Individually Adaptive Artificial Pancreas in Subjects with Type 1 Diabetes: A One-Month Proof-of-Concept Trial in Free-Living Conditions
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: To evaluate the efficacy of a run-to-run (R2R) adaptive wearable artificial pancreas (AP) after 1 month of closed-loop glucose control in subjects with type 1 diabetes (T1D) under free-living conditions. Methods: Eighteen adults, who had previously completed a 1-month closed-loop study with a non-adaptive artificial pancreas (NA-AP), volunteered for an additional 1-month extension study in which the AP was equipped with an adaptive model predictive control algorithm (R2R-AP). Continuous glucose monitoring data were analyzed on an intention-to-treat basis by comparing the last week of R2R-AP versus the last week of NA-AP. The primary endpoint was the time in target range (3.9–10 mmol/L) over 24 h. Results: Time in target with R2R-AP is higher than with the NA-AP, although the increase was not significant: mean 66.90% (standard deviation: 13.34) versus 61.82% (11.12), P = 0.10. The increase was significant during the night: 74.01% (14.61) versus 64.31% (15.71), P = 0.03, and at wake-up time: median 92.43% (25th; 75th percentiles: 78.22; 99.53) versus 84.54% (57.14; 88.52), P = 0.02. Time above target (>10 mmol/L) during the whole day was 30.98% (13.22) versus 36.17% (11.53), P = 0.10. The decrease was significant during the night: 24.23% (15.03) versus 34.49% (16.25), P = 0.03, and at wake-up time: 7.57% (0.00; 14.29) versus 14.29% (8.25; 42.86), P = 0.05. Time spent below target (<3.9 mmol/L) was low and similar to the two treatments. Conclusions: R2R-AP improves glucose control over NA-AP in subjects with T1D during the night, and it maintains equivalent control performance during the day in a 1-month trial under free-living conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s081 · Cited by 5,974
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Self-citationHome Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211
Self-citationKovatchev, B., Cheng, P., Anderson, S. M., Pinsker, J. E., Boscari, F., Buckingham, B. A., Doyle, F. J., Hood, K. K., Brown, S. A., Breton, M. D., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0333 · Cited by 141
Self-citationRenard, E., Farret, A., Kropff, J., Bruttomesso, D., Messori, M., Place, J., Visentin, R., Calore, R., Toffanin, C., Di Palma, F., et al. (2016) · Diabetes Care · doi:10.2337/dc16-0008 · Cited by 104
Self-citationThe Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes
Kovatchev, B., Tamborlane, W. V., Cefalu, W. T., & Cobelli, C. (2016) · Diabetes Care · doi:10.2337/dc16-0824 · Cited by 95
Self-citation
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationThe UVA/Padova Type 1 Diabetes Simulator Goes From Single Meal to Single Day
Visentin, R., Campos-Náñez, E., Schiavon, M., Lv, D., Vettoretti, M., Breton, M., Kovatchev, B. P., Dalla Man, C., & Cobelli, C. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818757747 · Cited by 280
Self-citationToffanin, C., Magni, L., & Cobelli, C. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3075775 · Cited by 22
Self-citationCamerlingo, N., Vettoretti, M., Del Favero, S., Cappon, G., Sparacino, G., & Facchinetti, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0139 · Cited by 22
Metadata
- Authors
- Messori, M., Kropff, J., Del Favero, S., Place, J., Visentin, R., Calore, R., Toffanin, C., Di Palma, F., Lanzola, G., Farret, A., Boscari, F., Galasso, S., Avogaro, A., Keith-Hynes, P., Kovatchev, B. P., Bruttomesso, D., Magni, L., DeVries, J. H., Renard, E., Cobelli, C., & for the AP@home consortium
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2017-10
- Volume
- 19
- Issue
- 10
- Pages
- 560-571
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2749766521
- Cited by
- 59
- References
- 8
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.