Cited by 3253D Printing in Biomedical ResearchMicrofluidic and Capillary Electrophoresis ApplicationsTissue Engineering and Regenerative Medicine

A vascularized and perfused organ-on-a-chip platform for large-scale drug screening applications

Open access
Phan, Duc T. T., Wang, Xiaolin, Craver, Brianna M., Sobrino, Agua, Zhao, Da, Chen, Jerry C., Lee, Lilian Y. N., George, Steven C. +2 more·2017·Lab on a Chip

Abstract

A vascularized, perfused organ-on-a-chip platform suitable for large-scale drug efficacy/toxicity screening.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c6lc01422d

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • This 3D VMT platform is suitable for efficacy/toxicity screening of various tissues under more complex conditions than physiological environments.

    “This 3D platform is suitable for the efficacy/toxicity screening of various tissues under more complex conditions than physiological environments.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [19]Papaioannou T and Stefanadis C, Hellenic J Cardiol, 2005, 46, 9– 15. 15807389
  2. [20]McDonald D and Baluk P, Cancer Res, 2002, 62, 5381– 5385. 12235011

Cited by

Sorted by citations

Authors
Phan, D. T. T., Wang, X., Craver, B. M., Sobrino, A., Zhao, D., Chen, J. C., Lee, L. Y. N., George, S. C., Lee, A. P., & Hughes, C. C. W.
Affiliations
  • University of California, Irvine (US)
  • Shanghai Jiao Tong University (CN)
  • Washington University in St. Louis (US)
Corresponding author
  • Lee, Abraham P.
  • Hughes, Christopher C. W.
Venue
Lab on a Chip
Published
2017
Volume
17
Issue
3
Pages
511-520
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2569855725
Cited by
325
References
20
Citations by year
2026: 17 · 2025: 30 · 2024: 38 · 2023: 38 · 2022: 42 · 2021: 49 · 2020: 42 · 2019: 26 · 2018: 36 · 2017: 7
FWCI
13.63
Type
journal article
Language
en
Open access
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
National Institutes of Health (P30/A062203, R01/CA180122, UH3/TR000481)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
organ-on-a-chip, microphysiological systems, 3D organ models, angiogenesis inhibitors, anticancer agents, drug screening, drug toxicity
MeSH terms
Antineoplastic Agents, Drug Evaluation, Preclinical, Equipment Design, Humans, Neoplasms, Experimental, Neovascularization, Pathologic, Gene Expression Regulation, Neoplastic, Cell Culture Techniques, Gene Expression Profiling, Microfluidic Analytical Techniques, Tissue Array Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review