The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Meta-Analysis of the Benefits of Self-Monitoring of Blood Glucose on Glycemic Control in Type 2 Diabetes Patients: An Update
Abstract
Background: Our systematic review and meta-analysis of the benefit of self-monitoring of blood glucose (SMBG) in improving glycemic control in type 2 diabetes was published in 2008. With the few studies that have emerged afterward, we undertook subsequent meta-analysis of the available evidence to update the results. Methods: Clinical trials of SMBG were identified through electronic searches (MEDLINE, EMBASE, and The Cochrane Library) up to and including June 2009. Studies were included if they met the following inclusion criteria: (1) randomized controlled trial comparing SMBG versus non-SMBG in type 2 diabetes patients not using insulin and (2) hemoglobin A1c (HbA 1c ) reported as an outcome measure. The efficacy was estimated with the mean difference in the changes of HbA 1c from baseline to final assessment between the SMBG and the non-SMBG groups. Results: SMBG was effective in reducing HbA 1c in non–insulin-treated type 2 diabetes (pooled mean difference, −0.24%; 95% confidence interval, −0.34% to −0.14%; P < 0.00001). Glycemic control significantly improved among the subgroup of patients whose baseline HbA 1c was ≥8%. In contrast, no significant effect of SMBG was detected in patients who had HbA 1c <8%. Conclusions: The available evidence suggests the usefulness of SMBG in improving glycemic control in non–insulin-treated type 2 diabetes as demonstrated by the reduction of HbA 1c levels. In particular, SMBG proved to be useful in the subgroup of patients whose baseline HbA 1c was ≥8%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The effect of SMBG was limited to patients with HbA 1c values $8% (64 mmol/mol).”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [111]
In the citing paper
“Two recent systematic reviews of randomized controlled studies of SMBG in people with type 2 diabetes not treated with insulin reported small but significantly greater decreases in HbA 1c among patients using SMBG than in controls (110,111).”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [111]
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Verhagen, A. P., de Vet, H. C. W., de Bie, R. A., Kessels, A. G. H., Boers, M., Bouter, L. M., & Knipschild, P. G. (1998) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(98)00131-0 · Cited by 2,470
Monnier, L., Mas, E., Ginet, C., Michel, F., Villon, L., Cristol, J.-P., & Colette, C. (2006) · JAMA · doi:10.1001/jama.295.14.1681 · Cited by 2,444
Updated Method Guidelines for Systematic Reviews in the Cochrane Collaboration Back Review Group
van Tulder, M., Furlan, A., Bombardier, C., & Bouter, L. (2003) · Spine · doi:10.1097/01.brs.0000065484.95996.af · Cited by 2,180
Research works printed but not linked: 5
- 10.1089/dia.2008.0001 · DOI
- 10.1111/j.1463-1326.2008.00894.x · DOI · Paper page
- 10.1002/14651858.CD005060.pub2 · DOI · Paper page
- Deeks JJ, , Higgins JPT, , Altman DG. Analysing and presenting results. Higgins JPT, , Green S. Cochrane Handbook for Systematic Reviews of Interventions 426 [updated September 2006] Chichester, UK: John Wiley & Sons, Ltd., 2006; 120–122.
- Fontbonne A, , Billault B, , Acosta M, , Percheron C, , Varenne P, , Besse A, , Eschwege E, , Monnier L, , Slama G, , Passa P. Is glucose self-monitoring beneficial in non-insulin-treated diabetic patients? Results of a randomized comparative trial. Diabetes Metab, 1989; 15:255–260.
Cited by
Sorted by citations
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Schmitt, A., Gahr, A., Hermanns, N., Kulzer, B., Huber, J., & Haak, T. (2013) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-11-138 · Cited by 587
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Vigersky, R. A., Fonda, S. J., Chellappa, M., Walker, M. S., & Ehrhardt, N. M. (2011) · Diabetes Care · doi:10.2337/dc11-1438 · Cited by 312
Ryan, R. E., Santesso, N., Lowe, D., Hill, S., Grimshaw, J. M., Prictor, M., Kaufman, C., Cowie, G., & Taylor, M. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007768.pub3 · Cited by 273
Effects of an Internet Support System to Assist Cancer Patients in Reducing Symptom Distress
Ruland, C. M., Andersen, T., Jeneson, A., Moore, S. M., Grimsbø, G. H., Børøsund, E., & Ellison, M. C. (2012) · Cancer Nursing · doi:10.1097/ncc.0b013e31824d90d4 · Cited by 219
Dubský, M., Jirkovská, A., Bém, R., Fejfarová, V., Skibová, J., Schaper, N. C., & Lipsky, B. A. (2012) · International Wound Journal · doi:10.1111/j.1742-481x.2012.01022.x · Cited by 215
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
Self-citationFarmer, A. J., Perera, R., Ward, A., Heneghan, C., Oke, J., Barnett, A. H., Davidson, M. B., Guerci, B., Coates, V., Schwedes, U., et al. (2012) · BMJ · doi:10.1136/bmj.e486 · Cited by 156
Young, L. A., Buse, J. B., Weaver, M. A., Vu, M. B., Mitchell, C. M., Blakeney, T., Grimm, K., Rees, J., Niblock, F., Donahue, K. E., et al. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.1233 · Cited by 148
Self-Monitoring of Blood Glucose: Practical Aspects
Kirk, J. K., & Stegner, J. E. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400225 · Cited by 123
Kim, K. B., Lee, W.-C., Cho, C.-H., Park, D., Cho, S. J., & Shim, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.081 · Cited by 110
Berard, L., Blumer, I. R., Houlden, R. L., Miller, D. B., & Woo, V. C. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.01.017 · Cited by 98
Klonoff, D. C., Blonde, L., Cembrowski, G. S., Chacra, A. R., Charpentier, G., Colagiuri, S., DAILEY, G. E., Gabbay, R. A., Heinemann, L., Kerr, D. E., et al. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500630 · Cited by 99
Dip Biosensor Based on Localized Surface Plasmon Resonance at the Tip of an Optical Fiber
Sciacca, B., & Monro, T. M. (2014) · Langmuir · doi:10.1021/la403667q · Cited by 96
Mannucci, E., Antenore, A., Giorgino, F., & Scavini, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817719290 · Cited by 90
Czupryniak, L., Barkai, L., Bolgarska, S. V., Bronisz, A., Brož, J., Cypryk, K., Honka, M., Janež, A., Krnić, M., Lalic, N. M., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0302 · Cited by 104
McBain, H. B., Shipley, M. E., & Newman, S. P. (2015) · BMC Health Services Research · doi:10.1186/s12913-015-1221-5 · Cited by 89
Zhu, H., Zhu, Y., & Leung, S.-W. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010524 · Cited by 84
Berard, L. D., Siemens, R., & Woo, V. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.007 · Cited by 69
Consensus Report of the Coalition for Clinical Research—Self-Monitoring of Blood Glucose
Klonoff, D. C., Bergenstal, R., Blonde, L., Boren, S. A., Church, T. S., Gaffaney, J., Jovanovič, L., Kendall, D. M., Kollman, C., Kovatchev, B. P., et al. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200612 · Cited by 74
Machry, R. V., Rados, D. V., Gregório, G. R. D., & Rodrigues, T. C. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.05.037 · Cited by 55
Glycemic Control Rate of T2DM Outpatients in China: A Multi-Center Survey
Zou, D. (2015) · Medical Science Monitor · doi:10.12659/msm.892246 · Cited by 55
Smart biosensors for an efficient point of care (PoC) health management
Qazi, S., & Raza, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820781-9.00004-8 · Cited by 54
Diabetes mellitus type 2 in adults
Dedov, I. I., Shestakova, M. V., Mayorov, A. Y., Шамхалова, М. Ш., Sukhareva, O. Y., Galstyan, G. R., Tokmakova, A. Y., Nikonova, T. V., Surkova, E. V., Кононенко, И. В., et al. (2020) · Diabetes Mellitus · doi:10.14341/dm12507 · Cited by 60
Biosensing Technologies for Medical Applications, Manufacturing, and Regenerative Medicine
Shafiee, A., Ghadiri, E., Kassis, J. N., Zarandi, N. P., & Atala, A. (2018) · Current Stem Cell Reports · doi:10.1007/s40778-018-0123-y · Cited by 51
Melmer, A., & Laimer, M. W. (2016) · Endocrine development · doi:10.1159/000439364 · Cited by 53
Kempf, K., Kruse, J., & Martin, S. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0116 · Cited by 48
Parsons, S. N., Luzio, S. D., Harvey, J. N., Bain, S. C., Cheung, W. Y., Watkins, A., & Owens, D. R. (2019) · Diabetic Medicine · doi:10.1111/dme.13899 · Cited by 39
Plasmonic metal oxides and their biological applications
Hu, Y., Zhang, B., Haque, F., Ren, G., & Ou, J. Z. (2022) · Materials Horizons · doi:10.1039/d2mh00263a · Cited by 41
Insulin Therapy in Type 2 Diabetes Mellitus
Leahy, J. L. (2012) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2012.03.004 · Cited by 41
Jethwani, K., Ling, E., Mohammed, M., Myint-U, K., Pelletier, A. C., & Kvedar, J. C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600611 · Cited by 39
Current development in wearable glucose meters
Chen, Q., Zhao, Y. J., & Liu, Y. (2021) · Chinese Chemical Letters · doi:10.1016/j.cclet.2021.05.043 · Cited by 40
McIntosh, B., Yu, C., Lal, A., Chelak, K., Cameron, C. G., Singh, S. R., & Dahl, M. (2010) · PubMed Central · Cited by 35
Breland, J. Y., McAndrew, L. M., Burns, E. A., Leventhal, E. A., & Leventhal, H. (2013) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721713490079 · Cited by 33
Nkhoma, K. B., Norton, C. S., Sabin, C. A., Winston, A., Merlin, J. S., & Harding, R. (2018) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000001785 · Cited by 32
Zhu, Y., Meng, X., Chen, Y., Li, J., Shao, H., Lu, Y., Pan, L., Xu, Y., & Cheng, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127235 · Cited by 33
Blood Glucose Monitoring in Adults and Children with Diabetes: Update 2021
CHENG, A. Y. Y., Feig, D. S., Ho, J., Siemens, R. L., BAJAJ, H. S., Gilbert, J. D., Houlden, R. L., Kim, J., MacKay, D., Rabi, D. M., et al. (2021) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2021.07.003 · Cited by 36
Polonsky, W., Fisher, L., Schikman, C., Hinnen, D., Parkin, C., Jelsovsky, Z., Amstutz, L., Schweitzer, M., & Wagner, R. (2010) · BMC Family Practice · doi:10.1186/1471-2296-11-37 · Cited by 30
Wang, J., Wang, M., Wang, H., Liu, H., Lu, R., Duan, T., Li, C., Cui, Z., Liu, Y.-Y., Lyu, Y., et al. (2019) · Chinese Medical Journal · doi:10.1097/cm9.0000000000000585 · Cited by 29
Blevins, T. (2013) · Postgraduate Medicine · doi:10.3810/pgm.2013.05.2668 · Cited by 32
Du, Y., Dennis, B., Rhodes, S. L., Sia, M., Ko, J., Jiwani, R., & Wang, J. (2020) · JMIR Diabetes · doi:10.2196/21183 · Cited by 27
Virdi, N. S., Daskiran, M., Nigam, S., Kozma, C. M., & Raja, P. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0047 · Cited by 27
Renskers, L., Dartel, S. A. A. R.-V., Huis, A. M. P., & van Riel, P. L. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-033321 · Cited by 28
Xu, Y., Tan, D. H. Y., & Lee, J. Y. (2019) · International Journal of Clinical Practice · doi:10.1111/ijcp.13357 · Cited by 26
McAndrew, L. M., Napolitano, M. A., POGACH, L. M., Quigley, K. S., Shantz, K. L., Veur, S. S. V., & Foster, G. D. (2012) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721712449434 · Cited by 24
Prevalence and Predictors of Home Use of Glucometers in Diabetic Patients
Farhan, S. A., Shaikh, A. T., Zia, M., Kahara, B. R., Muneer, R., Rehman, M., Mubashir, A., Sadiq, H., Siddiqui, D.-E.-A., Haseeb, S. M., et al. (2017) · Cureus · doi:10.7759/cureus.1330 · Cited by 24
Alyami, M. M., Serlachius, A. S., Mokhtar, I., & Broadbent, E. (2020) · Health Psychology and Behavioral Medicine · doi:10.1080/21642850.2020.1805322 · Cited by 22
Smart tattoo: technology for monitoring blood glucose in the future
Meetoo, D. D., Wong, L., & Ochieng, B. M. N. (2019) · British Journal of Nursing · doi:10.12968/bjon.2019.28.2.110 · Cited by 22
Aakre, K. M., Watine, J., Bunting, P. S., Sandberg, S., & Oosterhuis, W. P. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2012.03659.x · Cited by 21
Zou, Y. L., Zhao, S., Li, G., & Zhang, C. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-022-07864-z · Cited by 22
Gucciardi, E., Fortugno, M., Senchuk, A., Beanlands, H. J., McCay, E. A., & Peel, E. E. (2013) · BMC Endocrine Disorders · doi:10.1186/1472-6823-13-46 · Cited by 20
Tomah, S., Mahmoud, N., Mottalib, A., POBER, D. M., Tasabehji, M. W., Ashrafzadeh, S., & Hamdy, O. (2019) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-000659 · Cited by 21
Mbanya, J. C., Aschner, P. J., Chan, J. C. N., Gagliardino, J. J., & Saji, J. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2016.11.029 · Cited by 19
Wang, H.-C., Chang, F., Tsai, T.-M., Chen, C.-H., & Chen, Y. (2020) · Biomedical Optics Express · doi:10.1364/boe.389638 · Cited by 19
The role of blood glucose monitoring in non-insulin treated type 2 diabetes: What is the evidence?
Benhalima, K., & Mathieu, C. (2012) · Primary care diabetes · doi:10.1016/j.pcd.2012.05.001 · Cited by 18
Hirsch, I. B., Amiel, S. A., Blumer, I. R., Bode, B. W., Edelman, S. V., Seley, J. J., Verderese, C. A., & Kilpatrick, E. S. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0132 · Cited by 18
Shrestha, M., Ng, A., Al-Ghareeb, A. Z., Alenazi, F., & Gray, R. J. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1084-7 · Cited by 17
Shrestha, M., Ng, A., Al-Ghareeb, A. Z., Alenazi, F., & Gray, R. J. (2020) · Systematic Reviews · doi:10.1186/s13643-020-01302-z · Cited by 19
Dong, Q., Huang, J., Liu, S., Yang, L., Li, J., Li, B., Zhao, X., Li, Z., & Wu, L. (2019) · Patient Preference and Adherence · doi:10.2147/ppa.s198908 · Cited by 17
B. Davidson, M. (2010) · Reviews on Recent Clinical Trials · doi:10.2174/157488710792007248 · Cited by 15
Wang, H.-C., Chang, F., Tsai, T.-M., Chen, C.-H., & Chen, Y.-Y. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.2.027002 · Cited by 15
Advancements in glucose biosensors: Innovations for wearable and real-time monitoring
Singh, R., Nema, P., Purohit, A., Vishwakarma, S., Tantuway, S., Namdeo, P., Kumar, A., Soni, V., & Kashaw, S. K. (2025) · Talanta · doi:10.1016/j.talanta.2025.129045 · Cited by 13
Tunis, S. L. (2011) · Applied Health Economics and Health Policy · doi:10.2165/11594270-000000000-00000 · Cited by 13
Hou, Y., Li, W., Qiu, J., & Wang, X. (2014) · International Journal of Nursing Sciences · doi:10.1016/j.ijnss.2014.05.003 · Cited by 13
Use of Blood Glucose Meters Among People With Type 2 Diabetes: Patient Perspectives
Tenderich, A. (2013) · Diabetes Spectrum · doi:10.2337/diaspect.26.2.67 · Cited by 13
Sudchada, P., Khom-ar-wut, C., Eaimsongchram, A., Katemut, S., Kunmaturos, P., & Deoisares, R. (2012) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2012.02.006 · Cited by 12
SENSORS FOR DIABETES: GLUCOSE BIOSENSORS BY USING DIFFERENT NEWER TECHNIQUES: A REVIEW
Pandey, S., & Singh, S. P. (2012) · Cited by 11
Association between self-monitoring of blood glucose and diet among minority patients with diabetes*
McAndrew, L. M., Horowitz, C. R., Lancaster, K. J., Quigley, K. S., POGACH, L. M., Mora, P. A., & Leventhal, H. (2011) · Journal of Diabetes · doi:10.1111/j.1753-0407.2011.00114.x · Cited by 11
Using Self-Monitoring of Blood Glucose in Noninsulin-Treated Type 2 Diabetes
Cypress, M., & Tomky, D. M. (2013) · Diabetes Spectrum · doi:10.2337/diaspect.26.2.102 · Cited by 11
Sim, K. H., & Hwang, M. S. (2013) · The Journal of Korean Academic Society of Nursing Education · doi:10.5977/jkasne.2013.19.2.127 · Cited by 11
Ordoñez, J. S. F., & Pérez-Gualdrón, C. E. (2019) · Revista de la Facultad de Medicina · doi:10.15446/revfacmed.v67n3.69687 · Cited by 11
A Review of Minimally and Non-invasive Glucose Monitoring Techniques, Devices and Sensors
Nooshnab, M., Naghib, S. M., Rahmanifard, R., & Khakpour, E. (2024) · Current Analytical Chemistry · doi:10.2174/0115734110290007240202154817 · Cited by 10
Evidence-based clinical use of insulin premixtures
Tambascia, M., Nery, M., Gross, J., Ermetice, M. N., & de Oliveira, C. P. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-50 · Cited by 13
Arun Kumar, P., Stanley, J., Babu, T. G. S., & Suneesh, P. V. (2018) · Materials Today Proceedings · doi:10.1016/j.matpr.2018.05.098 · Cited by 10
Recent Advances in Biosensing in Tissue Engineering and Regenerative Medicine
Banigo, A. T., Nnadiekwe, C. A., & Beasi, E. M. (2022) · Biomedical engineering · doi:10.5772/intechopen.104922 · Cited by 10
Evolution of blood glucose self-monitoring technology
Суплотова, Л. А., & Alieva, O. O. (2023) · Diabetes Mellitus · doi:10.14341/dm13063 · Cited by 7
Evaluation of the Capillary Blood Glucose Self-monitoring Program
Augusto, M. C., Nitsche, M. J. T., Pàrada, C. M. G. D. L., Zanetti, M. L., & Carvalhães, M. A. D. B. L. (2014) · Revista Latino-Americana de Enfermagem · doi:10.1590/0104-1169.3282.2483 · Cited by 7
How technology has changed diabetes management and what it has failed to achieve
Ratheau, L., Jeandidier, N., Moreau, F., Sigrist, S., & Pinget, M. (2011) · Diabetes & Metabolism · doi:10.1016/s1262-3636(11)70967-3 · Cited by 7
Song, Y. S., Koo, B. K., Kim, S. W., Yi, K. H., Shin, K., & Moon, M. K. (2018) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2018.42.1.28 · Cited by 6
Self-Monitoring of Blood Glucose in Patients with Insulin-Treated Type 2 Diabetes Mellitus
Kim, K. (2018) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2018.42.1.26 · Cited by 6
A time series analysis : exploring the link between human activity and blood glucose fluctuation
Sadowski, E. A. (2010) · Scholars Commons (Wilfrid Laurier University) · Cited by 4
Young, L., Buse, J. B., Weaver, M. A., Vu, M. B., Reese, A., Mitchell, C. M., Blakeney, T., Grimm, K. F., Rees, J. R., & Donahue, K. E. (2017) · BMC Health Services Research · doi:10.1186/s12913-017-2202-7 · Cited by 5
Tai, J. C. J., Wong, L. Z., & Richardson, A. (2021) · Cureus · doi:10.7759/cureus.15597 · Cited by 5
Application of Sensor Networks for Measuring Insulin Levels
Pandurski, M., & Tsvetanov, F. A. (2020) · International Journal of Online and Biomedical Engineering (iJOE) · doi:10.3991/ijoe.v16i14.17185 · Cited by 5
(2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.02.008 · Cited by 5
Self-monitoring of Blood Glucose in Individuals with Type 2 Diabetes Not Using Insulin: Commentary
Woo, V. C., CHENG, A. Y. Y., Hanna, A., & Berard, L. (2010) · Canadian Journal of Diabetes · doi:10.1016/s1499-2671(10)41003-5 · Cited by 5
Sources of variance in bite count
Scisco, J. L. (2012) · TigerPrints (Clemson University) · Cited by 5
Shrestha, M., Ng, A., & Gray, R. J. (2020) · Journal of Clinical Nursing · doi:10.1111/jocn.15250 · Cited by 4
Kolb, H., Martin, S., Lodwig, V., Heinemann, L., Scherbaum, W. A., & Schneider, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300633 · Cited by 4
Lazzaroni, E., Cimino, V., Gandolfi, A., Tinari, C., Bucciarelli, L. G., Morpurgo, P. S., Nasr, M. B., Fiorina, R. M., Pastore, I., Baruffaldi, L., et al. (2026) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaf165 · Cited by 3
Fritzen, K., Basinska, K., Stautner, C., Braun, K. F., Rubio-Almanza, M., Nicolucci, A., Kennon, B., Vergès, B. L., Hosny, Y., & Schnell, O. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819864665 · Cited by 3
Hamshari, S., Hamadneh, S., Ajlone, A. M., Mashni, A. W., & Jubeh, M. A. (2025) · BMC Family Practice · doi:10.1186/s12875-025-02720-5 · Cited by 5
Chen, M., Lin, X., Zhou, R., & Fan, G. (2025) · BMC Public Health · doi:10.1186/s12889-025-22724-1 · Cited by 2
Priorities of self-monitoring of glycemia: an important component of successful diabetes management
Biryukova, E. V., & Викторович, Ш. М. (2024) · Meditsinskiy sovet = Medical Council · doi:10.21518/ms2024-202 · Cited by 2
Francis, K., Younger-Coleman, N., Tulloch-Reid, M. K., Wright-Pascoe, R., Boyne, M. S., Wilks, R., & Ferguson, T. S. (2014) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-014-0222-y · Cited by 2
Self-monitoring of blood glucose in type 2 diabetes
LOWE, J. M. (2010) · Australian Prescriber · doi:10.18773/austprescr.2010.065 · Cited by 2
Metadata
- Authors
- Poolsup, N., Suksomboon, N., & Rattanasookchit, S.
- Affiliations
- Silpakorn University (TH)
- Mahidol University (TH)
- Corresponding author
- Suksomboon, Naeti
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-12
- Volume
- 11
- Issue
- 12
- Pages
- 775-784
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2078427448
- Cited by
- 127
- References
- 35
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 3 · 2020: 10 · 2019: 11 · 2018: 9 · 2017: 7 · 2016: 3 · 2015: 3 · 2014: 7 · 2013: 17 · 2012: 16
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Technology & Therapeutics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- self-monitoring of blood glucose, type 2 diabetes, glycemic control, HbA1c, non-insulin-treated diabetes, baseline HbA1c, diabetes self-management
- MeSH terms
- Blood Glucose, Clinical Trials as Topic, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Blood Glucose Self-Monitoring, Randomized Controlled Trials as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review