The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Endothelialized Microvasculature Based on a Biodegradable Elastomer
Abstract
Vital organs maintain dense microvasculature to sustain the proper function of their cells. For tissue- engineered organs to function properly, artificial capillary networks must be developed. We have microfabricated capillary networks with a biodegradable and biocompatible elastomer, poly(glycerol sebacate) (PGS). We etched capillary patterns onto silicon wafers by standard micro-electromechanical systems (MEMS) techniques. The resultant silicon wafers served as micromolds for the devices. We bond the patterned PGS film with a flat film to create capillary networks that were perfused with a syringe pump at a physiological flow rate. The devices were endothelialized under flow conditions, and part of the lumens reached confluence within 14 days of culture. This approach may lead to tissue-engineered microvasculature that is critical in vital organs engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
Self-citationSELF-REGULATION OF GROWTH IN THREE DIMENSIONS
Folkman, J., & Hochberg, M. (1973) · The Journal of Experimental Medicine · doi:10.1084/jem.138.4.745 · Cited by 829
Cited by
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Stimuli-responsive hydrogels in drug delivery and tissue engineering
Sood, N., Bhardwaj, A., Mehta, S., & Mehta, A. (2016) · Drug Delivery · doi:10.3109/10717544.2014.940091 · Cited by 426
Cell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320
Vascularization—The Conduit to Viable Engineered Tissues
Kaully, T., Kaufman-Francis, K., Lesman, A., & Levenberg, S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0193 · Cited by 317
Vascularized Bone Tissue Engineering: Approaches for Potential Improvement
Nguyen, L. H., Annabi, N., Nikkhah, M., Bae, H., Binan, L., Park, S., Kang, Y., Yang, Y., & Khademhosseini, A. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0012 · Cited by 313
Metadata
- Authors
- Fidkowski, C., Kaazempur-Mofrad, M. R., Borenstein, J., Vacanti, J. P., Langer, R., & Wang, Y.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2005-01
- Volume
- 11
- Issue
- 1-2
- Pages
- 302-309
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2017482231
- Cited by
- 343
- References
- 2
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endothelialized Microvasculature Based on a Biodegradable Elastomer. https://app.cochat.ai/papers/10.1089/ten.2005.11.302
- The paper
- Fidkowski, C., Kaazempur-Mofrad, M. R., Borenstein, J., Vacanti, J. P., Langer, R., & Wang, Y. (2005). Endothelialized Microvasculature Based on a Biodegradable Elastomer. Tissue Engineering. https://doi.org/10.1089/ten.2005.11.302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.