CoChat

Accuracy and Precision Evaluation of Seven Self-Monitoring Blood Glucose Systems

Kuo, Chih-Yi, Hsu, Cheng-Teng, Ho, Cheng-Shiao, Su, Ting-En, Wu, Ming-Hsun, Wang, Chau-Jong · 2011 · Diabetes Technology & Therapeutics
Cited by 55

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Self-monitoring blood glucose (SMBG) systems play a critical role in management of diabetes. SMBG systems should at least meet the minimal requirement of the World Health Organization's ISO 15197:2003. For tight glycemic control, a tighter accuracy requirement is needed. METHODS: Seven SMBG systems were evaluated for accuracy and precision: Bionime Rightest(™) GM550 (Bionime Corp., Dali City, Taiwan), Accu-Chek(®) Performa (Roche Diagnostics, Indianapolis, IN), OneTouch(®) Ultra(®)2 (LifeScan Inc., Milpitas, CA), MediSense(®) Optium(™) Xceed (Abbott Diabetes Care Inc., Alameda, CA), Medisafe (TERUMO Corp., Tokyo, Japan), Fora(®) TD4227 (Taidac Technology Corp., Wugu Township, Taiwan), and Ascensia Contour(®) (Bayer HealthCare LLC, Mishawaka, IN). The 107 participants (44 men and 63 women) were between 23 and 91 years old. The analytical results of seven SMBG systems were compared with those of plasma analyzed with the hexokinase method (Olympus AU640, Olympus America Inc., Center Valley, PA). RESULTS: The imprecision of the seven blood glucose meters ranged from 1.1% to 4.7%. Three of the seven blood glucose meters (42.9%) fulfilled the minimum accuracy criteria of ISO 15197:2003. The mean absolute relative error value for each blood glucose meter was calculated and ranged from 6.5% to 12.0%. CONCLUSIONS: More than 40% of evaluated SMBG systems meet the minimal accuracy criteria requirement of ISO 15197:2003. However, considering tighter criteria for accuracy of ±15%, only the Bionime Rightest GM550 meets this requirement. Because SMBG systems play a critical role in management of diabetes, manufacturers have to strive to improve accuracy and precision and to ensure the good quality of blood glucose meters and test strips.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2010.0223

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 8

  1. 10.1177/193229681000400201 · DOI
  2. 10.1056/NEJMoa011300 · DOI · Paper page
  3. 10.1177/193229681000400301 · DOI · Paper page
  4. 10.1016/j.cca.2008.12.029 · DOI
  5. 10.1089/dia.2007.0257 · DOI · Paper page
  6. DIN EN ISO 15197: In Vitro Diagnostic Test Systems Requirements for Blood Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus (ISO 15179:2003) Geneva: World Health Organization, 2003.
  7. 10.1177/193229680900300438 · DOI · Paper page
  8. 10.1093/clinchem/47.2.209 · DOI · Paper page

Cited by

See all 55

Metadata

Authors
Kuo, C.-Y., Hsu, C.-T., Ho, C.-S., Su, T.-E., Wu, M.-H., & Wang, C.-J.
Venue
Diabetes Technology & Therapeutics
Published
2011-05
Volume
13
Issue
5
Pages
596-600
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2141713744
Cited by
55
References
2
FWCI
6.35
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Precision Evaluation of Seven Self-Monitoring Blood Glucose Systems. https://app.cochat.ai/papers/10.1089/dia.2010.0223
The paper
Kuo, C.-Y., Hsu, C.-T., Ho, C.-S., Su, T.-E., Wu, M.-H., & Wang, C.-J. (2011). Accuracy and Precision Evaluation of Seven Self-Monitoring Blood Glucose Systems. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2010.0223

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.