CoChat

Design and Characterization of Poly(Ethylene Glycol) Photopolymerizable Semi-Interpenetrating Networks for Chondrogenesis of Human Mesenchymal Stem Cells

Buxton, Amanda N., Zhu, Junmin, Marchant, Roger, West, Jennifer L., Yoo, Jung U., Johnstone, Brian · 2007 · Tissue Engineering
Cited by 154

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Mesenchymal stem cells (MSCs) are used extensively in cartilage tissue engineering. We have developed a photopolymerizable poly(ethylene glycol diacrylate) (PEGDA) and poly(ethylene glycol) (PEG) semi-interpenetrating network that facilitates the in vitro chondrogenesis of human MSCs (hMSCs). Network parameters were altered and tested for their effects on subsequent matrix elaboration. The mesh size, calculated for each network based on equilibrium swelling ratios, was larger with lower PEGDA:PEG ratios and with higher PEGDA molecular weight. Changes in xi correlated with changes in extracellular matrix content and deposition in hMSC-seeded networks cultured in vitro for 6 weeks in defined chondrogenic medium. Networks constructed with PEGDA (6 kDa) and PEG (88 kDa) at 1:2 displayed intercellular deposition of proteoglycan. Furthermore, their proteoglycan contents were significantly higher than with PEGDA (6 kDa) hydrogels constructed without the PEG component and those constructed at a PEGDA:PEG ratio of 2:1, which both exhibited pericellular proteoglycan deposition. However, networks constructed with PEGDA (12 and 20 kDa) and PEG (88 kDa) exhibited intercellular deposition of proteoglycan regardless of the ratio employed. Collagen content was lower in networks constructed with PEGDA (12 and 20 kDa) and PEG (88 kDa) at a ratio of 1:2 than in those fabricated at the same PEGDA molecular weights at a ratio of 2:1. This study demonstrated that semi-interpenetrating network parameters influence not only extracellular matrix content, but also the deposition of the matrix molecules by hMSCs undergoing chondrogenesis. It is important that these parameters be considered carefully when creating scaffolds for tissue-engineered cartilage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.2007.0075

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Buxton, A. N., Zhu, J., Marchant, R., West, J. L., Yoo, J. U., & Johnstone, B.
Venue
Tissue Engineering
Published
2007-10
Volume
13
Issue
10
Pages
2549-2560
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2094069558
Cited by
154
References
2
FWCI
4.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.