CoChat

How to Assess and Compare the Accuracy of Continuous Glucose Monitors?

Wentholt, I.M.E., Hart, A.A.M., Hoekstra, J.B.L., DeVries, J.H. · 2008 · Diabetes Technology & Therapeutics
Cited by 49

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Continuous glucose monitors may be valuable tools for improving glycemic control and avoiding hypoglycemia in patients with diabetes. To this goal, sensor readings must adequately reflect the actual blood glucose, emphasizing the need for solid accuracy assessment methods for continuous glucose sensor readings. Analysis of continuous glucose data is challenging, and despite many efforts there still is no all-embracing method to overcome the obstacles in the assessment of continuous data. In this review we disclose the weaknesses of currently available methods and propose a guideline for sensor accuracy assessment and comparison. For accuracy assessment it is best to first plot the sensor readings against the reference values and draw a line of identity, visualizing the degree of agreement. Thereafter data pairs should be given in a Bland-Altman plot to detect a possible relationship between the difference and the mean. The next step is to calculate the absolute relative difference over all paired readings together and per glucose range. A possible lag time between the measurements of both methods can be detected by combined curve fitting. Finally, sensitivity and positive predictive value for detecting hypoglycemia are important indicators of the sensors' performance. For comparing the accuracy between different glucose sensors it is best to use indirect comparison against blood glucose, rather than direct comparison methods, since none of the current glucose sensors is accurate enough to be considered the reference value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2007.0216

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 49

Metadata

Authors
Wentholt, I. M. E., Hart, A. A. M., Hoekstra, J. B. L., & DeVries, J. H.
Venue
Diabetes Technology & Therapeutics
Published
2008-04
Volume
10
Issue
2
Pages
57-68
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1997874406
Cited by
49
References
9
FWCI
3.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.