Biocompatibility of an Electrochemical Sensor for Continuous Glucose Monitoring in Subcutaneous Tissue

Mang, A., Pill, J., Gretz, N., Kränzlin, B., Buck, H., Schoemaker, M., Petrich, W. · 2005 · Diabetes Technology & Therapeutics
Cited by 38

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The continuous monitoring of glucose allows for tighter control of the glucose concentration and thus may prevent hyper- and hypoglycemia as well as long-term complications of diabetes. While most current systems depend on the transport of fluid to a glucose sensor outside the body, we investigate the possibility of implanting a reagent-based sensor directly into the skin. In this manuscript, the biocompatibility of an electrochemical sensor for continuous glucose monitoring was assessed in vitro and in vivo. METHODS: Cytotoxicity was investigated in vitro using agar diffusion testing. In vivo biocompatibility was assessed by means of histomorphological examination of the surrounding tissue 10 days after sensor implantation in rats. RESULTS: The grade of cytotoxicity of the individual sensor components in vitro was between none and mild based on agar diffusion testing. The complete sensor also showed no cytotoxic effects when coated with the co-polymer MPC (2-methacryloyloxyethyl phosphorylcholine, Lipidure CM 5206, NOF Corp., Tokyo, Japan) and when assessed under working conditions, i.e., when a bias voltage was applied to the sensor. Additionally, the hydrogen peroxide-which is inherently generated by the enzymatic glucose detection process using glucose oxidase (GOD)-is likely to have been sufficiently decomposed under these working conditions. Finally, no toxic leachable substances were found during the cytotoxicity testing of sensors and its extracts in vitro. In the in vivo experiments, the strongest foreign body reaction (FBR) was found near the GOD-electrode using a sensor without MPC coating and without a porous membrane. Covering the sensor with MPC, a porous membrane, or both led to a gradual decrease of the FBR down to the level of the negative control. CONCLUSIONS: The electrochemical, reagent-based sensor with MPC coating and/or a porous membrane is suitable for continuous monitoring of glucose from a biocompatibility standpoint.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2005.7.163

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Mang, A., Pill, J., Gretz, N., Kränzlin, B., Buck, H., Schoemaker, M., & Petrich, W.
Venue
Diabetes Technology & Therapeutics
Published
2005-02
Volume
7
Issue
1
Pages
163-173
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1973344511
Cited by
38
References
4
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.