X-ray Tomography Generates 3-D Reconstructions of the Yeast, Saccharomyces cerevisiae , at 60-nm Resolution
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We examined the yeast, Saccharomyces cerevisiae, using X-ray tomography and demonstrate unique views of the internal structural organization of these cells at 60-nm resolution. Cryo X-ray tomography is a new imaging technique that generates three-dimensional (3-D) information of whole cells. In the energy range of X-rays used to examine cells, organic material absorbs approximately an order of magnitude more strongly than water. This produces a quantifiable natural contrast in fully hydrated cells and eliminates the need for chemical fixatives or contrast enhancement reagents to visualize cellular structures. Because proteins can be localized in the X-ray microscope using immunogold labeling protocols (Meyer-Ilse et al., 2001. J. Microsc. 201, 395–403), tomography enables 3-D molecular localization. The time required to collect the data for each cell shown here was <15 min and has recently been reduced to 3 min, making it possible to examine numerous yeast and to collect statistically significant high-resolution data. In this video essay, we show examples of 3-D tomographic reconstructions of whole yeast and demonstrate the power of this technology to obtain quantifiable information from whole, hydrated cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional organization of the yeast proteome by systematic analysis of protein complexes
Gavin, A.-C., Bösche, M., Krause, R., Grandi, P., Marzioch, M., Bauer, A., Schultz, J., Rick, J. M., Michon, A.-M., Cruciat, C.-M., et al. (2002) · Nature · doi:10.1038/415141a · Cited by 4,759
Systematic identification of protein complexes in Saccharomyces cerevisiae by mass spectrometry
Ho, Y., Gruhler, A., Heilbut, A., Bader, G. D., Moore, L., Adams, S.-L., Millar, A., Taylor, P., Bennett, K., Boutilier, K., et al. (2002) · Nature · doi:10.1038/415180a · Cited by 3,601
SPIDER and WEB: Processing and Visualization of Images in 3D Electron Microscopy and Related Fields
Frank, J., Radermacher, M., Penczek, P., Zhu, J., Li, Y., Ladjadj, M., & Leith, A. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0030 · Cited by 2,027
Macromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Subcellular localization of the yeast proteome
Kumar, A., Agarwal, S., Heyman, J. A., Matson, S., Heidtman, M., Piccirillo, S., Umansky, L., Drawid, A., Jansen, R., Liu, Y., et al. (2002) · Genes & Development · doi:10.1101/gad.970902 · Cited by 739
Marsh, B. J., Mastronarde, D. N., Buttle, K. F., Howell, K. E., & McIntosh, J. R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051631998 · Cited by 356
Electron tomography of molecules and cells
Baumeister, W. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(98)01423-8 · Cited by 343
O’Toole, E. T., Winey, M., & McIntosh, J. R. (1999) · Molecular Biology of the Cell · doi:10.1091/mbc.10.6.2017 · Cited by 273
Electron Tomography of Ice-Embedded Prokaryotic Cells
Grimm, R., Singh, H., Rachel, R., Typke, D., Zillig, W., & Baumeister, W. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74028-7 · Cited by 209
High resolution protein localization using soft X‐ray microscopy
Meyer‐Ilse, W., Hamamoto, D., Nair, A., Lelièvre, S. A., Denbeaux, G., Johnson, L., Pearson, A. L., Yager, D., Legros, M. A., & Larabell, C. A. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00845.x · Cited by 197
Self-citationProtein complexes take the bait
Kumar, A., & Snyder, M. P. (2002) · Nature · doi:10.1038/415123a · Cited by 153
High-performance electron tomography of complex biological specimens
Fernández, J., Lawrence, A. F., Roca, J., García, I., Ellisman, M. H., & Carazo, J. M. (2002) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00017-5 · Cited by 88
Martone, M. E., Deerinck, T. J., Yamada, N., Bushong, E. A., & Ellisman, M. H. (2000) · Journal of Histotechnology · doi:10.1179/his.2000.23.3.261 · Cited by 49
Cited by
Metscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Sakdinawat, A., & Attwood, D. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.267 · Cited by 728
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Metscher, B. D. (2009) · Developmental Dynamics · doi:10.1002/dvdy.21857 · Cited by 607
Metadata
- Authors
- Larabell, C. A., & Le Gros, M. A.
- Venue
- Molecular Biology of the Cell
- Published
- 2004-03
- Volume
- 15
- Issue
- 3
- Pages
- 957-962
- ISSN
- 1059-1524 (ISSN-L)
- 1939-4586
- OpenAlex
- W2098499024
- Cited by
- 282
- References
- 13
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.