The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Hypoxia in Static and Dynamic 3D Culture Systems for Tissue Engineering of Bone
Abstract
Tissue engineering of sizeable cell-scaffold constructs is limited by gradients in tissue quality from the periphery toward the center. Because homogenous delivery of oxygen to three-dimensional (3D) cell cultures remains an unsolved challenge, we hypothesized that uneven oxygen supply may impede uniform cellular growth on scaffolds. In this study we challenged static and dynamic 3D culture systems designed for bone tissue engineering applications with a well-growing subclone of MC3T3-E1 preosteoblasts and continuously measured the oxygen concentrations in the center of cell-seeded scaffolds and in the surrounding medium. After as little as 5 days in static culture, central oxygen concentrations dropped to 0%. Subsequently, cells died in central regions of the scaffold but not in its periphery, where oxygen levels were approximately 4%. The use of perfusion bioreactors successfully prevented cell death, yet central oxygen concentrations did not rise above 4%. We conclude that 3D culture in vitro is associated with relevant oxygen gradients, which can be the cause of inhomogeneous tissue quality. Perfusion bioreactors prevent cell death but they do not entirely eliminate 3D culture-associated oxygen gradients. Therefore, we advise continuous oxygen monitoring of 3D culture systems to ensure tissue quality throughout engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ENGINEERING PRINCIPLES OF CLINICAL CELL-BASED TISSUE ENGINEERING
MUSCHLER, G. F., NAKAMOTO, C., & GRIFFITH, L. G. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200407000-00029 · Cited by 878
Distribution of hematopoietic stem cells in the bone marrow according to regional hypoxia
Parmar, K., Mauch, P., Vergilio, J.-A., Sackstein, R., & Down, J. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0701152104 · Cited by 867
Wang, Y., Wan, C., Deng, L., Liu, X., Cao, X., Gilbert, S. R., Bouxsein, M. L., Faugere, M.-C., Guldberg, R. E., Gerstenfeld, L. C., et al. (2007) · Journal of Clinical Investigation · doi:10.1172/jci31581 · Cited by 733
Bancroft, G. N., Sikavitsas, V. I., van den Dolder, J., Sheffield, T. L., Ambrose, C. G., Jansen, J. A., & Mikos, A. G. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202296599 · Cited by 693
Oxygen gradients correlate with cell density and cell viability in engineered cardiac tissue
Radisic, M., Malda, J., Epping, E., Geng, W., Langer, R., & Vunjak‐Novakovic, G. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20722 · Cited by 399
Bioreactors for tissue mass culture: Design, characterization, and recent advances
Martin, Y., & Vermette, P. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.057 · Cited by 390
Bancroft, G. N., Sikavitsas, V. I., & Mikos, A. G. (2003) · Tissue Engineering · doi:10.1089/107632703322066723 · Cited by 371
Oxygen gradients in tissue‐engineered Pegt/Pbt cartilaginous constructs: Measurement and modeling
Malda, J., Rouwkema, J., Martens, D. E., le Comte, E. P., Kooy, F. K., Tramper, J., van Blitterswijk, C. A., & Riesle, J. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20038 · Cited by 325
Perfusion Improves Tissue Architecture of Engineered Cardiac Muscle
Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G. (2002) · Tissue Engineering · doi:10.1089/107632702753724950 · Cited by 323
Replacement of an Avulsed Phalanx with Tissue-Engineered Bone
Vacanti, C. A., Bonassar, L. J., Vacanti, M. P., & Shufflebarger, J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105173442004 · Cited by 307
Malladi, P., Xu, Y., Chiou, M., Giaccia, A. J., & Longaker, M. T. (2006) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00415.2005 · Cited by 301
Hypoxia affects mesenchymal stromal cell osteogenic differentiation and angiogenic factor expression
Potier, E., Ferreira, E., Andriamanalijaona, R., Pujol, J.-P., Oudina, K., Logeart-Avramoglou, D., & Petite, H. (2007) · Bone · doi:10.1016/j.bone.2006.11.024 · Cited by 294
The Roles of Hypoxia in the In Vitro Engineering of Tissues
Malda, J., Klein, T. J., & Upton, Z. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0417 · Cited by 282
Oxygen Tension of Healing Fractures in the Rabbit
BRIGHTON, C. T., & KREBS, A. G. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254020-00010 · Cited by 243
Determination of oxygen gradients in engineered tissue using a fluorescent sensor
Kellner, K., Liebsch, G., Klimant, I., Wolfbeis, O. S., Blunk, T., Schulz, M. B., & Göpferich, A. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10352 · Cited by 238
Potier, E., Ferreira, E., Meunier, A., Sedel, L., Logeart-Avramoglou, D., & Petite, H. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0325 · Cited by 224
Salim, A., Nacamuli, R. P., Morgan, E. F., Giaccia, A. J., & Longaker, M. T. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m403715200 · Cited by 221
Malda, J., Woodfield, T. B. F., van der Vloodt, F., Kooy, F. K., Martens, D. E., Tramper, J., Blitterswijk, C. A. V., & Riesle, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.028 · Cited by 200
John, G. T., Klimant, I., Wittmann, C., & Heinzle, E. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10534 · Cited by 199
Semenza, G. L. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2006.033498 · Cited by 194
Sikavitsas, V. I., Bancroft, G. N., Lemoine, J. J., Liebschner, M. A. K., Dauner, M., & Mikos, A. G. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8963-x · Cited by 193
Wendt, D. J., Ströbel, S., Jakob, M., John, G. T., & Martín, I. (2006) · Biorheology · doi:10.1177/0006355x2006043003004030 · Cited by 147
Deshpande, R. R., & Heinzle, E. (2004) · Biotechnology Letters · doi:10.1023/b:bile.0000024101.57683.6d · Cited by 126
Guarino, R. D., Dike, L. E., Haq, T. A., Rowley, J. A., Pitner, J. B., & Timmins, M. R. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20072 · Cited by 118
Arkudas, A., Beier, J. P., Heidner, K., Tjiawi, J., Polykandriotis, E., Srour, S., Stürzl, M., Horch, R. E., & Kneser, U. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0387 · Cited by 112
Bioreactors for Tissues of the Musculoskeletal System
Abousleiman, R. I., & Sikavitsas, V. I. (2007) · Springer eBooks · doi:10.1007/978-0-387-34133-0_17 · Cited by 58
Human mesenchymal stem cells at the single‐cell level: simultaneous seven‐colour immunofluorescence
Schieker, M., Pautke, C., Haasters, F., Schieker, J., Docheva, D., Böcker, W., Guelkan, H., Neth, P., Jochum, M., & Mutschler, W. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00716.x · Cited by 51
Self-citationDie Überbrückung von posttraumatischen Knochendefekten: Bewährtes und Neues
Schieker, M., & Mutschler, W. (2006) · Der Unfallchirurg · doi:10.1007/s00113-006-1152-z · Cited by 48
Self-citationUse of Micropathways to Improve Oxygen Transport in a Hepatic System
McClelland, R., & Coger, R. N. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.429657 · Cited by 46
Aro, H. T., Eerola, E., Aho, A. J., & Niinikoski, J. (1984) · Journal of Surgical Research · doi:10.1016/0022-4804(84)90181-1 · Cited by 33
Hypoxia regulates PGE2 release and EP1 receptor expression in osteoblastic cells
Lee, C. M., Genetos, D. C., You, Z., & Yellowley, C. E. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.21017 · Cited by 31
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Deconstructing the third dimension – how 3D culture microenvironments alter cellular cues
Baker, B. M., & Chen, C. S. (2012) · Journal of Cell Science · doi:10.1242/jcs.079509 · Cited by 1,760
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Zhu, G., Zhang, T., Chen, M., Yao, K., Huang, X., Zhang, B., Li, Y., Liu, J., Wang, Y., & Zhao, Z. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.03.043 · Cited by 494
Frith, J. E., Thomson, B., & Genever, P. G. (2010) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2009.0432 · Cited by 475
Metadata
- Authors
- Volkmer, E., Drosse, I., Otto, S., Stangelmayer, A., Stengele, M., Kallukalam, B. C., Mutschler, W., & Schieker, M.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2008-08
- Volume
- 14
- Issue
- 8
- Pages
- 1331-1340
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2078677737
- Cited by
- 285
- References
- 31
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.