Real-World Hypoglycemia Avoidance with a Continuous Glucose Monitoring System's Predictive Low Glucose Alert
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Programmable and fixed auditory and/or vibratory threshold alerts are essential features of real-time continuous glucose monitoring (rtCGM) systems that provide users time to intervene before the onset of clinical hypoglycemia or hyperglycemia. A sixth-generation rtCGM system from Dexcom, Inc. (G6) includes a new alert that is triggered when an algorithm predicts that an estimated glucose value ≤55 mg/dL will occur within 20 min, allowing users more time to act to avoid hypoglycemia. We examined whether this predictive low glucose alert provided added benefit to traditional low threshold alerts. METHODS: We analyzed glucose values from an anonymized sample of 1424 patients who transitioned to G6 from the preceding fifth-generation system (G5) with no predictive alert. Users with the low threshold alert setting of 70 or 80 mg/dL were evaluated separately. Receiver users, those who disabled the predictive low glucose alert, or those with <30 days of data immediately before or after the transition to G6 were excluded. RESULTS: Percent time <54, ≤55, <70, and >250 mg/dL fell significantly after the transition to G6, independent of low threshold alert setting. Time in range improved for G6 users with a low threshold alert setting of 70 mg/dL. CONCLUSIONS: Advance warning provided by predictive low glucose alerts may further reduce hypoglycemia among rtCGM-experienced users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationDefining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652 · cited 1×
“23,24 The current data demonstrate that the incorporation of a predictive low glucose alert into a G6 CGM system further diminishes hypoglycemia exposure, significantly reducing hypoglycemia relative to a CGM system without the predictive alert, independent of threshold alert setting.”
BackgroundSelf-citationHeinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Hypoglycemia, functional brain failure, and brain death.
Cryer, P. E. (2007) · Journal of Clinical Investigation · doi:10.1172/jci31669 · Cited by 363
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
Forlenza, G. P., Li, Z., Buckingham, B. A., Pinsker, J. E., Cengiz, E., Wadwa, R. P., Ekhlaspour, L., Church, M. M., Weinzimer, S. A., Jost, E., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0771 · Cited by 246
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245 · cited 1×
“Hypoglycemia exposure was evaluated as the percentage of EGVs £55 mg/dL, to match the ULS alert setting, as well as the percentage of EGVs <54 mg/dL, to match consensus guidelines.(22) P-values were computed using a two-sided Welch’s unequal variance t-test between population means.”
Method
Cited by
Faulds, E. R., Boutsicaris, A., Sumner, L., Jones, L., McNett, M., Smetana, K. S., May, C. C., Buschur, E., Exline, M. C., Ringel, M. D., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab409 · Cited by 71
Real-World Data from the First U.S. Commercial Users of an Implantable Continuous Glucose Sensor
Sanchez, P., Ghosh-Dastidar, S., Tweden, K. S., & Kaufman, F. R. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0234 · Cited by 40
“…et al. with predictive alarms, the mean TIR was 61%–63% when the low threshold was set at 70 mg/dL and 57%–58.7% with the low threshold at 80 mg/dL. 16 In the STAR 3 study, which evaluated a sensor augmented pump system, 7 and in the arm of the DIAMOND study that evaluated CGM with CSII, 17 the…”
InfluentialContinuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
“More recently, trials specifically investigating hypoglycaemia in patients with diabetes have shown good improvements,(36) particularly overnight(37) and when using predictive alarms.(38)”
BackgroundEnhancing the Capabilities of Continuous Glucose Monitoring With a Predictive App
Herrero, P., Andorrà, M., Babion, N., Bos, H., Koehler, M., Klopfenstein, Y., Leppäaho, E., Lustenberger, P., Peak, A., Ringemann, C., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267818 · Cited by 31
Acciaroli, G., Welsh, J. B., & Akturk, H. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820982584 · Cited by 27
Self-citation
Metadata
- Authors
- Puhr, S., Derdzinski, M., Welsh, J. B., Parker, A. S., Walker, T., & Price, D. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2019-04
- Volume
- 21
- Issue
- 4
- Pages
- 155-158
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2924516949
- Cited by
- 78
- References
- 13
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-World Hypoglycemia Avoidance with a Continuous Glucose Monitoring System's Predictive Low Glucose Alert. https://app.cochat.ai/papers/10.1089/dia.2018.0359
- The paper
- Puhr, S., Derdzinski, M., Welsh, J. B., Parker, A. S., Walker, T., & Price, D. A. (2019). Real-World Hypoglycemia Avoidance with a Continuous Glucose Monitoring System's Predictive Low Glucose Alert. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2018.0359
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.