Evaluation of the Accuracy of a Microdialysis-Based Glucose Sensor During Insulin-Induced Hypoglycemia, Its Recovery, and Post-Hypoglycemic Hyperglycemia in Humans
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: These studies were designed to evaluate the accuracy of a microdialysis-based subcutaneous glucose sensor (GlucoDay, A. Menarini Diagnostics, Firenze, Italy) compared with a standard reference method of plasma glucose measurement during insulin-induced hypoglycemia. RESEARCH DESIGN AND METHODS: Nine subjects without diabetes were studied in eu-, hypo-, and hyperglycemia (clamp technique). The GlucoDay was calibrated against one arterialized plasma glucose measurement (Glucose Analyzer, Beckman, Brea, CA), and plasma glucose estimates every 3 min were compared with paired plasma glucose values. RESULTS: Accuracy of glucose estimates was not homogeneously distributed among subjects and depended on stability of the sensor's current signal during spontaneous euglycemia (R +/- -0.68). Linear regression analysis showed a good correlation between the two methods of measurement (R = 0.9), Deming regression showed the inclusion of the unit in the confidence interval of the slope (slope 0.95, 95% confidence interval 0.87-1.02), and the accuracy of the GlucoDay reached 40 +/- 15% (American Diabetes Association criteria). The mean relative difference was 6 +/- 8% in euglycemia, 13 +/- 14% during plasma glucose fall, 5 +/- 22% in the hypoglycemic plateau, and -14 +/- 16% during recovery from hypoglycemia. The Bland-Altman analysis indicated a bias of -1.9 +/- 16.6 mg/dL, whereas the Error Grid Analysis showed 94% of the Gluco- Day measurements in the acceptable zones of the grid. The time to reach the glycemic nadir was longer when measured with the GlucoDay (90 +/- 5 vs. 72.5 +/- 9 min, P < 0.05). However, absolute values of glycemic nadir, time spent in hypoglycemia, and the rate of fall of glycemia and the rate of recovery from the hypoglycemia were not statistically different. CONCLUSIONS: GlucoDay closely monitors changes in plasma glucose before, during, and after hypoglycemia. However, these results can be achieved only if calibration of the GlucoDay is performed under conditions of sensor signal stability. Similar studies have to be performed in subjects with diabetes to validate the GlucoDay system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Corrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 211
Metadata
- Authors
- Rossetti, P., Porcellati, F., Fanelli, C. G., & Bolli, G. B.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2006-06
- Volume
- 8
- Issue
- 3
- Pages
- 326-337
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2035283260
- Cited by
- 23
- References
- 5
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.