Human Induced Pluripotent Stem-Cardiac-Endothelial-Tumor-on-a-Chip to Assess Anticancer Efficacy and Cardiotoxicity
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Cancer remains a leading health threat in the United States, and cardiovascular drug toxicity is a primary cause to eliminate a drug from FDA approval. As a result, the demand to develop new anticancer drugs without cardiovascular toxicity is high. Human induced pluripotent stem (iPS) cell-derived tissue chips provide potentially a cost-effective preclinical drug testing platform, including potential avenues for personalized medicine. We have developed a three-dimensional microfluidic device that simultaneously cultures tumor cell spheroids with iPS-derived cardiomyocytes (iPS-CMs) and iPS-derived endothelial cells (iPS-EC). The iPS-derived cells include a GCaMP6 fluorescence reporter to allow real-time imaging to monitor intracellular calcium transients. The multiple-chambered tissue chip features electrodes for pacing of the cardiac tissue to assess cardiomyocyte function such as the maximum capture rate and conduction velocity. We measured the inhibition concentration (IC 50 ) of the anticancer drugs, Doxorubicin (0.1 μM) and Oxaliplatin (4.2 μM), on the tissue chip loaded with colon cancer cells (SW620). We simultaneously evaluated the cardiotoxicity of these anticancer drugs by assessing the drug effect on the spontaneous beat frequency and conduction velocity of iPS-derived cardiac tissue. Consistent with in vivo observations, Doxorubicin reduced the spontaneous beating rate and maximum capture rate at or near the IC 50 (0.04 and 0.22 μM, respectively), whereas the toxicity of Oxaliplatin was only observed at concentrations beyond the IC 50 (33 and 9.9 μM, respectively). Our platform demonstrates the feasibility to simultaneously assess cardiac toxicity and antitumor effects of drugs and could be used to enhance personalized drug testing safety and efficacy. Impact statement Drug development using murine models for preclinical testing is no longer adequate nor acceptable both financially for the pharmaceutical industry as well as for generalized or personalized assessment of safety and efficacy. Innovative solutions using human cells and tissues provide exciting new opportunities. In this study, we report on the creation of a 3D microfluidic device that simultaneously cultures human tumor cell spheroids with cardiomyocytes and endothelial cells derived from the same induced pluripotent stem cell line. The platform provides the opportunity to assess efficacy of anticancer agents while simultaneously screening for potential cardiovascular toxicity in a format conducive for personalized medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lian, X., Hsiao, C., Wilson, G., Zhu, K., Hazeltine, L. B., Azarin, S. M., Raval, K. K., Zhang, J., Kamp, T. J., & Palecek, S. P. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200250109 · Cited by 1,717
Zanoni, M., Piccinini, F., Arienti, C., Zamagni, A., Santi, S., Polico, R., Bevilacqua, A., & Tesei, A. (2016) · Scientific Reports · doi:10.1038/srep19103 · Cited by 1,144
Biowire: a platform for maturation of human pluripotent stem cell–derived cardiomyocytes
Nunes, S. S., Miklas, J. W., Liu, J., Aschar-Sobbi, R., Xiao, Y., Zhang, B., Jiang, J., Massé, S., Gagliardi, M., Hsieh, A., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2524 · Cited by 952
Drug-induced oxidative stress and toxicity
Deavall, D. G., Martin, E. A., Horner, J. M., & Roberts, R. (2012) · Journal of Toxicology · doi:10.1155/2012/645460 · Cited by 689
Multi-tissue interactions in an integrated three-tissue organ-on-a-chip platform
Skardal, A., Murphy, S. V., Devarasetty, M., Mead, I., Kang, H.-W., Seol, Y.-J., Shrike Zhang, Y., Shin, S.-R., Zhao, L., Aleman, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08879-x · Cited by 623
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387 · cited 2×
“We and others have presented more complex 3D models of the human microcirculation, including the use of these systems to examine tumor drug sensitivity.(1,7,25) These systems generally involve the creation of 3D vascular networks that form through the process of vasculogenesis or angiogenesis and have the advantage of…”
BackgroundSelf-citationA vascularized and perfused organ-on-a-chip platform for large-scale drug screening applications
Phan, D. T. T., Wang, X., Craver, B. M., Sobrino, A., Zhao, D., Chen, J. C., Lee, L. Y. N., George, S. C., Lee, A. P., & Hughes, C. C. W. (2017) · Lab on a Chip · doi:10.1039/c6lc01422d · Cited by 325 · cited 2×
“While twodimensional (2D) cell culture systems remain the mainstay due to simplicity, reproducibility, and affordability, these systems do not capture the rich cell–cell and cell–matrix interactions of the three-dimensional (3D) in vivo tissue microenvironment that has been shown to be crucial to predict drug response…”
BackgroundSelf-citationShirure, V. S., Bi, Y., Curtis, M. B., Lezia, A., Goedegebuure, M. M., Goedegebuure, S. P., Aft, R., Fields, R. C., & George, S. C. (2018) · Lab on a Chip · doi:10.1039/c8lc00596f · Cited by 316 · cited 1×
“Recent studies have addressed this issue by developing tumor-on-a-chip systems with a vascular supply.(6) Interestingly, drug responses of tumor-on-a-chip systems with and without vasculature have been significantly different.”
BackgroundSelf-citation
Cited by
Scaffold-based 3D cell culture models in cancer research
Abuwatfa, W. H., Pitt, W. G., & Husseini, G. A. (2024) · Journal of Biomedical Science · doi:10.1186/s12929-024-00994-y · Cited by 324
Organ-on-a-chip model of vascularized human bone marrow niches
Glaser, D. E., Curtis, M. B., Sariano, P. A., Rollins, Z. A., Shergill, B. S., Anand, A., Deely, A. M., Shirure, V. S., Anderson, L., Lowen, J. M., et al. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2021.121245 · Cited by 146
Self-citationDe Masi, C., Spitalieri, P., Murdocca, M., Novelli, G., & Sangiuolo, F. (2020) · Human Genomics · doi:10.1186/s40246-020-00276-2 · Cited by 91
Extracellular matrix-inspired biomaterials for wound healing
Hosty, L., Heatherington, T., Quondamatteo, F., & Browne, S. (2024) · Molecular Biology Reports · doi:10.1007/s11033-024-09750-9 · Cited by 63
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Metadata
- Authors
- Weng, K.-C., Kurokawa, Y. K., Hajek, B. S., Paladin, J. A., Shirure, V. S., & George, S. C.
- Venue
- Tissue Engineering Part C: Methods
- Publisher
- SAGE Publications
- Published
- 2020-01-01
- Volume
- 26
- Issue
- 1
- Pages
- 44-55
- ISSN
- 1937-3384 (ISSN-L)
- 1937-3392
- OpenAlex
- W2992548516
- Cited by
- 80
- References
- 14
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Induced Pluripotent Stem-Cardiac-Endothelial-Tumor-on-a-Chip to Assess Anticancer Efficacy and Cardiotoxicity. https://app.cochat.ai/papers/10.1089/ten.tec.2019.0248
- The paper
- Weng, K.-C., Kurokawa, Y. K., Hajek, B. S., Paladin, J. A., Shirure, V. S., & George, S. C. (2020). Human Induced Pluripotent Stem-Cardiac-Endothelial-Tumor-on-a-Chip to Assess Anticancer Efficacy and Cardiotoxicity. Tissue Engineering Part C: Methods. https://doi.org/10.1089/ten.tec.2019.0248
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.