGA microspheres/collagen scaffold composite for implantable glucose sensors
Abstract
We have developed a new dexamethasone (Dex)‐loaded poly(lactic‐co‐glycolic acid) microspheres/porous collagen scaffold composite for implantable glucose sensors. The scaffolds were fabricated around the sensing element of the sensors and crosslinked using nordihydroguaiaretic acid (NDGA). The microspheres containing Dex were incorporated into the NDGA‐crosslinked collagen scaffold by dipping in microsphere suspension in either water or Pluronic. The loading efficiencies of Dex in the microspheres and the scaffold were determined using high performance liquid chromatography. The microspheres/scaffold composite fabricated using microspheres in the hydrogel solution had a better loading efficiency than when microspheres were in water suspension. The composite fabricated using the hydrogel also showed a slower and more sustained drug release than the standard microspheres in vitro during a 4 week study and did not significantly affect the function of the sensors in vitro. The sensors with the composite that were still functional retained above 50% of their original sensitivity at 2 weeks. Histology showed that the inflammatory response to the Dex‐loaded composite was much lower than for the control scaffold at 2 and 4 weeks after implantation. The Dex‐loaded composite system might be useful to reduce inflammation to implanted glucose sensors and therefore extend their function and lifetime. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dexamethasone-releasing glucose biosensors retained more than 50% of their original sensitivity 2 weeks after implantation, while control membranes dropped to 15-42% of original levels.
“DX-releasing glucose biosensors retained >50% of their original sensitivity 2 weeks after implantation, the sensitivity of control membranes dropped to 15–42% of their original levels.187”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [187]
Cites
Polymeric system for dual growth factor delivery
Richardson, T. P., Peters, M. C., Ennett, A. B., & Mooney, D. J. (2001) · Nature Biotechnology · doi:10.1038/nbt1101-1029 · Cited by 1,753 · see citing works
Encyclopedia of pharmaceutical technology
(2003) · Choice Reviews Online · doi:10.5860/choice.40-6157 · Cited by 1,741 · see citing works
Wanka, G., Hoffmann, H., & Ulbricht, W. (1994) · Macromolecules · doi:10.1021/ma00093a016 · Cited by 1,506 · see citing works
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 662 · see citing works
Kim, D., & Martin, D. C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.021 · Cited by 432 · see citing works
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351 · see citing works
Self-citationLincoff, A. M., Furst, J., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282 · see citing works
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268 · see citing works
Self-citationEncapsulation of dexamethasone into biodegradable polymeric nanoparticles
Gómez-Gaete, C., Tsapis, N., Besnard, M., Bochot, A., & Fattal, E. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.11.028 · Cited by 260 · see citing works
Kissinger, P. T. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.004 · Cited by 233 · see citing works
Yoon, J. J., Kim, J. H., & Park, T. G. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00024-3 · Cited by 173 · see citing works
Wright, C. M. (1987) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(87)70041-x · Cited by 164 · see citing works
Sanders, L. M., Kell, B. A., McRae, G. I., & Whitehead, G. (1986) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600750407 · Cited by 150 · see citing works
Wu, Y., SHAW, S., Lin, H., LEE, T., & YANG, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.002 · Cited by 143 · see citing works
Patil, S. D., Papadimitrakopoulos, F., & Burgess, D. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.887 · Cited by 135 · see citing works
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Bourke, S. L., Al-Khalili, M., Briggs, T., et al. (2003) · AAPS PharmSci · doi:10.1208/ps050433 · Cited by 127 · see citing works
Moatti-Sirat, D., Capron, F., Poitout, V., Reach, G., Bindra, D. S., Zhang, Y., Wilson, G. S., & Th�venot, D. R. (1992) · Diabetologia · doi:10.1007/bf00400921 · Cited by 123 · see citing works
Oh, S. H., Kim, J. K., Song, K. S., et al. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30239 · Cited by 115 · see citing works
Norton, L. W., Tegnell, E., Toporek, S. S., & Reichert, W. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.069 · Cited by 104 · see citing works
Cahn, R. W., Haasen, P., Kramer, E. J., et al. (1991) · Medical Entomology and Zoology · Cited by 102 · see citing works
Fu, Y., Shyu, S., Su, F., & Yu, P.-C. (2002) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(01)00205-3 · Cited by 99 · see citing works
Progress Toward the Development of an Implantable Sensor for Glucose
Wilson, G. S., Zhang, Y., Reach, G., Moatti-Sirat, D., Poitout, V., Thévenot, D. R., Lemonnier, F., & Klein, J. C. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1613 · Cited by 98 · see citing works
Steinleitner, A., Lambert, H., Kazensky, C., et al. (1991) · PubMed · Cited by 92 · see citing works
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87 · see citing works
Polymeric Delivery of Proteins and Plasmid DNA for Tissue Engineering and Gene Therapy
Richardson, T. P., Murphy, W. L., & Mooney, D. J. (2001) · Critical Reviews in Eukaryotic Gene Expression · doi:10.1615/critreveukargeneexpr.v11.i1-3.30 · Cited by 74 · see citing works
In vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors
Mercado, R. C., & Moussy, F. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00112-7 · Cited by 73 · see citing works
Self-citationJu, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31756 · Cited by 70 · see citing works
Self-citationHeya, T., Okada, H., Ogawa, Y., & Toguchi, H. (1994) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600830508 · Cited by 60 · see citing works
Reduction of postoperative adhesions in the rat uterine hornmodel with poloxamer 407
Leach, R. E., & Henry, R. L. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90044-8 · Cited by 57 · see citing works
Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo.
Updike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · PubMed · Cited by 57 · see citing works
Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32400 · Cited by 52 · see citing works
Self-citationUpdike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · ASAIO Journal · doi:10.1097/00002480-199404000-00007 · Cited by 52 · see citing works
Coil-type implantable glucose biosensor with excess enzyme loading
Yu, B. (2005) · Frontiers in bioscience · doi:10.2741/1547 · Cited by 42 · see citing works
Self-citationSteinleitner, A., López, G. F., Suarez, M., et al. (1992) · Fertility and Sterility · doi:10.1016/s0015-0282(16)54835-3 · Cited by 32 · see citing works
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20041 · Cited by 26 · see citing works
Koerten, H. K., Onderwater, J., Koerten, E. W., Bernoski, F. P., & Nelissen, R. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010315)54:4 · Cited by 25 · see citing works
Problemstellung, Zielsetzung und Aufbau der Arbeit
Schlömer, T. (1997) · Deutscher Universitätsverlag eBooks · doi:10.1007/978-3-663-08683-3_1 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67 · see citing works
Dang, T. T., Bratlie, K. M., Bogatyrev, S. R., Chen, X. Y., Langer, R., & Anderson, D. G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.048 · Cited by 38 · see citing works
- Authors
- Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F.
- Affiliations
- University of South Florida (US)
- Corresponding author
- Moussy, Francis
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2009-06-17
- Volume
- 93A
- Issue
- 1
- Pages
- 200-210
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2068671192
- Cited by
- 44
- References
- 39
- Citations by year
- 2026: 2 · 2025: 2 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 1 · 2017: 5 · 2016: 3 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 5
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (R01EB001640)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Keywords
- dexamethasone, PLGA microspheres, collagen scaffolds, implantable glucose sensor, sustained drug release, anti-inflammatory coatings, inflammation, poloxamer
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Collagen, Dexamethasone, Glucose, Inflammation, Microscopy, Electron, Scanning, Microspheres, Polyglycolic Acid, Solvents, Biosensing Techniques, Lactic Acid, Implants, Experimental, Rats, Tissue Scaffolds, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review