Abstract
BACKGROUND: The continuous monitoring of glucose allows for tighter control of the glucose concentration and thus may prevent hyper- and hypoglycemia as well as long-term complications of diabetes. While most current systems depend on the transport of fluid to a glucose sensor outside the body, we investigate the possibility of implanting a reagent-based sensor directly into the skin. In this manuscript, the biocompatibility of an electrochemical sensor for continuous glucose monitoring was assessed in vitro and in vivo. METHODS: Cytotoxicity was investigated in vitro using agar diffusion testing. In vivo biocompatibility was assessed by means of histomorphological examination of the surrounding tissue 10 days after sensor implantation in rats. RESULTS: The grade of cytotoxicity of the individual sensor components in vitro was between none and mild based on agar diffusion testing. The complete sensor also showed no cytotoxic effects when coated with the co-polymer MPC (2-methacryloyloxyethyl phosphorylcholine, Lipidure CM 5206, NOF Corp., Tokyo, Japan) and when assessed under working conditions, i.e., when a bias voltage was applied to the sensor. Additionally, the hydrogen peroxide-which is inherently generated by the enzymatic glucose detection process using glucose oxidase (GOD)-is likely to have been sufficiently decomposed under these working conditions. Finally, no toxic leachable substances were found during the cytotoxicity testing of sensors and its extracts in vitro. In the in vivo experiments, the strongest foreign body reaction (FBR) was found near the GOD-electrode using a sensor without MPC coating and without a porous membrane. Covering the sensor with MPC, a porous membrane, or both led to a gradual decrease of the FBR down to the level of the negative control. CONCLUSIONS: The electrochemical, reagent-based sensor with MPC coating and/or a porous membrane is suitable for continuous monitoring of glucose from a biocompatibility standpoint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomedical surface science: Foundations to frontiers
Castner, D. G., & Ratner, B. D. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01587-4 · Cited by 1,329
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Ertefai, S., & Gough, D. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90097-6 · Cited by 52
Cited by
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
“42,43 The surface of the electrode can become covered with cells or other substances, 21 and the sensor can be damaged by the effects of proteolytic enzymes and free radicals.”
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Ward, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 325
Synthesis and Performance of Novel Hydrogels Coatings for Implantable Glucose Sensors
Wang, C., Yu, B., Knudsen, B., Harmon, J., Moussy, F., & Moussy, Y. (2008) · Biomacromolecules · doi:10.1021/bm701102y · Cited by 63
Metadata
- Authors
- Mang, A., Pill, J., Gretz, N., Kränzlin, B., Buck, H., Schoemaker, M., & Petrich, W.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-02
- Volume
- 7
- Issue
- 1
- Pages
- 163-173
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1973344511
- Cited by
- 38
- References
- 4
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.