Artificial Pancreas Using a Personalized Rule-Based Controller Achieves Overnight Normoglycemia in Patients with Type 1 Diabetes

Open access
Capel, Ismael, Rigla, Mercedes, García-Sáez, Gema, Rodríguez-Herrero, Agustín, Pons, Belén, Subías, David, García-García, Fernando, Gallach, Maria, Aguilar, Montserrat, Pérez-Gandía, Carmen, Gómez, Enrique J., Caixàs, Assumpta, Hernando, M. Elena · 2014 · Diabetes Technology & Therapeutics
Cited by 29

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: This study assessed the efficacy of a closed-loop (CL) system consisting of a predictive rule-based algorithm (pRBA) on achieving nocturnal and postprandial normoglycemia in patients with type 1 diabetes mellitus (T1DM). The algorithm is personalized for each patient's data using two different strategies to control nocturnal and postprandial periods. RESEARCH DESIGN AND METHODS: We performed a randomized crossover clinical study in which 10 T1DM patients treated with continuous subcutaneous insulin infusion (CSII) spent two nonconsecutive nights in the research facility: one with their usual CSII pattern (open-loop [OL]) and one controlled by the pRBA (CL). The CL period lasted from 10 p.m. to 10 a.m., including overnight control, and control of breakfast. Venous samples for blood glucose (BG) measurement were collected every 20 min. RESULTS: Time spent in normoglycemia (BG, 3.9-8.0 mmol/L) during the nocturnal period (12 a.m.-8 a.m.), expressed as median (interquartile range), increased from 66.6% (8.3-75%) with OL to 95.8% (73-100%) using the CL algorithm (P<0.05). Median time in hypoglycemia (BG, <3.9 mmol/L) was reduced from 4.2% (0-21%) in the OL night to 0.0% (0.0-0.0%) in the CL night (P<0.05). Nine hypoglycemic events (<3.9 mmol/L) were recorded with OL compared with one using CL. The postprandial glycemic excursion was not lower when the CL system was used in comparison with conventional preprandial bolus: time in target (3.9-10.0 mmol/L) 58.3% (29.1-87.5%) versus 50.0% (50-100%). CONCLUSIONS: A highly precise personalized pRBA obtains nocturnal normoglycemia, without significant hypoglycemia, in T1DM patients. There appears to be no clear benefit of CL over prandial bolus on the postprandial glycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2013.0229

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Capel, I., Rigla, M., García-Sáez, G., Rodríguez-Herrero, A., Pons, B., Subías, D., García-García, F., Gallach, M., Aguilar, M., Pérez-Gandía, C., Gómez, E. J., Caixàs, A., & Hernando, M. E.
Venue
Diabetes Technology & Therapeutics
Published
2014-03
Volume
16
Issue
3
Pages
172-179
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2080826621
Cited by
29
References
9
FWCI
3.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.