Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Review of Current Advances in Serologic Testing for COVID-19

Open access
Espejo, Andrea P, Akgun, Yamac, Al Mana, Abdulaziz F, Tjendra, Youley, Millan, Nicolas C, Gomez-Fernandez, Carmen, Cray, Carolyn · 2020 · American Journal of Clinical Pathology

Abstract

Objectives: To examine and summarize the current literature on serologic methods for the detection of antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: A literature review was performed using searches in databases including PubMed, medRxiv, and bioRxiv. Thirty-two peer-reviewed papers and 23 preprints were examined. Results: The studies included lateral flow immunoassay, enzyme-linked immunosorbent assay, chemiluminescence immunoassay, and neutralizing antibody assays. The use of all major SARS-CoV-2 antigens was demonstrated to have diagnostic value. Assays measuring total antibody reactivity had the highest sensitivity. In addition, all the methods provided opportunities to characterize the humoral immune response by isotype. The combined use of IgM and IgG detection resulted in a higher sensitivity than that observed when detecting either isotype alone. Although IgA was rarely studied, it was also demonstrated to be a sensitive marker of infection, and levels correlated with disease severity and neutralizing activity. Conclusions: The use of serologic testing, in conjunction with reverse transcription polymerase chain reaction testing, was demonstrated to significantly increase the sensitivity of detection of patients infected with SARS-CoV-2. There was conflicting evidence regarding whether antibody titers correlated with clinical severity. However, preliminary investigations indicated some immunoassays may be a surrogate for the prediction of neutralizing antibody titers and the selection of recovered patients for convalescent serum donation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ajcp/aqaa112

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 167

Metadata

Authors
Espejo, A. P., Akgun, Y., Al Mana, A. F., Tjendra, Y., Millan, N. C., Gomez-Fernandez, C., & Cray, C.
Venue
American Journal of Clinical Pathology
Published
2020-06-25
Volume
154
Issue
3
Pages
293-304
ISSN
  • 0002-9173 (ISSN-L)
  • 1943-7722
OpenAlex
W3037076666
Cited by
167
References
8
FWCI
4.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review of Current Advances in Serologic Testing for COVID-19. https://app.cochat.ai/papers/10.1093/ajcp/aqaa112
The paper
Espejo, A. P., Akgun, Y., Al Mana, A. F., Tjendra, Y., Millan, N. C., Gomez-Fernandez, C., & Cray, C. (2020). Review of Current Advances in Serologic Testing for COVID-19. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/aqaa112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.