Cited by 9Diabetes Management and ResearchDiabetes Management and EducationDiabetes and associated disorders

Frequency of Rebound Hyperglycemia in Adults with Type 1 Diabetes Treated with Different Insulin Delivery Modalities

Open access
Tidemand, Katrine Grønbæk, Laugesen, Christian, Ranjan, Ajenthen Gayathri, Skovhus, Liv Boelskifte, Nørgaard, Kirsten·2025·Diabetes Technology & Therapeutics

Abstract

Background: For people with type 1 diabetes (T1D), ensuring fast and effective recovery from hypoglycemia while avoiding posthypoglycemic hyperglycemia (rebound hyperglycemia, RH) can be challenging. The objective of this study was to investigate the frequency of RH across different treatment modalities and its impact on glycemic control. Methods: This cross-sectional real-world study included adults with T1D using continuous glucose monitoring and attending the outpatient clinic at Steno Diabetes Center Copenhagen. RH was defined as ≥1 sensor glucose value (SG) >10.0 mmol/L (180 mg/dL) starting within 2 h of an antecedent SG <3.9 mmol/L (70 mg/dL). The severity of the RH events was calculated as area under the curve (AUC) and separately for users of multiple daily injections (MDIs), unintegrated insulin pumps, sensor augmented pumps (SAPs), and automated insulin delivery (AID), respectively. Results: Across the four groups, SAP and AID users had the highest incidence of RH (2.06 ± 1.65 and 2.08 ± 1.49 events per week, respectively) and a similar percentage of hypoglycemic events leading to RH events (41.3 ± 22.8% and 39.6 ± 20.1%, respectively). The AID users with RH events were significantly shorter compared with MDI users (122 ± 72 vs. 185 ± 135 min; P < 0.0001). Overall, severity of RH was inversely associated with more advanced technology ( P < 0.001) and inversely associated ( P < 0.001) with time in target range (TIR). Conclusions: Groups with insulin suspension features experienced the highest frequency of RH; however, AID users tended to experience shorter and less severe RH events. The association between the severity of RH events and TIR suggests that RH should be assessed and used in the guidance of hypoglycemia management.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2024.0134

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Tidemand, K. G., Laugesen, C., Ranjan, A. G., Skovhus, L. B., & Nørgaard, K.
Affiliations
  • Copenhagen University Hospital (DK)
  • University of Copenhagen (DK)
Venue
Diabetes Technology & Therapeutics
Published
2025-01
Volume
27
Issue
1
Pages
60-65
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W4400977738
Cited by
9
References
12
Citations by year
2026: 4 · 2025: 5
FWCI
2.97
Type
journal article
Language
en
Open access
Locations
  • Diabetes Technology & Therapeutics (publishedVersion)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
Funders
Steno Diabetes Center Copenhagen (SDCC 3.E Technology)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
rebound hyperglycemia, type 1 diabetes, hypoglycemia, artificial pancreas, sensor-augmented pump, insulin pump, multiple daily insulin injections, continuous glucose monitoring, time in range, glycemic control, hypoglycemia management
MeSH terms
Glycemic Control, Adult, Blood Glucose, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Female, Humans, Hyperglycemia, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review